journal article·2006-10Open access

Experimental behaviour of a steel structure under natural fire

F. Wald, L. Simões da Silva, D.B. Moore, T. Lennon, M. Chladná, A. Santiago, M. Beneš, L. Borges

Fire Safety Journal· Volume 41· Issue 7

Abstract

Abstract Current design codes for fire resistance of structures are based on isolated member tests subjected to standard fire conditions. Such tests do not reflect the behaviour of a complete building under either normal temperature or fire conditions. Many aspects of behaviour occur due to the interaction between members and cannot be predicted or observed in tests of isolated elements. Performance of real structures subject to real fires is often much better than that predicted from standard tests due to structural continuity and the provision of alternative load paths. This paper reports on the results of a collaborative research project (Tensile membrane action and robustness of structural steel joints under natural fire, European Community FP5 project HPRI—CV 5535) involving the following institutions: Czech Technical University (Czech Republic), University of Coimbra (Portugal), Slovak Technical University (Slovak Republic) and Building Research Establishment (United Kingdom). It consists of an experimental programme to investigate the global structural behaviour of a compartment on the 8-storey steel–concrete composite frame building at the Cardington laboratory during a BRE large-scale fire test, aimed at the examination of the temperature development within the various structural elements, the corresponding (dynamic) distribution of internal forces and the behaviour of the composite slab, beams, columns and connections.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Wang · 2002
2. Petersson O, Magnusson SE, Thor J. Fire engineering design of steel structures, Publication No. 50, Swedish Institute of Steel Construction, Stockholm, 1976.
3. Witteveen J, Twilt L, Bijlaard FS. The stability of braced and unbraced frames at elevated temperatures. International symposium of stability of steel structures, Liège, 1977.
4. Kruppa J. Some results on the fire behaviour of external steel columns, Fire Saf J. 1981/2; 4:p. 247–57.10.1016/0379-7112(81)90028-X ↗
5. Genes DC. Predicted fire endurance of steel structures. American Society of Civil Engineering Conference, Las Vegas 1982. New York, ASCE, 1982.
6. The temperature attained by unprotected structural steelwork in experimental natural fires10.1016/0379-7112(87)90029-4 ↗
7. Structural steel and plane frame assemblies under fire action10.1016/0379-7112(86)90014-7 ↗
8. Anon T. Fire behaviour of steel and composite construction. Verlag, TUV, Rheinland, 1986.
9. The inherent fire resistance of a loaded steel framework
10. Thomas IR, et al. The effect of fire in the building at 140 William Street Office Building. BHP Research-Melbourne Laboratories report, 1992.
11. Bravery PNR. Cardington Large Building Test Facility, Construction details for the first building. Building Research Establishment, Internal paper, Watford 1993. p. 158.
12. Moore DB. Steel fire tests on a building framed. Building Research Establishment, Paper no. PD220/95, Watford 1995. p. 13.
13. Lennon T. Cardington fire tests: survey of damage to the eight storey building. Building Research Establishment, Paper no. 127/97, Watford 1997. p. 56.
14. Fire engineering design of steel structures10.1002/pse.2260010104 ↗
15. The behaviour of full-scale steel-framed building subject to compartment fires
16. Wald F, Santiago A, Chladná M, Lennon T, Burgess I, Beneš M. Tensile membrane action and robustness of structural steel joints under natural fire. Internal report, Part 1—Project of measurements; Part 2—Prediction; Part 3 – measured data; Part 4 – Behaviour, BRE, Watford, 2002–2003.
17. Numerical study to structural integrity of multi-story buildings under fire
18. ECSC 2002: Design recommendations for composite steel framed buildings in fire. Proj. 7210 PA, PB, PC, PD112, December 2002. p. 108.
19. CEN, Eurocode 1, Draft prEN—1991-1-2: 200x, Part 1.2: General actions – actions on structures exposed to fire, Eurocode 1: actions on structures, Final Draft, 2002, CEN, European Committee for Standardization, Brussels, 2002.
20. CEN, Eurocode 3, prEN—1993-1-2: 2003, Part 1.2: Structural Fire Design, Eurocode 3: Design of steel structures, Stage 49 draft, April 2003, CEN, European Committee for Standardization, Brussels, 2003.
21. Possible ‘panel-instability’ in composite deck floor systems under fire10.1016/S0143-974X(03)00083-X ↗
22. Effect of cooling on the behaviour of a steel beam under fire loading including the end joint response
23. Sokol Z, Wald F, Pultar M, Beneš M. Numerical simulation of Cardington fire test on structural integrity. In: Kočandrlová M, Kelar V, editors, Mathematical and computer modelling in science and engineering,CTU, 27–30.1.03, 2003. p. 339–343.