Concerns have been raised about the environmental impact of fluorocarbon-based fire fighting foams. To aid in developing alternative fire fighting foam formulations, fire suppression models are being constructed to evaluate the performance of new, innovative formulations. Some of the input parameters for the fire suppression models are specific to the foam and need to be measured experimentally. A small-scale test apparatus was developed in this study to measure the foam loss mechanisms (i.e., solution evaporated and drained) as well as the time to fuel ignition. In this test, the mass evaporated and drained is continuously measured for a static layer of foam exposed to a fixed irradiance level. The test apparatus was used to quantify the behavior of a single formulation of MIL-SPEC 6% aqueous film-forming foam (AFFF) for a variety of test conditions. Methods for using the data from the small-scale testing in fire suppression models were developed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Combustion and Detonation Processes · Flame retardant materials and properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Hanauska CP. Environmental issues affecting foam use. Presentation to the National Fire Protection Association World Fire Safety Congress, Denver, CO, USA, 14 May, 2001.
2. Foam and the Environment
3. MIL-F-24385F. Fire extinguishing agent, aqueous film-forming foam (AFFF) liquid concentrate for fresh and sea water. Military Specification, January, 7, 1992.
4. UL 162. Standard for foam equipment and liquid concentrates, 17th ed. Northbrook, IL: Underwriters Laboratories, Inc., 1994.
5. Scheffey JL, Wright JA. Analysis of test criteria for specifying foam fire fighting agents for aircraft rescue and firefighting. FAA Technical Report, DOT/FAA/CT-94/04, Atlantic City, NJ, August 1994.
6. Severe laboratory fire test for fire fighting foams10.1007/BF01857840 ↗
7. Hanauska CP, Scheffey JL, Roby RJ, Gottuk DT. Improved formulations of firefighting agents for hydrocarbon fuel fires. Hughes Associates, Inc. SBIR Phase I Final Report for US Air Force, January 1994.
8. Persson H. FAIRFIRE—a small-scale fire test method for fire fighting foams. Proceedings from NFPRF Fire Suppression and Detection Symposium, Orlando, Florida, February 12–14, 1997.
9. Persson B, Dahlberg M. A simple model of foam spreading on liquid surfaces. SP Report 1994:27, Swedish National Testing and Research Institute, Boras, Sweden, 1994.10.3801/IAFSS.FSS.4-265 ↗
10. Isaksson S, Persson H. Fire extinguishing foam—test method for heat exposure characterisation. SP Report 1997:09, Swedish National Testing and Research Institute, Boras, Sweden, 1997.
11. Persson H. Fire extinguishing foams-resistance against heat radiation. SP Report 1992:54, Swedish National Testing and Research Institute, Boras, Sweden, 1992.
12. Persson H, Milovancevic M. FAIRFIRE, fire fighting foams: small scale test procedure, improvement of drainage and expansion methodology. SP Report 1996:28, Swedish National Testing and Research Institute, Boras, Sweden, 1996.
13. Magrabi SA, Dlugogorski BZ, Jameson GJ. Attenuation of thermal radiation by aqueous foam. Proceedings of the 24th Australia and New Zealand Chemical Engineering Conference, Rororua, New Zealand, September 29–October 1, SF2a:319 1997.
14. ISO 5660-1. Fire tests—reaction to fire: Part 1: rate of heat release from building products (cone calorimeter method). International Standard Organization, Geneva, Switzerland, 1993.
15. SFPE, Engineering Guide—assessing flame radiation to external targets from pool fires. SFPE Task Group on Engineering Practices, C.L. Beyler, Chairman, Society of Fire Protection Engineering, Bethesda, MD, June, 1999.
16. Mudan KS, Croce PA. Fire hazard calculations for large open hydrocarbon pool fires. In: DiNenno PJ, editor. The SFPE handbook for fire protection engineers. Boston, MA: SFPE, 1995 [Section 3, Chapter 11].
17. Tewarson A. Generation of heat, chemical compounds in fires. In: DiNenno PJ, editor. The SFPE handbook for fire protection engineers. Boston, MA: SFPE, 1995 [Section 3, Chapter 4].
18. 3M, Material Safety Data Sheet for FC-206CF Light Water™ AFFF 6%, St. Paul, MN, 2000.
19. Persson B, Lonnermark A, Persson H, Mulligan D, Lancia A, Demichela M. FOAMSPEX large scale foam application—modelling of foam spread and extinguishment. SP Report 2001:13, Boras, 2001.
20. Free drainage in aqueous foams10.1002/aic.690470210 ↗
21. The foam drainage equation10.1088/0953-8984/8/21/002 ↗
22. Dynamics of coarsening foams10.1103/PhysRevLett.86.4704 ↗