Minimising Sample Preparation Damage for Beam Sensitive Polymer Matrix Composite Materials (Paint)
Source abstract
Abstract
Polymer matrix composites (MMC) is a type of material which has a large range of important applications. Paint is considered one of the most used MMC all over the world. Its pigment usually provides colour, rheological control, corrosion inhibition, and many more properties, of the paint. Precise characterization of the pigment in paint is therefore required by industry for improving the paint quality, and by academic research for developing better paint systems. Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) are commonly used imaging techniques for pigment characterization in paint system studies [1]. Ultramicrotomy has been used for slicing paint samples due to paint usually being soft and ductile. However, some of the pigments in paint could be pulled out or dislocated during the slicing process if the pigment and the matrix have large differences in hardness between them [2]. Lin et al [3] used focused ion beam (FIB) to study TiO2 pigment distribution. Depending on the pigment type and the resin, FIB might induce unwanted sample damage [4]. Here we report our journey on overcoming the challenges and finally getting a ‘correct’ result during sample preparation for SEM imaging. We compared ultramicrotome sample preparation, FIB sample preparation and cryo-plasma FIB (cryo-pFIB) sample preparation of an exemplar paint sample for SEM imaging. The ultramicrotome prepared sample resulted in pore formation. This problem might be due to the combined effect of mechanical force of the ultramicrotome pulling out the pigment particles, and the distilled water used during the cutting process dissolving the pigment. Note that there were no knife marks, meaning this technique can be useful to samples which are not sensitive to water/solutions. The FIB prepared samples had no pull out or dissolved pores, but ion beam damage was observed which might be caused by local melting which specifically affected beam-sensitive pigments. Cryo-pFIB prepared samples had the least damage to the pigment even though curtaining and rippling was observed. Figure 1 shows the different advantages and issues as discussed above. Nevertheless, some technical tricks, for example reducing milling current, a thick coating/top-layer and post milling FFT image processing techniques may be applied appropriately to reduce the cryo-pFIB curtaining. We noticed the room temperature pFIB had less curtaining/ripple than cryo-pFIB which might be due to the low temperature hardening the sample. We conclude the cryo-pFIB is the best technique of choice for studying pigment particle dissolution or distribution (Figure 2). Cryo-FIB might have less curtaining/ripple issues than cryo-pFIB. It is anticipated the best technique for TEM sample preparation of paint samples is the cryo-pFIB (or cryo-FIB as we only have cryo-pFIB). The cryo-pFIB technique could be used for many other types of MMC materials. Comparison of ultramicrotome, FIB and cryo-pFIB prepared sample: ultramicrotome induced pigment dissolution/mechanical pull-out, FIB ion beam induced local beam damage/local heating, cryo-pFIB has least damage/modification to the pigment microstructure but there are some curtaining/ripples. Lower magnification of Figure 1 where most precise pigment particle distributions could be obtained with the cryo-pFIB prepared samples.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Polymer Nanocomposite Synthesis and Irradiation · Ion-surface interactions and analysis · Electron and X-Ray Spectroscopy Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Materials, University of Manchester , Manchester , UK
References (3)
Show source-provided references
1. Inhibition mechanism of anticorrosion pigments leached from organic coatings: Comparison between salt spray and immersion testing10.1016/j.porgcoat.2022.107266 ↗
2. Multi-modal plasma focused ion beam serial section tomography of an organic paint coating10.1016/j.ultramic.2018.10.003 ↗
3. Minimizing damage during FIB sample preparation of soft materials10.1111/j.1365-2818.2011.03570.x ↗