Fire load and fire growth characteristics in modern high-rise buildings
Source abstract
Abstract
Fire load is the major contributor to the heat release rate, which defines the severity of a fire event in buildings. It is necessary to have a well-defined fire load for residential buildings to perform an adequate fire safety design. This study estimates the fire load and fire growth for modern residential apartments using survey results of 50 high-rise buildings in Istanbul, Turkey. The survey methodology is the inventory method primarily based on size measurements and photographic information obtained from physical visits to apartments and digital inventory of real-estate websites. Fire loads in living rooms, bedrooms, and kitchens form the basis of the study. Results show that the average fire load density in living rooms range from 310 MJ/m2 to 379 MJ/m2 whereas the range is within 518 MJ/m2 and 650 MJ/m2 for bedrooms. The kitchen has the average fire load density of 552 MJ/m2. Eurocode estimation of the fire load density for dwellings is found overly conservative compared to the survey results. The FDS results provide fire spread times of 1 min–11 min depending on the compartment. Cumulative fire growth curves for living rooms, bedrooms and kitchens are generated using fire load surveys and fire spread results.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire Detection and Safety Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Survey based fire load assessment and impact analysis of fire load increment on fire development in contemporary dwellings10.1016/j.ssci.2020.105094 ↗
2. Determination of fire load and heat release rate for high-rise residential buildings10.1016/j.proeng.2014.10.460 ↗
3. Palokuorman määrä kerrostalojen asuinhuoneistoissa
4. Campbell · 1981
5. Fire load in residential buildings10.1016/0360-1323(94)00043-R ↗
6. Movable fire load survey for old residential highrise buildings in Hong Kong10.2495/SAFE070211 ↗
7. Hietaniemi · 2010
8. Bwalya · 2004
9. Survey results of combustible contents and floor areas in Canadian multi-family dwellings10.1007/s10694-009-0130-8 ↗
10. 2002
11. Champneys · 2013
12. Klote · 2002
13. Estimation of rate of heat release by means of oxygen consumption measurements10.1002/fam.810040202 ↗
14. Ignitability measurements with the cone calorimeter10.1002/fam.810110103 ↗
15. Sundström · 1995
16. Hietaniemi · 2001
17. Axelsson · 2005
18. Walton · 1984
19. Babrauskas · 1979 · vol. 1103
20. Combustion characteristics of flat panel televisions with and without fire retardants in the casing10.1007/s10694-014-0420-7 ↗
21. Ahonen · 1984
22. Lawson · 1983
23. Pillow burning rates10.1016/0379-7112(85)90015-3 ↗
24. Sardqvist · 1993
25. Potato crisps and cheese nibbles burn fiercely
26. Stroup · 2003
27. Heat release rates of modern residential furnishings during combustion in a room calorimeter10.1002/fam.2259 ↗
28. McGrattan · 2006 · vol. 1018
29. Hurley · 2015
30. Assessing the sprinkler activation predictive capability of the Branzfire Fire Model10.1007/s10694-007-0009-5 ↗
31. Babrauskas · 1981
32. Chen · 2001
33. Determination of the critical heat flux for floating flooring
34. Analysis of principal gas products during combustion of polyether polyurethane foam at different irradiance levels10.1016/j.firesaf.2009.05.003 ↗