Modeling for predicting the temperature distribution of smoke during a fire in an underground road tunnel with vertical shafts
Source abstract
Abstract
In this study, fire experiments using a 1:20 model-scale tunnel were conducted to investigate the performance of natural ventilation in an underground road tunnel with six vertical shafts. The experimental parameters were the heat release rate of a fire source and the height of the shafts, and nine experiments were conducted in total. Furthermore, simple models were developed for predicting the temperature distribution of the smoke flowing under the tunnel ceiling. The following results were obtained: (1) In the experiments, the form of the smoke exhausted from the shaft became plug-holing when the shaft height was 1.0Ht, and became boundary layer separation when the height was 0.24Ht. (2) The average efficiency of heat exhaust was 0.16 when the form was plug-holing, and was 0.12 when the form was boundary layer separation. (3) When the form was plug-holing, the ratio of entrainment of fresh air became almost constant regardless of Ri. On the other hand, when the form was boundary layer separation, the ratio of entrainment of fresh air was smaller than that under the condition of plug-holing. (4) The temperature distribution under the tunnel ceiling predicted by the models agreed with that measured by the fire experiments in all cases.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire effects on ecosystems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. A study of the effect of plug-holing and boundary layer separation on natural ventilation with vertical shaft in urban road tunnel fires10.1016/j.ijheatmasstransfer.2012.06.014 ↗
2. Experimental study of air entrainment mode with natural ventilation using shafts in road tunnel fires10.1016/j.ijheatmasstransfer.2012.09.047 ↗
3. Effects of vertical shaft arrangement on natural ventilation performance during tunnel fires10.1016/j.ijheatmasstransfer.2014.02.003 ↗
4. Determination of interface height from measured parameter profile in enclosure fire experiment10.1016/S0379-7112(97)00064-7 ↗
5. Experimental investigation on influence of different transverse fire locations on maximum smoke temperature under the tunnel ceiling10.1016/j.ijheatmasstransfer.2012.04.052 ↗
6. Critical velocity and range of a fire-gas plume in a ventilated tunnel10.1016/S1352-2310(98)00118-6 ↗
7. Entrainment in fire plumes10.1016/0379-7112(81)90037-0 ↗
8. Simulation of back-layering length in tunnel fire with vertical shafts10.1016/j.applthermaleng.2016.08.081 ↗
9. ceiling jet flows
10. Simple model for control of fire gases in a ventilated tunnel10.1016/S0379-7112(01)00020-0 ↗
11. H. Hengdong, The countermeasures to the pollutions of smoke o high temperature in passageway of underground buildings, Proceedings of the 1st Asia-Oceania Symposium on Fire Science &Technology (AOFST 1), 1992, pp. 221–226.