Fire performance of bolted connections in laminated veneer lumber
Source abstract
Abstract
Abstract This paper describes an investigation into the fire performance of bolted tensile connections in laminated veneer lumber (LVL) made from radiata pine. The capacity of the bolted connections depends on the embedment strength of the wood and on the yield moment of the bolts. The purpose of the research was to develop a prediction method for the time to failure of the connections when exposed to fire. An experimental investigation was carried out on the axial tensile strength of three types of bolted connections that utilized either wood or steel splice plates. Some specimens were tested at ambient temperatures while similar specimens were tested in fire conditions with a constant applied load. In addition, single‐bolted connections were tested under constant elevated temperature conditions to determine the embedment strength of the LVL. Connections with no steel plates, or with steel plates slotted between the timber members, performed better than those with exposed steel. A simplified design approach is proposed, using an extension of the Johansen formulae, such that the embedment strength of the LVL depends on the temperature in the bolt. Copyright © 2009 John Wiley & Sons, Ltd.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Tree Root and Stability Studies · Structural Analysis of Composite Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. 10.1002/fam.75910.1002/fam.759 ↗
2. ReszkaP ToreroJL.In depth temperature measurements of timber in fires. The 4th International Workshop on Structures in Fire Aveiro Portugal 2006.
3. JongF ClancyP.Compression properties of wood as functions of moisture stress and temperature. Proceedings of the 2nd International Workshop on Structures in Fire Christchurch New Zealand 2002;223–242.
4. JanssensM.Modeling of the thermal degradation of structural wood members exposed to fire. Proceedings of the 2nd International Workshop on Structures in Fire Christchurch New Zealand 2002;211–222.
5. FrangiA MischlerA.Fire tests on timber connections with dowel type fasteners. Working Commission W18—Timber Structures Meeting 37 International Council for Research and Innovation in Building and Construction Edinburgh U.K. August 2004.
6. ErchingerC FrangiA MischlerA.Fire behaviour of multiple shear steel‐to‐timber connections with dowels. Working Commission W18—Timber Structure Meeting 38 International Council for Research and Innovation in Building and Construction Karlsruhe Germany 2005.
7. ErchingerC FrangiA MischlerA.Thermal investigations on multiple shear steel‐to‐timber connections. Proceedings of the World Conference on Timber Engineering Portland OR U.S.A. 2006.
8. LaplancheK DhimaD RacherP.Thermo‐mechanical modelling of the timber connection under fire using 3D finite element model. Proceedings of the World Conference on Timber Engineering Portland OR U.S.A. 2006.
9. SchablS TurkG.Coupled heat and moisture transfer in timber beams exposed to fire. Proceedings of the World Conference on Timber Engineering Portland OR U.S.A. 2006.
10. 10.1007/s00107-004-0568-910.1007/s00107-004-0568-9 ↗
11. ChapuisS MoraesPD RogaumeY ToreroJL.Evaluation of in‐depth temperature distributions and embedding resistance of timber in a fire Private communication 2006.
12. ChuoTCB. Fire performance of connections in LVL structures. Fire Engineering Research Report 07/4 Department of Civil Engineering University of Canterbury New Zealand.http://www.civil.canterbury.ac.nz/fire/fe_resrch_reps.shtml 2007.
13. LauPH. Fire resistance of connections in laminated veneer lumber. Fire Engineering Research Report 06/3 Department of Civil Engineering University of Canterbury New Zealand.http://www.civil.canterbury.ac.nz/fire/fe_resrch_reps.shtml 2006.
14. 2002
15. 1993
16. 2000
17. HarrisS.Fire resistance of epoxy‐grouted steel rod connections in laminated veneer lumber (LVL). Fire Engineering Research Report 04/7 Department of Civil Engineering University of Canterbury New Zealand 2004.
18. Buchanan AH · 2001
19. Lane W · 2004
20. NymanJF.Equivalent fire resistance ratings of construction elements exposed to realistic fires. Fire Engineering Research Report 02/13 University of Canterbury New Zealand 2001.
21. 10.1002/fam.87310.1002/fam.873 ↗
22. 1999