journal article·2025-11Open access

Influence of Sidewall Effects on Ejected Flame During Facade Calibration Tests: Experimental Analysis and Findings

Xukun Sun, Hideki Yoshioka, Takafumi Noguchi, Yuhei Nishio, Yoshifumi Ohmiya, Tetsuya Hayakawa, Biao Zhou

Fire and Materials· Volume 49· Issue 7

Abstract

ABSTRACT The inclusion of sidewalls is a typical architectural feature in building façades, which has raised significant concerns about their potential to accelerate flame spread, particularly with the increasing prevalence of high‐rise buildings. This paper presents an experimental investigation and analysis of façade flame with a single sidewall. Experiments were conducted by employing a large‐scale façade calibration test, following the standard of JIS A 1310 with additional sidewall configurations. The distance between a sidewall and a façade opening was parametrically changed. A propane burner located at the rear center of the combustion chamber provides a quasi‐steady heat release rate (HRR) ranging from 600 to 900 kW. It is found that the flame height is more affected by sidewall distances when the HRR is sufficiently larger than the outflow HRR. Combined with flame and façade temperatures, a sidewall distance of 0.2 m is considered crucial for the performance of fire loads in the case of sidewall façades with square openings. The temperature of the flame trajectory is characterized by the neutral plane (NP)‐adapted Yokoi model, with improved convergence under varied HRRs and sidewall distances.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Combustion and Detonation Processes · Combustion and flame dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Architecture, Faculty of Engineering The University of Tokyo Tokyo Japan

Department of Fire Engineering Building Research Institute Tsukuba Japan

Department of Architecture, Faculty of Science and Technology Tokyo University of Science Chiba Japan

Tokyo System Vac. (TSV) Saitama Japan

School of Emergency Management and Safety Engineering China University of Mining and Technology (Beijing) Beijing China

References (21)

Show source-provided references
1. 10.1016/j.jhazmat.2018.12.07710.1016/j.jhazmat.2018.12.077 ↗
2. Study on the Prevention of Fire Spread Caused by Hot Upward Current
3. 10.1016/j.proci.2006.08.03310.1016/j.proci.2006.08.033 ↗
4. 10.3801/IAFSS.FSS.11-310.3801/IAFSS.FSS.11-3 ↗
5. 10.1016/j.firesaf.2012.01.00110.1016/j.firesaf.2012.01.001 ↗
6. 10.1016/j.jobe.2022.10432210.1016/j.jobe.2022.104322 ↗
7. 10.1002/fam.280710.1002/fam.2807 ↗
8. 10.1016/j.firesaf.2019.10294410.1016/j.firesaf.2019.102944 ↗
9. 10.1007/s10973-021-10926-910.1007/s10973-021-10926-9 ↗
10. 10.1002/fam.319210.1002/fam.3192 ↗
11. JIS A 1310 “Test Method for Fire Propagation Over Building Facades Published by: Japanese Standards Association (JSA) Japan 2019 ”(2019).
12. JIS C 1602 “Thermocouple Published by: Japanese Standards Association (JSA) Japan ” (2015).
13. 10.1007/BF0259161210.1007/BF02591612 ↗
14. Numerical Investigation of the Thermal Exposure of Façade During BS 8414 Test Series: Influence of Wind and Fire Source
15. Predictive Method for Properties of Flame Ejected From an Opening Incorporating Excess Fuel
16. 10.1016/j.firesaf.2008.06.00710.1016/j.firesaf.2008.06.007 ↗
17. Thermal Behavior of Window Plume Generated by Fully Developed Compartment Fires in Single‐Skin and Double‐Skin Façade Scenarios
18. 10.1201/978142005021910.1201/9781420050219 ↗
19. 10.1016/j.firesaf.2017.03.07510.1016/j.firesaf.2017.03.075 ↗
20. 10.3801/IAFSS.FSS.11-43210.3801/IAFSS.FSS.11-432 ↗
21. 10.1007/s10694-019-00845-510.1007/s10694-019-00845-5 ↗