Dynamic modeling of syringe-pump-actuated microliquid-dispensing system by a bond-graph approach
Source abstract
Abstract
Microliquid-dispensing technology is widely used in the life sciences and other fields. In this paper, a syringe-pump-actuated microliquid-dispensing system is designed, and its bond-graph model is constructed. Combining a syringe pump and pipeline, the system controls the piston movement inside the syringe pump to dispense microliquid. The bond-graph model is derived from integrating the electromechanical model with the fluid model. The lumped parameter method is utilized to divide the fluid model into several blocks for higher accuracy. Model correctness is verified by simulations and experiments, and further simulation studies on the pipeline pressure and flow rate based on the bond-graph model are carried out. Results are used to guide the design and control work on the proposed system.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrowetting and Microfluidic Technologies · Microfluidic and Capillary Electrophoresis Applications · Fluid Dynamics and Thin Films
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. Ando T, Hirano M, Ishige Y, Adachi S (2018) Precise dispensing technology using electroformed tubes for micro-volume blood diagnosis. IEEE J Transla Eng Health Med. https://doi.org/10.1109/JTEHM.2018.285266410.1109/JTEHM.2018.2852664 ↗
2. Bammesberger SB, Malki I, Ernst A, Zengerle R, Koltay P (2014) A calibration-free, noncontact, disposable liquid dispensing cartridge featuring an online process control. J Lab Autom 19(4):394–40210.1177/2211068213499757 ↗
3. Borutzky W, Dauphin-Tanguy G, Thoma JU (1995) Advanced in bond graph modelling: theory, software, applications. Math Comput Simul 39(5–6):465–47510.1016/0378-4754(95)00106-6 ↗
4. Chen XB, Kai J (2004) Modeling of positive-displacement fluid dispensing processes. IEEE Trans Electron Packag Manuf 27(3):157–16310.1109/TEPM.2004.843083 ↗
5. Chen XB, Pharoah JG, Surgenor BW (2003). Theoretical investigation into the performance of the positive-displacement dispensing process. In: ASME 2003 international mechanical engineering congress and exposition10.1115/IMECE2003-42739 ↗
6. Doebelin EO (1972) System dynamics modeling and response. Bell and Howell, Columbus
7. Gavira JA (2016) Current trends in protein crystallization. Arch Biochem Biophys 602(2016):3–1110.1016/j.abb.2015.12.010 ↗
8. He NY, Liu T, Liu B (2016) Technologies and applications in micro-volume liquid handling. J Nanosci Nanotechnol 16(1):58–6610.1166/jnn.2016.11681 ↗
9. Heather JM, Chain B (2016) The sequence of sequencers: the history of sequencing DNA. Genomics 107(1):1–810.1016/j.ygeno.2015.11.003 ↗
10. Karimaghaee P, Hosseinzadeh A, Amidi A, Roshandel E (2017) Adaptive control application on syringe pump pressure control systems in oil and gas industries. In: Proceedings of 5th international conference on control, instrumentation, and automation, pp 259–26410.1109/ICCIAutom.2017.8258689 ↗
11. Liu S, Xu D, Li YF, Shen F, Zhang DP (2017) Nanoliter fluid dispensing based on microscopic vision and laser range sensor. IEEE Trans Industr Electron 64(2):1292–130210.1109/TIE.2016.2611459 ↗
12. Lu SZ (2015) Research of needle-type piezostack driven micro dispensing technology for high viscosity liquids. Dissertation, Harbin Institute of Technology
13. Lu SZ, Zhou FQ, Liu W, Ren CL, Yan FB (2017) Research of biological reagent droplet formation in valve-control dispensing method. In: Proceedings of IEEE international conference on electronics information and emergency communication, pp 473–476
14. Mahmoud I, Rehaoulia H (2016) Design, nonlinear modelling and performances of a biomedical system. Int J Appl Electromagn Mech 50(1):127–14310.3233/JAE-150085 ↗
15. Saitoh M (2011) Lumped parameter models representing impedance functions at the interface of a rod on a viscoelastic medium. J Sound Vib 330(9):2062–207210.1016/j.jsv.2010.10.042 ↗
16. Sun S, Kennedy RT (2014) Droplet electrospray ionization mass spectrometry for high throughput screening for enzyme inhibitors. Anal Chem 86(18):9309–931410.1021/ac502542z ↗
17. Wang LY, Du XH, Li YP et al (2014) Simulation and experiment study on adhesive ejection behavior in jetting dispenser. J Adhes Sci Technol 28(1):53–6410.1080/01694243.2013.827091 ↗
18. Zeng DW, Wang Z, Wang MJ, Eichstaedt O, Yuan H (2017) Automatic bio-sampling system based on micro injection pump and pneuamtic micro valves. In: Proceedings of 2017 Chinese automation congress, pp 4140–414610.1109/CAC.2017.8243506 ↗
19. Zhou C, Deng GL, Li JH, Duan JA (2018) Flow channel influence of a collision-based piezoelectric jetting dispenser on jet performance. Sensors. https://doi.org/10.3390/s1804127010.3390/s18041270 ↗
20. Zhu LQ, Li H, Na YX et al (2011) Novel method for ELISA traces pipetting system by air displacement pipetting. Appl Mech Mater 103:252–25610.4028/www.scientific.net/AMM.103.252 ↗