journal article·2001-09

Variation of heat release rate with forced longitudinal ventilation for vehicle fires in tunnels

R.O. Carvel, A.N. Beard, P.W. Jowitt, D.D. Drysdale

Fire Safety Journal· Volume 36· Issue 6
Publisher page

Abstract

Many tunnels are equipped with longitudinal ventilation systems to control smoke in the event of a fire. However, the influence of such ventilation on fire development and fire spread has rarely been considered. This paper presents the results of a study using a Bayesian methodology to estimate the effect of forced longitudinal ventilation on heat release rate (HRR) for fires in tunnels. The behaviour of car and heavy goods vehicle (HGV) fires with a range of forced ventilation velocities is investigated. Results are presented and the implications are discussed. It has been found that forced ventilation has a great enhancing effect on the HRR of HGV fires, but has little effect on the HRR of car fires.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire effects on ecosystems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Pucher K, Pucher R. Fire in the Tauern tunnel. International Tunnel Fire & Safety Conference, Hilton Hotel, Rotterdam, Netherlands, 2–3 December 1999. Organised by Brisk Events. Paper number 8.
2. Lacroix D. Fire in the Mont Blanc tunnel: facts and lessons. International Tunnel Fire & Safety Conference, Hilton Hotel, Rotterdam, Netherlands, 2–3 December 1999. Organised by Brisk Events. Paper number 9.
3. Allison R. (Chair) Inquiry into the fire on heavy goods vehicle shuttle 7539 on 18 November 1996. HMSO, 1997. ISBN: 011–551931–9.
4. Hedefalk J, Wahlstrom B, Rohlen P. Lessons from the Baku subway fire. Third International Conference on Safety in Road and Rail Tunnels, Nice, France, 9–11 March 1998. p. 15–28.
5. Danziger NH, Kennedy WD. Longitudinal ventilation analysis for the Glenwood Canyon Tunnels. Fourth International Symposium on the Aerodynamics and Ventilation of Vehicle Tunnels, BHRA Fluid Engineering, 1982. p. 169–86.
6. Wu Y, Bakar MZA, Atkinson GT, Jagger S. A study of the effect of tunnel aspect ratio on control of smoke flow in tunnel fires. Ninth International Conference on Aerodynamics and Ventilation of Vehicle Tunnels, Aosta Valley, Italy, 6–8 October 1997. p. 573–87.
7. Fire and life safety for underground facilities10.1016/S0886-7798(98)00058-3 ↗
9. Memorial Tunnel Fire Ventilation Test Programme, Interactive CD-ROM & Comprehensive Test Report. Parsons Brinckerhoff 4D Imaging, 1996.
10. Proceedings of the one day Seminar on Smoke and Critical Velocity in Tunnels, London, 2 April 1996. Organised by Independent Technical Conferences Ltd.
11. Heselden AJM. Studies of fire and smoke behaviour relevant to tunnels. Paper CP66/78, Building Research Establishment, UK, 1978.
12. Lupton B. Unprotected long road tunnels: can least cost be justified or are such tunnels an accident waiting to happen? International Conference on Tunnel and Underground Station Fires, 3–4 May 2000, Hong Kong. p. 21–32.
13. Grant GB, Drysdale DD. Estimating heat release rates from large scale tunnel fires. Proceedings of the Fifth International Symposium on Fire Safety Science, Melbourne, Austrailia, 3–7 March 1997. p. 1213–24.10.3801/IAFSS.FSS.5-1213 ↗
14. Carvel RO, Beard AN, Jowitt PW. A Bayesian estimation of the effect of forced ventilation on a pool fire in a tunnel. Civil Engng Environ Systems 2001;18(4).10.1080/02630250108970305 ↗
15. Ang AH-S, Tang WH. The Bayesian approach. In: Probability concepts in engineering planning and design, vol. 1. New York: Wiley, 1975. p. 284–91.
16. Bayesian analysis in regression problems
17. Casale E, Marlair G. Heptane fire tests with forced ventilation. Proceedings of the International Conference on Fires in Tunnels, Borås, 10–11 October 1994. p. 37–50.
18. Saito N, Yamada T, Sekizawa A, Yanai E, Watanabe Y, Miyazaki S. Experimental study on fire behaviour in a wind tunnel with a reduced scale model. Second International Conference on Safety in Road and Rail Tunnels, Granada, Spain, 1995. p. 303–10.
19. Fires in transport tunnels: report on full-scale tests. EUREKA-Project EU499:FIRETUN Studiengesellschaft Stahlanwendung e.V. D-40213 Dusseldorf, 1995.
20. Steinert C. Smoke and heat production in tunnel fires. Proceedings of the International Conference on Fires in Tunnels, Borås, 10–11 October 1994. p. 123-37.
21. Bettis RJ, Jagger SF, Moodie K. Reduced scale simulations of fires in partially blocked tunnels. Proceedings of the International Conference on Fires in Tunnels, Borås, Sweden, 10–11 October 1994. p. 163–86.
22. Perard M. Organization of fire trials in an operated road tunnel. First International Conference on Safety in Road and Rail Tunnels, Basel, Switzerland, 23–25 November 1992. p. 161–70.
23. Keski-Rahkonen O, Holmjund C, Loikkanen P, Ludvigsen H, Mikkola E. Two full scale pilot experiments in a tunnel. VTT Research Report 453. VTT, Finland, 1986.
24. Ingason H, Nireus K, Werling P. Fire tests in a blasted rock tunnel. Report FOA-R–97–00581–990–SE. FOA, Sweden, 1997.
25. Bettis RJ, Wu Y, Hambleton RT. Interim validation of tunnel fire consequence models: data from phase 2, Test 5. Section paper IR/L/93/09 (part 5), HSE, Buxton.
26. Scaling applications in fire research10.1016/0379-7112(89)90045-3 ↗
27. Carvel RO, Beard AN, Jowitt PW. The effect of forced longitudinal ventilation on a HGV fire in a tunnel. Proceedings of the International Conference on Tunnel Fires, Lyon, France, May 5–6, 1999. p. 191–200.
28. Luchian S. In: The Introduction to the MTFVTP report (9), vol. 1, p. 1.1.
29. Howson · 1989
30. Apostolakis G, Kazarians M. The frequency of fires in light water reactor compartments. Proceedings of the American Nuclear Society/European Nuclear Society Topical Meeting: Thermal Reactor Safety, Knoxville, TN, April 6–9, 1980. p. 72–9.
31. Water supply and pollution control