journal article·2006-09

Influence of tunnel width on longitudinal smoke control

O. Vauquelin, Y. Wu

Fire Safety Journal· Volume 41· Issue 6
Publisher page

Abstract

The objective is to carry out experiments on scale models and CFD calculations in order to study the influence of tunnel width W on critical velocity (for a given tunnel height H). By definition, the critical velocity is the minimum longitudinal velocity needed to prevent smoke back flow when a fire occurs in a tunnel. Two different experimental reduced scale models are used: the first one is a thermal model using a propane gas flame to simulate the fire and the second one is a densimetrical model in which the fire-induced- smoke is represented by a continuous release of an isothermal buoyant mixing. In both approaches, for aspect ratios W/H greater than unity, it is noticed that the critical velocity decreases when the width increases, as predicted by theory, but for low values of the aspect ratio (i.e. when W less than H) and for high enough fire heat release rates, the critical velocity significantly increases with tunnel width. This can be associated to a change in the transverse flow pattern close to the buoyant source. Complementary CFD calculations are also presented in order to describe the influence of the lateral confinement on smoke plume spreading and then, on critical velocity.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Evacuation and Crowd Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. Thomas PH. The movement of smoke in horizontal passages against an air flow. Fire Research Station Note no. 723, Fire Research Station, 1968.
2. Danziger NH, Kennedy WD, Longitudinal ventilation analysis for the Glenwood Canyon tunnels. In: Fourth international symposium on aerodynamics and ventilation of vehicle tunnels, BHr Group, 1982; p. 169–186.
3. Simple model for control of fire gases in a ventilated tunnel10.1016/S0379-7112(01)00020-0 ↗
4. Control of smoke flow in tunnel fires10.1016/0379-7112(96)00007-0 ↗
5. Control of smoke flow in tunnel fires using longitudinal ventilation systems—a study of the critical velocity10.1016/S0379-7112(00)00031-X ↗
6. A model to evaluate tunnel fire characteristics10.1016/S0379-7112(00)00010-2 ↗
7. The numerical computation of turbulent flows10.1016/0045-7825(74)90029-2 ↗
8. Ljuboja M, Rodi W, Prediction of horizontal and vertical turbulent buoyant wall jets. J Heat Transfer Trans. ASME 1981.10.1115/1.3244464 ↗