Impact of partial encapsulation on the fire dynamics of an open‐plan compartment with exposed timber ceiling and columns:CodeRed #04

Panagiotis Kotsovinos, Eirik G. Christensen, Adam Glew, Eoin O'Loughlin, Harry Mitchell, Rikesh Amin, Fabienne Robert, Mohammad Heidari, David Barber, Guillermo Rein, Judith Schulz

Fire and Materials· Volume 47· Issue 4
Publisher page

Abstract

Abstract The use of mass timber in construction is becoming a compelling option when faced with the high carbon footprint of traditional concrete and steel production. However, fire safety standards are yet to evolve to support these designs. Encapsulation is commonly used to protect all, or some, of the timber surfaces and reduce the risks introduced. This paper presents the results fromCodeRed #04, the final experiment of theCodeRedexperimental campaign. This experiment was carried out inside a purpose‐built facility to capture fire dynamics in large compartments with exposed timber.CodeRed #04had identical characteristics toCodeRed #01with the exception that ~50% of the cross‐laminated timber (CLT) ceiling was encapsulated. The experiments were intentionally similar to the traveling fire experiments,x‐ONEandx‐TWO, which had a non‐combustible ceiling to enable a direct comparison. The overall fire dynamics experienced inCodeRed #04, intersect the characteristics observed inCodeRed #01andx‐ONEandx‐TWO.1. InCodeRed #04, there was a delay in the ignition of the CLT ceiling as the CLT directly above the crib was encapsulated. Once the CLT ceiling ignited, the fire spread rapidly throughout the compartment. The peak heat release rate (HRR) was estimated to be approximately 100 MW, a 17% decrease fromCodeRed #01. Following CLT ignition the resulting fire duration, maximum temperatures, and heat fluxes were broadly similar toCodeRed #01. Flame heights of approximately 1.5 m were observed from the windows while flame heights of 2.5–3 m were observed inCodeRed #01. Therefore, flame heights were found to be comparable tox‐TWO.1, though over a greater number of windows, reflecting the greater extent of simultaneous burning within the compartment. The average charring depth of the exposed CLT panels was ~25 mm, which is similar to that measured inCodeRed #01‐suggesting that the fire severity near the ceiling was not strongly impacted by the 50% encapsulation of timber. No charring was observed where the ceiling was encapsulated and loaded service fixings installed through the encapsulation were found to be less likely to fail than when attached directly to the exposed timber. Smoldering was observed after the cessation of flaming and, in a few locations, was observed to progress through the thickness of the CLT panel and continue behind the encapsulation. This illustrates that, while encapsulation can succcessfully prevent flaming, it cannot be completely relied on to avoid smouldering. The findings fromCodeRed #04contribute to the development of evidence‐based fire safety design methodologies for exposed mass timber buildings.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Fire Engineering Arup London UK

Department of Mechanical Engineering Imperial College London London UK

Fire Testing Centre CERIB Épernon France

Fire Engineering Arup Melbourne Australia

Funding

ARUP Laboratories

References (22)

Show source-provided references
1. 10.56330/XJPS166110.56330/XJPS1661 ↗
2. Fire safety design in modern timber buildings10.56330/WTER3078 ↗
3. 10.1016/j.jobe.2020.10118110.1016/j.jobe.2020.101181 ↗
4. 10.1007/s10694-020-01047-010.1007/s10694-020-01047-0 ↗
5. Fire dynamics inside a large and open‐plan compartment with exposed timber ceiling and columns: CodeRed #01
6. 10.1007/s10694-021-01162-610.1007/s10694-021-01162-6 ↗
7. Impact of ventilation on the fire dynamics of an open‐plan compartment with exposed timber ceiling and columns: CodeRed #02
8. The effectiveness of a water mist system in an open‐plan compartment with an exposed timber ceiling: CodeRed # 03
9. Heidari M · 2021
10. 10.1016/j.firesaf.2017.03.07410.1016/j.firesaf.2017.03.074 ↗
11. Brandon D. Sjöström J. Hallberg E. Temple A. andKahl F. “Fire Safe Implementation of Visible Mass Timber in Tall Buildings – Compartment Fire Testing ”2020.
12. Fire dynamics inside an open‐plan compartment with an exposed CLT ceiling and glulam columns: CodeRed #01
13. BSi “UK National Annex to Eurocode 2: Design of concrete structures; Part 1–2: Structural fire design ”2004.
14. 10.1016/j.proci.2018.06.08010.1016/j.proci.2018.06.080 ↗
15. 10.1016/0010-2180(76)90059-610.1016/0010-2180(76)90059-6 ↗
16. 10.1016/j.firesaf.2020.10309810.1016/j.firesaf.2020.103098 ↗
17. Special Metals Corporation “Inconel alloy 600 SMC‐027 ”2008. [Online]. Available:https://www.specialmetals.com/documents/technical-bulletins/inconel/inconel-alloy-600.pdf.
18. 10.1002/978111997546510.1002/9781119975465 ↗
19. 10.1016/j.firesaf.2020.10307710.1016/j.firesaf.2020.103077 ↗
20. Fire and steel construction: fire safety of bare external structural steel
21. 10.1021/ac60214a04710.1021/ac60214a047 ↗
22. 10.1016/j.firesaf.2019.10282710.1016/j.firesaf.2019.102827 ↗