journal article·2011-05Open access

Verification of the accuracy of CFD simulations in small-scale tunnel and atrium fire configurations

Nele Tilley, Pieter Rauwoens, Bart Merci

Fire Safety Journal· Volume 46· Issue 4

Abstract

Abstract In preparation for the use of computational fluid dynamics (CFD) simulation results as ‘numerical experiments’ in fire research, the agreement with experimental data for two different small-scale set-ups is discussed. The first configuration concerns the position of smoke-free height in case of fire with vertical ventilation in an atrium. The second set-up deals with the critical velocity for smoke backlayering in case of fire in a horizontally ventilated tunnel. An N -percent rule is introduced for the determination of the presence of smoke in the simulation results, based on the local temperature rise. The CFD package FDS is used for the numerical simulations. The paper does not scrutinize the detailed accuracy of the results, as this is hardly possible with any state-of-the-art experimental data at hand. Rather, the global accuracy is discussed with current numerical implementation and models in FDS, considering continuous evolution over different version releases with time. The agreement between the experiments and numerical simulations is very promising. Even when quantitative agreement with experimental data is not perfect, the trends are very well reproduced in the simulations. While much additional work is required, both in CFD as in ‘real’ experiments, the results are encouraging for the potential of state-of-the-art CFD to be used as numerical experiments.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Evacuation and Crowd Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Entrainment by adhered two-dimensional plumes10.1016/j.firesaf.2007.11.001 ↗
2. Control of smoke flow in tunnel fires using longitudinal ventilation systems—a study of the critical velocity10.1016/S0379-7112(00)00031-X ↗
3. McGrattan · 2008
4. McGrattan · 2008
5. Physical scale modelling of adhered spill plume entrainment10.1016/j.firesaf.2010.02.005 ↗
6. Air entrainment into balcony spill plumes10.1016/j.firesaf.2010.02.001 ↗
7. General circulation experiments with the primitive equations I. The basic experiment10.1175/1520-0493(1963)091<0099:GCEWTP>2.3.CO;2 ↗
8. Large eddy simulations of smoke movement10.1016/S0379-7112(97)00041-6 ↗
9. Thomas · 1963
10. Determination of interface height from measured parameter profile in enclosure fire experiment10.1016/S0379-7112(97)00064-7 ↗
11. An experimental study of upper hot layer stratification in full-scale multiroom fire scenarios10.1115/1.3245194 ↗
12. Determination of the smoke layer interface height for hot smoke tests in big halls10.1177/0734904108096852 ↗
13. Beard · 2005
14. The critical ventilation velocity in tunnel fires—a computer simulation10.1016/j.firesaf.2004.11.001 ↗
15. Application of RANS and LES field simulations to predict the critical ventilation velocity in longitudinally ventilated horizontal tunnels10.1016/j.firesaf.2008.02.002 ↗
16. Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires10.1016/j.firesaf.2010.07.003 ↗