Modelling thermal performance of gypsum plasterboard‐lined light timber frame walls using SAFIR and TASEF
Source abstract
Abstract
Abstract Gypsum plasterboard is commonly used as a lining material on lightweight timber or steel framing. Gypsum contains moisture, both free and chemically bound in its crystal structure. The dehydration of the gypsum and decomposition of calcium carbonate absorb heat giving gypsum plasterboard fire resistant qualities. This paper discusses the suitability of the finite element heat transfer program SAFIR for modelling plasterboard‐lined light timber frame assemblies and its limitations. The default material properties in SAFIR for gypsum plasterboard do not give good results and ‘smoothing’ of enthalpy curves has insignificant effects on the results but substantially reduces processing time. Modelling with SAFIR gives similar results to prior modelling using the program TASEF with slight differences. Both programs give better overall results for slower developing fires and furnace tests than more rapidly growing fires. Reasonable, slightly conservative results for thermal analysis of heat transfer through the walls and into timber studs can be achieved using the parameters suggested in this paper. More sophisticated and detailed models incorporating mass transfer, effect of fasteners, gaps between lining sheets and ablation are required to achieve better comparisons. Copyright © 2010 John Wiley & Sons, Ltd.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Wood Treatment and Properties · Fire effects on concrete materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Sterner E · 1990
2. Hibbitt Karlsson and Sorensen Inc.ABAQUS User Manuals version 5.4. Pawtucket Rhode Island 1994.
3. ThomasGC.Fire resistance of light timber framed walls and floors. Ph.D. Dissertation University of Canterbury Christchurch 1997.
4. Thomas GC · 1997
5. 10.1002/fam.78610.1002/fam.786 ↗
6. SAFIR. A thermal/structural program modelling structures under fire10.62913/engj.v42i3.856 ↗
7. Model for predicting heat transfer through gypsum‐board/wood–stud walls exposed to fire10.1002/fam.810180505 ↗
8. Andersson L · 1987
9. 10.1007/BF0104021710.1007/BF01040217 ↗
10. Gypsum board in fire—modelling and experimental validation10.1177/0734904107072883 ↗
11. ISO‐834.Fire Resistance Tests—Elements of Construction.International Standards Organisation ISO‐834 1975.
12. KönigJ NorenJ.Fire tests on timber frame members in pure bending. Proceedings of International Conference on Timber Engineering London 1991;4.75–4.82.
13. Franssen JM · 2002
14. ClancyP.Time and probability of failure of timber framed walls in fire. Ph.D. Dissertation Faculty of Engineering and Science Victoria University of Technology Melbourne 1999.
15. Winstone Wallboards Limited · 1992
16. BabrauskasV.COMPF2 a program for calculating post‐flashover fire temperatures. NBS Technical Note 991 U.S. Department of Commerce/National Bureau of Standards Gaithersburg 1979.10.6028/NBS.TN.991 ↗