journal article·2018-08Open access

Study of fire behaviour of facade mock‐ups equipped with aluminium composite material‐based claddings, using intermediate‐scale test method

Eric Guillaume, Talal Fateh, Renaud Schillinger, Roman Chiva, Sebastian Ukleja

Fire and Materials· Volume 42· Issue 5

Abstract

Summary The fire behaviour of a building façade is dependent on the overall system's performance, rather than the performance of the individual components. A façade system includes the cladding and the insulant's characteristics, but also the cavities, cavity barriers, mounting and fixings, substrate, and any singularities, such as window frames. This publication presents façade fire propagation test according to the ISO 13785‐1 standard, with additional heat release rate and gases analysis using FTIR. Tests have been performed on 9 different compositions of aluminium composite panels (ACM) with several insulants. For tested compositions, the cladding is the most important parameter driving global fire behaviour of façade mock‐ups. ACM‐PE‐based cladding systems gave very different results from the other solutions tested. This was especially visible in heat release rates, where fire intensity was very high, whatever the insulant used in the system. The contribution of the insulant was only remarkable in these tests during the decay phase. The cavity barrier was largely ineffectual in the 3 tests with ACM‐PE cladding, as the integrity of the cavity was not ensured.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on concrete materials · Hygrothermal properties of building materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Efectis France, route de l'Orme des Merisiers 91193 Saint Aubin Cedex France

Efectis UK‐Ireland Jordanstown Campus Block 27, Shore Road Newtownabbey BT 37 0QB UK

Ulster University, FIRESERT Jordanstown Campus Block 27, Shore Road Newtownabbey BT 37 0QB UK

References (33)

Show source-provided references
1. Facades market analysis by product (ventilated non‐ventilated) by end use (commercial residential industrial) by region (North America Europe Asia Pacific) and segment forecasts 2014–2025. Report ID: GVR‐1‐68038‐221‐1. Published Nov 2017.
2. Cladding market analysis by product (steel aluminum composite panels fiber cement terracotta ceramic) by application competitive landscape and segment forecasts 2014–2025. Report ID: GVR‐1‐68038‐477‐2. Published Jun 2017.
3. ValiulisJ.Building exterior wall assembly flammability: have we forgotten the past 40 years?In fire Engineering Magazine November2015.
4. WhiteN DelichatsiosM.Fire hazards of exterior wall assemblies containing combustible components. FPRF final report project FE2568 Quincy MA USA.2004.
5. WhiteN DelichatsiosM AhrensM A.Kimball.Fire hazard of exterior wall assemblies containing combustible components. Proceedings of 1stinternational seminar for fire safety of facades. Paris.2013:77–88.
6. Interim report into the Review of Building Regulations and Fire Safety. UK Department for Communities and Local Government issued 18 December2017https://www.gov.uk/government/news/interim‐report‐into‐the‐review‐of‐building‐regulations‐and‐fire‐safety
7. BS 8414–1:2015+A1:2017.Fire performance of external cladding systems. Test method for non‐loadbearing external cladding systems applied to the masonry face of a building
8. BR135.ColwellS BakerT.Fire performance of external thermal insulation for walls of multistorey buildings 3rdedition IHS/BRE
9. Collection: Grenfell Tower UK Department for Communities and Local Government Last Update22November2017https://www.gov.uk/government/collections/grenfell‐tower
10. BRE. Fire test report: DCLG BS 8414 Test.2017;1:7August.
11. BRE. Fire test report: DCLG BS 8414 Test.2017;2:3August.
12. BRE. Fire test report: DCLG BS 8414 Test.2017;3:8August.
13. BRE. Fire test report: DCLG BS 8414 Test.2017;4:11August.
14. BRE. Fire test report: DCLG BS 8414 Test.2017;5:14August.
15. BRE. Fire test report: DCLG BS 8414 Test.2017;6:25August.
16. BRE. Fire test report: DCLG BS 8414 Test.2017;7:21August.
17. AgarwalG.Research Technical Report: evaluation of the fire performance of aluminum composite material (ACM) assemblies using ANSI/FM 4880. FM Global Norwood MA02062 USA December2017.
18. NFPA 285.Standard fire test method for evaluation of fire propagation characteristics of exterior non‐load‐bearing wall assemblies containing combustible components.2012.
19. ISO 13785–1:2002.Reaction‐to‐fire tests for façades—Part 1: Intermediate‐scale test.
20. ISO 24473:2008.Fire tests—open calorimetry—measurement of the rate of production of heat and combustion products for fires of up to 40 MW.
21. ISO 16405:2015.Room corner and open calorimeter—guidance on sampling and measurement of effluent gas production using FTIR technique.
22. ISO 19702:2015.Guidance for sampling and analysis of toxic gases and vapours in fire effluents using Fourier Transform Infrared (FTIR) spectroscopy
23. ISO 9705‐1:2016.Reaction to fire tests—room corner test for wall and ceiling lining products—Part 1: Test method for a small room configuration.
24. EN 13238:2012.Reaction to fire tests for building products—conditioning procedures and general rules for selection of substrates.
25. ISO 14934‐1:2010.Fire tests—calibration and use of heat flux meters—part 1: general principles.
26. 10.1080/1478644020863562710.1080/14786440208635627 ↗
27. 10.1002/fam.81004020210.1002/fam.810040202 ↗
28. 10.1007/BF0103844910.1007/BF01038449 ↗
29. ISO 19701:2013.Methods for sampling and analysis of fire effluents.
30. ISO 19702:2015.Guidance for sampling and analysis of toxic gases and vapours in fire effluents using Fourier Transform Infrared (FTIR) spectroscopy.
31. GuillaumeE SaragozaL.Application of FTIR analyzers to fire gases—progress in apparatus and method validation for quantitative analysis. Fire and materials 2015 San Francisco USA 2–4 Feb 2015.
32. ISO 19703:2010.Generation and analysis of toxic gases in fire—calculation of species yields equivalence ratios and combustion efficiency in experimental fires.
33. ISO 19706:2011.Guidelines for assessing the fire threat to people.