Differences in measurement methods for travel distance and area for estimates of occupant speed on stairs
Source abstract
Abstract
Abstract Many previous studies have reported that the density in the stairs affects the achievable speed of the population using them. To measure the speed, one value that needs to be known is the distance. Similarly, to measure the density, one value that needs to be known is the area used by the population. Previous studies have used different methods to calculate these values and this paper reviews some of these different methods. Comparisons are made between these methods to show the difference in results that can result simply using data and equations developed using different assumptions. Then theoretical equations are developed for the travel distance and area based on how people have previously been observed traveling along arcs while crossing landings on stairs. Finally, the effects of misusing the different methods for calculating travel distance and area are compared using data from an actual building evacuation drill. It is shown that misusing methods can lead to significantly different results for the same data.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Evacuation and Crowd Dynamics · Smart Parking Systems Research · Urban Transport and Accessibility
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. National Fire Protection Association · 2009
2. M. Galbreath, Time of Evacuation by Stairs in High Buildings, National Research Council of Canada, Fire Research Note, no.8, May 1969.
3. London Transport Board, Second Report of the Operational Research Team on the Capacity of Footways, London Transport Board Research Report no.95, August 1958.
4. J.L. Pauls, Evacuation Drill Held in the BC Hudro Building 26 June 1969, National Research Council Canada, Building Research Report 80, 1971.
5. Predtechenskii · 1978
6. Building evacuation:research findings and recommendations
7. Fruin · 1987
8. G. Proulx, N. Bénichou, J.K. Hum, K.N. Restivo, Evaluation of the Effectiveness of Different Photoluminescent Stairwell Installations for the Evacuation of Office Building Occupants, National Research Council Canada, Research Report 232, 2007.
9. Overall and local movement speeds during fire drill evacuations in buildings up to 31 stories
10. Evacuation and other fire safety measures in high-rise buildings
11. J.L. Pauls, Management and movement of building occupants in emergencies, National Research Council of Canada, Division of Building Research Paper 788, 1978.
12. Building evacuation: research methods and case studies
13. The movement of people in buildings and design solutions for means of egress10.1007/BF02390046 ↗
14. Evacuation time and movement in apartment buildings10.1016/0379-7112(95)00023-M ↗
15. G. Proulx, J.C. Latour, J.W. Maclaurin, J. Pineau, L.E. Hoffman, C. Laroche, Housing Evacuation of Mixed Ability Occupants in Highrise Buildings, National Research Council of Canada, Internal Report 706, 1995.
16. G. Proulx, A. Kaufman, J. Pineau, Evacuation Times and Movement in Office Buildings, National Research Council of Canada, Internal Report 711, 1996.
17. G. Proulx, D.K. Tiller, B. R. Kyle, J. Creak, Assessment of Photoluminescent Material During Office Occupant Evacuation, National Research Council of Canada, Internal Report 774, 1999.
18. Templer · 1992
19. J.A. Templer, Stair Shape and Human Movement, Ph.D. Dissertation, Columbia University, 1975.
20. Calculating and verifying the staircase-length for evacuation analysis
21. E.D. Kuligowski, R.D. Peacock, Building Occupant Egress Data, Report of Test FR 4024, National Institute of Standards and Technology, Gaithersburg, MD, 2010.