Abstract It has become apparent from the series of fire tests carried out at Cardington, UK that the response of steel‐concrete composite structures in fire conditions is largely governed by the behaviour of the reinforced concrete floor slabs. This paper obtains a detailed understanding of the strength of heated concrete floor slabs when subject to the combined bending and membrane forces that typically result from restrained thermal expansion. To analyse such slabs the computer program FEAST is used. Initially the behaviour of the floor slab in the Cardington frame under pure bending and pure membrane forces is described and explained. The paper then explores the effect that interaction between bending and membrane behaviour has on the strength of the slab when it is uniformly heated, heated with a linear thermal gradient and heated with the non‐linear thermal gradient observed during the Cardington tests. Finally, the effects of varying the area and location of the reinforcement in the slab are analysed. Copyright © 2004 John Wiley & Sons, Ltd.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Response to Dynamic Loads · Fire dynamics and safety research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. BraveryPNR.Cardington Large Building Test Facility. Technical report. Building Research Establishment 1993.
2. RotterJM SanadAM UsmaniAS GillieM.Structural performance of redundant structures under local fires. In Proceeding of Interflam '99 Interscience Communications vol. 2 Scotland 1999.
3. SanadAM RotterJM UsmaniAS O'ConnorMA.Finite element modelling of fire tests on the Cardington composite building. In Proceedings Interflam '99 Interscience Communications vol. 2 Scotland 1999.
4. GillieM.Pit Project Research Report MD3: BS/TEST1 Model Using FEAST with Shell Elements. Technical report. University of Edinburgh 2000. Available athttp://www.civ.ed.ac.uk/research/fire/technicalreports.html.
5. GillieM.Pit Project Research Report AM3: Analysis of Results from BS/TEST1 Models Part C FEAST Shell Models. Technical report. University of Edinburgh 2000. Available athttp://www.civ.ed.ac.uk/research/fire/technicalreports.html.
6. O'ConnorM.Pit Project Research Report MD4: BS/TEST1 ABAQUS Model Using Shell Elements for the Beam and Beam General Section for the Slab. Technical report. British Steel 2000. Available athttp://www.civ.ed.ac.uk/research/fire/technicalreports.html.
7. 10.1016/S0379-7112(01)00038-810.1016/S0379-7112(01)00038-8 ↗
8. 10.1016/S0143-974X(01)00004-910.1016/S0143-974X(01)00004-9 ↗
9. GillieM.The Behaviour of Steel‐framed Composite Structures in Fire Conditions. PhD thesis University of Edinburgh 2000.
10. 10.1016/S0143-974X(01)00066-910.1016/S0143-974X(01)00066-9 ↗
11. Computer simulation of a full‐scale structural fire test
12. The behaviour of full‐scale steel‐framed buildings subject to compartment fires
13. The structural behaviour of steel frames with composite floor slabs subject to fire: Part 1: theory
14. The structural behaviour of steel frames with composite floor slabs subject to fire: Part 2: design
15. Non‐linear analysis of reinforced concrete slabs subject to fire
16. 10.1680/istbu.1999.3156710.1680/istbu.1999.31567 ↗
17. HuangZ BurgessIW PlankRJ.Non‐linear modelling of three full‐scale structural fire‐tests. In Structures in Fire‐Proceedings of First International Workshop Copenhagen Denmark Franssen J‐M (ed).2000;53–70.
18. 10.1016/S0379-7112(00)00044-810.1016/S0379-7112(00)00044-8 ↗
19. Owens GW · 1995
20. SanadAM.PIT Project Research Report AM1: Analysis of Results from BS/TEST1 Models Part A Grillage Models. Technical report. University of Edinburgh 2000. Available athttp://www.civ.ed.ac.uk/research/fire/technical reports.html
21. SanadAM.PIT Project Research Report AM6: Analysis of Results from BS/TEST3 Models Part A Grillage Models. Technical report. University of Edinburgh 2000. Available athttp://www.civ.ed.ac.uk/research/fire/technical reports.html
22. 10.1016/S0379-7112(01)00037-610.1016/S0379-7112(01)00037-6 ↗
23. KirbyBR.The Behaviour of a Multi‐Storey Steel‐framed Building Subjected to Fire Attacks Experimental Data. Technical report. British Steel Rotherham UK 1998.
24. Harmathy TZ · 1993
25. The effect of temperature on the compressive strength of concrete
26. 10.1016/0379-7112(88)90033-110.1016/0379-7112(88)90033-1 ↗
27. 1992
28. 1994
29. Gillie M · 2000
30. 10.1016/S0379-7112(01)00041-810.1016/S0379-7112(01)00041-8 ↗
31. 10.1016/S0141-0296(99)00110-810.1016/S0141-0296(99)00110-8 ↗