journal article·2009-04

Hydrothermal model for predicting fire-induced spalling in concrete structural systems

M.B. Dwaikat, V.K.R. Kodur

Fire Safety Journal· Volume 44· Issue 3
Publisher page

Abstract

A one-dimensional numerical model to predict fire-induced spalling in concrete structures is presented. The model is based on pore pressure calculations in concrete, as a function of time. Principles of mechanics and thermodynamics are applied to predict pore pressure in concrete structures exposed to fire. An assessment of the possibility of tensile fracture is made by comparing the computed pore pressure with temperature-dependent tensile strength. The pore pressure calculations are coupled with heat transfer analysis to ensure that the loss of concrete section, resulting from spalling, is accounted for in subsequent heat transfer analysis. The validity of the numerical model is established by comparing temperature, pore pressure, and concrete spalling predictions with results from fire tests. The computer program is applied to conduct case studies to investigate the influence of concrete permeability, tensile strength of concrete, relative humidity in concrete, and heating rate on fire-induced spalling in concrete members. Through these case studies, it is shown that permeability, tensile strength of concrete, and heating rate have a significant influence on fire-induced spalling in concrete. It is also shown that relative humidity has a marginal influence on fire-induced spalling in concrete.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Concrete Properties and Behavior · Engineering and Material Science Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. L.T. Phan, Fire performance of high-strength concrete: a report of the state-of-the-art, National Institute of Standards and Technology, Gaithersburg, MD, 1996, p. 105.10.6028/NIST.IR.5934 ↗
2. U. Diederichs, U.M. Jumppanen, U. Schneider, High temperature properties and spalling behaviour of HSC, in: Proceedings of the Fourth Weimar Workshop on HPC, HAB Weimar, Germany, 1995, pp. 219–235.
3. V.R. Kodur, M.A. Sultan, Structural behaviour of high strength concrete columns exposed to fire, in: Proceedings of the International Symposium on High Performance and Reactive Powder Concrete, Sherbrooke, Quebec, vol. 4, 1998, pp. 217–232.
4. Ulf. Danielsen, Marine concrete structures exposed to hydrocarbon fires, Report, SINTEF—The Norwegian Fire Research Institute, 1997, pp. 56–76.
5. Optimization of the type and amount of polypropylene fibres for preventing the spalling of lightweight concrete subjected to hydrocarbon fire10.1016/S0958-9465(03)00085-4 ↗
6. Limits of spalling of fire-exposed concrete10.1016/S0379-7112(02)00051-6 ↗
7. V.K.R. Kodur, Spalling in high strength concrete exposed to fire—concerns, causes, critical parameters and cures, in: ASCE Structures Congress Proceedings, Philadelphia, USA, 2000, pp. 1–8.10.1061/40492(2000)180 ↗
8. Critical factors governing the fire performance of high strength concrete systems10.1016/j.firesaf.2006.10.006 ↗
9. Guidelines for fire resistance design of high strength concrete columns10.1177/1042391505047740 ↗
10. Harmathy · 1993
11. Y. Anderberg, Spalling phenomenon of HPC and OC, in: Proceedings of the International Workshop on Fire Performance of High Strength Concrete, Gaithersburg, MD, 1997, NIST SP 919, pp. 69–75.
12. Z.P. Bazant, Analysis of pore pressure, thermal stress and fracture in rapidly heated concrete, in: Proceedings of the International Workshop on Fire Performance of High Strength Concrete, Gaithersburg, MD, 1997, NIST SP 919, pp. 155–164.
13. Numerical analysis of hygro-thermic behaviour and damage of concrete at high temperature10.1002/(SICI)1099-1484(199901)4:1<37::AID-CFM58>3.0.CO;2-S ↗
14. Finite element analysis of various methods for protection of concrete structures against spalling during fire10.1007/s00466-005-0024-7 ↗
15. Towards prediction of the thermal spalling risk through a multi-phase porous media model of concrete10.1016/j.cma.2005.10.021 ↗
16. Finite element analysis of coupled heat and moisture transfer in concrete subjected to fire10.1080/10407780152032839 ↗
17. Coupled heat and moisture transport in concrete at elevated temperatures—effects of capillary pressure and adsorbed water10.1080/10407780500503854 ↗
18. Predicting the fire resistance behavior of high strength concrete columns10.1016/S0958-9465(03)00089-1 ↗
19. Eurocode 2, General rules—structural fire design, in: prEN1992-1-2: design of concrete structures, Part 1–2, Comité Europeén de Normalisation (CEN), Brussels, 2004.
20. ACI Committee 216.1 · 2007
21. Simultaneous moisture and heat transfer in porous systems with particular reference to drying10.1021/i160029a016 ↗
22. T.Z. Harmathy, Moisture and heat transport with particular reference to concrete, National Council of Canada, NRCC 12143, 1971.
23. Multi-phase moisture transfer in porous media subject to temperature gradient10.1016/0017-9310(79)90217-5 ↗
24. Heat and mass transfer in porous media subject to fire10.1016/0017-9310(79)90180-7 ↗
25. ASTM, Standard methods of fire test of building construction and materials, ASTM Test Method E119-01, American Society for Testing and Materials, West Conshohocken, PA, 2001.
26. ASTM, Standard test methods for determining effects of large hydrocarbon pool fires on structural members and assemblies, ASTM Test Method E1529, American Society for Testing and Materials, West Conshohocken, PA, 1993.
27. SFPE · 2004
28. Pore pressure and drying of concrete at high temperature10.1061/JMCEA3.0002404 ↗
29. Pore pressure in heated concrete walls: theoretical prediction10.1680/macr.1979.31.107.67 ↗
30. Finite element program for moisture and heat transfer in heated concrete10.1016/0029-5493(82)90040-1 ↗
31. Permeabiliteat und Prositaet von Beton bei hohen Temperaturen
32. M. Kanema, A. Noumowe, J. Gallias, R. Cabrillac, Permeability and mechanical properties of concrete at high temperatures, in: Concrete Under Severe Conditions: Environment and Loading, Proceedings of CONSEC’07, Tours, France.
33. Bazant · 1996
34. 1992
35. High-temperature behavior of HPC with polypropylene fibers: from spalling to microstructure10.1016/S0008-8846(01)00596-8 ↗
36. Characterization and identification of equilibrium and transfer moisture properties for ordinary and high-performance cementations materials10.1016/S0008-8846(99)00102-7 ↗
37. Franssen · 2005