Heat release rates of modern residential furnishings during combustion in a room calorimeter
Source abstract
Abstract
Summary Results are presented from a number of fire experiments that were conducted in a room environment to study the fire characteristics of typical residential furnishings and assist in the design of a subsequent phase of a project involving fully furnished room fire experiments. The experiments were conducted in a 16‐m2 test room (with dimensions 3.8 m wide × 4.2 m long × 2.4 m high), which had a 1.5 × 1.5‐m window opening. The furnishings tested included mattresses, bed clothes, bed assemblies, upholstered seating furniture, clothing arrangements, books, plastic audio/video media and storage cases, toys, shoes, and a computer workstation setup. The smoke (gaseous products of combustion) from the room was collected using a hood system in order to measure the heat release rate (HRR) and optical density of the smoke. The test room was instrumented with load cells, heat flux gauges, thermocouples and velocity probes in order to take the following measurements: mass loss, total heat flux on gauge‐installed flush with the internal surfaces (floor, walls, and ceiling), temperatures at numerous locations, and gas velocities in the window opening. Twin‐size mattresses produced peak HRRs of approximately 3800 kW, and the maximum room temperature was approximately 980°C. The HRRs of bed assemblies of various sizes and configurations ranged from 1800 kW for a twin‐size bed to 6250 kW for a bunk bed. The maximum temperature and heat flux recorded in the experiments were 1071°C and 221 kW/m2, respectively. Upholstered chairs and sofas had HRRs ranging from 630 kW for an ottoman to 3360 kW for a two‐seat sofa. In tests with clothing, toys, shoes, books, a computer workstation, and CD/DVD media, the peak HRRs ranged from 440 kW for a bookcase to 2045 kW for toys. Furnishings containing a large proportion of rigid thermoplastic plastics, such as shoes and media cases, produced very dense smoke even at low HRRs. The effect of parameters such as bed clothes, mattress type, foundation type, bed assembly and chair size, material composition, and fuel package arrangement was evident in the results. Because the room dimensions and wall lining materials remained constant, temperatures were linearly proportional to the peak HRR (and exposure time) until the ventilation limit (approximately 4100 kW) was reached. Copyright © 2014 John Wiley & Sons, Ltd.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Combustion and Detonation Processes · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
National Research Council Canada Construction, Fire Safety Ottawa Ontario K1A 0R6 Canada
Funding
National Research Council Canada
References (28)
Show source-provided references
1. BwalyaA LougheedG KashefA.Characterization of Fires in Multi‐Suite Residential Dwellings: Phase 1 ‐ Room Fire Experiments with Individual Furnishings. Institute for Research in Construction National Research Council Canada Research Report IRC‐RR‐302 Ottawa Canada 2010.
2. BabrauskasV LawsonRJ WaltonWD TwilleyWH.Upholstered Furniture Heat Release Rates Measured With a Furniture Calorimeter. NBSIR 82–2604 US Dept of Commerce National Bureau of Standards Gaithersburg U.S.A. 1982.10.6028/NBS.IR.82-2604 ↗
3. KrasnyJF ParkerWJ.Impact of the Room Enclosure on the Peak Heat Release Rates of Upholstered Furniture. 4th International Fire and Materials Conference 1995;181–190.
4. 10.1177/07349041920100050210.1177/073490419201000502 ↗
5. OhlemillerTJ ShieldsJR McLaneRA GannRG.Flammability Assessment Methodology for Mattresses. Building and Fire Research Laboratory National Institute of Standards and Technology NISTIR 6497 Gaithersburg U.S.A. 2000.
6. SundströmB(ed.).Fire Safety of Upholstered Furniture ‐ The Final Report of the CBUF Research Programme. Report EUR 16477 EN Directorate‐General Science Research and Development (Measurements and Testing) European Commission Interscience Communications Ltd London U.K. 1995.
7. HirschlerMM.Full‐Scale Fire Testing of Consumer Products. 10thEuropean Meeting on Fire Retardancy and Protection of Materials (10th European Conference on Fire Retardant Polymers) (September) Berlin Germany 2005.
8. OhlemillerTJ GannRG.Effect of Bed Clothes Modifications on Fire Performance of Bed Assemblies. Building and Fire Research Laboratory National Institute of Standards and Technology NIST Technical Note 1449 Gaithersburg USA 2003.10.6028/NIST.TN.1449 ↗
9. Survey Results of Combustible Contents and Floor Areas in Canadian Multi‐Family Dwellings
10. United States Consumer Product Safety Commission.16 CFR Part 1633: Standard for the Flammability (Open Flame) of Mattress Sets. United States Consumer Product Safety Commission Laboratory Test Manual 2008.
11. BwalyaA LougheedG KashefA SaberH.Survey Results of Combustible Contents and Floor Areas in Canadian Multi‐Family Dwellings.Institute for Research in Construction National Research Council Canada Research Report IRC‐RR‐253 November Ottawa Canada 2008.
12. The Upholstered Furniture Action Council www.ufac.org September 2008.
13. BwalyaA GibbsE LougheedG KashefA SaberH.Design of a Single‐Room Heat Release Rate Calorimeter for the Characterization of Fires in Multi‐Suite Residential Dwellings Project.Institute for Research in Construction National Research Council Canada Research Report IRC‐RR‐267 Ottawa Canada 2008.
14. SaberH KashefA BwalyaA LougheedG SultanM.A Numerical Study on the Effect of Ventilation on Fire Development in a Medium‐Sized Residential Room.Institute for Research in Construction National Research Council Canada Research Report IRC‐RR‐241 Ottawa Canada 2008.
15. Karlsson B · 2000
16. Deal S · 1995
17. 10.1007/BF0235180110.1007/BF02351801 ↗
18. 10.1016/0010-2180(76)90062-610.1016/0010-2180(76)90062-6 ↗
19. 10.1007/BF0103844910.1007/BF01038449 ↗
20. CramptonG LougheedG.COMPARISON OF SMOKE MEASUREMENTS WITH STANDARD AND NONSTANDARD SYSTEMS. National Research Council Canada Institute for Research in Construction Research Report #183 Ottawa Canada 2004.
21. ASTM Standard E1523‐02a.Standard Test Method for Fire Testing of Upholstered Furniture. ASTM International West Conshohocken PA 2002.
22. 10.1002/(SICI)1099-1018(199603)20:2<61::AID-FAM558>3.0.CO;2-610.1002/(SICI)1099-1018(199603)20:2<61::AID-FAM558>3.0.CO;2-6 ↗
23. BryantRA OhlemillerTJ JohnssonEL HaminsA GroveBS GuthrieWF MaranghidesA MulhollandGW.The NIST 3 Megawatt Quantitative Heat Release Rate Facility. NIST Special Publication 1007 National Institute of Standards and Technology U.S. Department of Commerce USA 2003.10.6028/NIST.SP.1007 ↗
24. 10.1002/fam.89510.1002/fam.895 ↗
25. DamantG NurbakhshS MikamiJ.Full‐Scale Heat Release Rate Tests on Bedding Systems. Product Safety Corporation Seventeenth International Conference on Fire Safety ‐ Proceedings of the international conference on fire safety 1992;17:38.
26. Ohlemiller TJ · 200310.6028/NIST.IR.7006 ↗
27. Babrauskas V10.6028/NBS.MONO.173 ↗
28. ApteV EdwardsA FleischmannC BrianJ WadeC YoungE YoungD.Design Fires for Apartment Buildings ‐ Literature Review. BRANZ Study Report 136 BRANZ Ltd Porirua City New Zealand 2005.