journal article·2007-09

Performance of cellular composite floor beams at elevated temperatures

Ali Nadjai, Olivier Vassart, Faris Ali, Didier Talamona, Ahmed Allam, Mike Hawes

Fire Safety Journal· Volume 42· Issue 6-7
Publisher page

Abstract

This paper describes an experimental and numerical study at both ambient and elevated temperatures on the behaviour of full-scale composite floor cellular steel beams. A total of four specimens, comprising two different steel geometries and loading conditions were tested under monotonic loading and at elevated temperatures. All beams were designed for a full shear connection between the steel beam and the concrete flange using headed shear studs. The beams were designed to fail by web-post buckling, which was observed in all the tests. Failure temperature observed in the fire tests indicated that failure by web-post buckling of cellular beams in fire cannot simply be estimated by applying temperature dependent reduction factors on stiffness, as given in codes. A finite element model is then established with both material and geometrical non-linearity using shell elements to compare against the experimental results. The comparison between the finite element prediction and actual test results are quite good in terms of failure modes, load deflection behaviour and ultimate loads.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. Properties and strength of castellated beams. Consideration of previous tests. Report D.GE. 71/262, The United Steel Companies Ltd, Swinden Laboratories, Rotherham; 1957.
2. An investigation of the stresses and deflections in castellated beams
3. Sherbourne AN. The plastic behaviour of castellated beams. Proceedings of the second commonwealth welding conference, Institute of Welding, No. C2, London; 1966. p. 1–5.
4. Delesques R. Stabilité des montants de poutres ajourées. Revue construction métallique, vol. 3 CTICM, 1968. p. 26–33.
5. Bazile A, Texier J. Essais de poutres ajourées. Revue construction métallique, vol. 3 CTICM, 1968. p. 12–25.
6. Experiments on castellated steel beams
7. Stress distribution in castellated beams10.1061/JSDEAG.0002956 ↗
8. Elastic flexural stress distribution in webs of castellated steel beams
9. Redwood RG. Analyse et dimensionnement des poutres ayant des ouvertures dans les âmes. Revue construction métallique, vol. 3, CTICM, 1978. p. 15–27.
10. Mateesco D, Mercea G. Un nouveau type de poutres ajourées. Revue construction métallique, vol. 3, CTICM, 1981. p. 3–14.
11. Finite element analysis of castellated beams10.1016/0045-7949(78)90135-9 ↗
12. Stress analysis of castellated beams
13. Kerdal D. Lateral torsional buckling of castellated steel beams. PhD thesis, University of Sheffield, UK, November 1982.
14. Kerdal D, Nethercot DA. Lateral torsional buckling of castellated steel beams—design of test beams. Research report no. BE22/2/065/2, submitted to DTP, BED, September 1978.
15. Failure modes for castellated beams10.1016/0143-974X(84)90004-X ↗
16. Web post strength in castellated beams10.1680/iicep.1985.837 ↗
17. Design of castellated beams10.1680/iicep.1991.14728 ↗
18. Dougherty BK. Ultimate load design curves for castellated universal beams. Research report no. 6, Department of Civil Engineering, University of Natal, Durban, March 1980.
19. Zaarour W, Redwood R. Web buckling in thin webbed castellated beams. J Struct Eng 1996. p. 860–6.10.1061/(ASCE)0733-9445(1996)122:8(860) ↗
20. Megharief J, Redwood GR. Composite floor systems using castellated beams. Proceedings of the annual conference, Canadian Society for Civil Engineering, 1997. p. 239–48.
21. Fire protection for structural steel in buildings, 2nd ed., ASFP/SCI/FTSG, 1992.
22. Indicative fire tests to investigate the behaviour of cellular beams protected with intumescent coatings10.1016/j.firesaf.2004.06.007 ↗
23. RT1006 version 02: fire design of cellular beams with slender web posts. Ascot: SCI; 2004.
24. Newman GM, Robinson JT, Bailey CG. Fire safe design: A new approach to multi-storey steel-framed buildings, 2nd ed., Ascot: SCI Publication P288, The Steel Construction Institute; 2006.
25. Bitar D, Demarco T, Martin PO. Steel and non-composite cellular beams—novel approach for design based on experimental studies and numerical investigations. Brochure. EUROSTEEL, 2005.
26. Large web openings for service integration in composite floor. ECSC contract 7210- PR-315, 2004.