journal article·2019-03

Simulation and experimental study of asymmetric split and recombine micromixer with D‐shaped sub‐channels

Xiuhua He, Tian Xia, Linfeng Gao, Zhidan Deng, Benjamin B. Uzoejinwa

Micro & Nano Letters· Volume 14· Issue 3
Publisher page

Abstract

An effective passive micromixer based on the principles of asymmetric split and recombine has been designed, developed, and investigated to enhance the mixing performance of the micromixer in a microfluidic system. The effects of geometrical parameters and the number of mixing units on mixing performance were studied at different Reynolds (Re) number (ranging from 1 to 80) via CFD software ANSYS CFX. The results revealed that the preferable number of mixing units is 6, and the optimal direction of reducer is opposite to the main channel flow; the D‐shaped mixing channel forces the mixed fluid to produce the extended vortex and Dean vortices simultaneously which caused a strong collision at the confluence of fluids, thus leading to the superposition and enhancement of the vortex system; when Re number is 80 and the width ratio of mixing channel W 2/ W 3 = 1, the mixing efficiency of micromixer can exceed 95%.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Innovative Microfluidic and Catalytic Techniques Innovation · Microfluidic and Bio-sensing Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Energy and Power Engineering Jiangsu University Zhenjiang Jiangsu People's Republic of China

Faculty of Science Jiangsu University Zhenjiang Jiangsu People's Republic of China

Department of Agricultural and Bioresources Engineering University of Nigeria Nsukka Nigeria

Funding

National Natural Science Foundation of China

References (20)

Show source-provided references
1. 10.1088/0960‐1317/15/2/R0110.1088/0960‐1317/15/2/R01 ↗
2. 10.1063/1.355299210.1063/1.3552992 ↗
3. Oosterbroek R.E. · 2003
4. 10.1126/science.106623810.1126/science.1066238 ↗
5. 10.1007/s10404‐005‐0041‐z10.1007/s10404‐005‐0041‐z ↗
6. 10.1002/352760195310.1002/3527601953 ↗
7. 10.1021/ac026173j10.1021/ac026173j ↗
8. Characteristics of valveless piezoelectric micropump based on logarithmic spiral composite tube
9. 10.1016/j.ces.2004.11.03310.1016/j.ces.2004.11.033 ↗
10. 10.1007/128_2011_15010.1007/128_2011_150 ↗
11. 10.1016/j.ces.2010.08.01610.1016/j.ces.2010.08.016 ↗
12. 10.1021/la200223g10.1021/la200223g ↗
13. 10.1021/ac015541110.1021/ac0155411 ↗
14. 10.1088/0960‐1317/14/10/01410.1088/0960‐1317/14/10/014 ↗
15. 10.1088/0960‐1317/17/5/02310.1088/0960‐1317/17/5/023 ↗
16. Mixing performance of a novel passive micromixer with logarithmic spiral channel
17. 10.1016/j.cej.2010.05.06810.1016/j.cej.2010.05.068 ↗
18. 10.1016/j.ijheatmasstransfer.2016.09.03410.1016/j.ijheatmasstransfer.2016.09.034 ↗
19. 10.1016/j.cej.2010.05.05610.1016/j.cej.2010.05.056 ↗
20. Tran‐Minh N. · 2014 · 91