journal article·2019-10

Exploring the fire behaviour of thin intumescent coatings used on timber

Andrea Lucherini, Qazi Samia Razzaque, Cristian Maluk

Fire Safety Journal· Volume 109
Publisher page

Abstract

The study presented herein describes an exploratory investigation on the fire performance of intumescent coatings used on timber elements. Timber samples, uncoated or coated with three different thicknesses of a commercially available thin intumescent coating, were tested using high-performance radiant panels according to the H-TRIS fire test method. Test samples were heated for 60 min at a constant incident radiant heat flux of 50 kW/m. Uncoated samples quickly ignited, while coated samples showed good adherence between the intumescent coating and the timber substrate and limited flaming. At the start of the heating exposure, the intumescent coating rapidly swelled up to a quasi-steady thickness. The presence of the intumescent coating at the exposed surface of timber samples seemed to delay the onset of timber charring and also to reduce the average charring rate after initiation of charring. The delay is proportional to the DFT of the intumescent coating, up to 40 min from the start of heating for a DFT of 2.1 mm (based on 300 °C isotherm). The experimental results described herein showed that thin intumescent coatings may be effectively used on timber for delaying the onset of charring and assuming a reduced timber charring rate during heating.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Flame retardant materials and properties · Fire dynamics and safety research · Wood Treatment and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Tall timber buildings: what’s next in fire safety?10.1007/s10694-015-0497-7 ↗
2. White · 2010
3. Comité Europeén de Normalization (CEN) · 2004
4. Buchanan · 2017
5. Intumescent coatings: a review on recent progress10.1007/s11998-016-9815-3 ↗
6. Recent developments of intumescent fire protection coatings for structural steel: a review10.1177/0734904115626720 ↗
7. Thermal analysis of intumescent coatings
8. Synthesis and application of novel magnesium phosphate ester flame retardants for transparent intumescent fire-retardant coatings applied on wood substrates10.1016/j.porgcoat.2019.01.013 ↗
9. An experimental study of solid timber external wall performance under simulated bushfire attack10.1016/j.buildenv.2009.03.005 ↗
10. Hakkarainen · 2010
11. Russell · 2007
12. Effects of natural weathering on the fire properties of intumescent fire‐retardant coatings10.1002/fam.2506 ↗
13. A brief review of intumescent fire retardant coatings10.1080/00038628.2003.9696967 ↗
14. Fire-retardant and smoke-suppressant performance of an intumescent waterborne amino-resin fire-retardant coating for wood10.1007/s11461-008-0075-y ↗
15. The thermal characteristics of different intumescent coatings10.1002/(SICI)1099-1018(199901/02)23:1<33::AID-FAM667>3.0.CO;2-Z ↗
16. Effects of intumescent formulation for acrylic-based coating on flame-retardancy of painted red lauan (Parashorea spp.) thin plywood10.1007/s00226-008-0197-2 ↗
17. International Organization for Standardization (ISO) · 2002
18. Comparative experimental study of fire-resistance ratings of timber assemblies with different fire protection measures10.1177/1369433216630044 ↗
19. A heat-transfer inducing system (H-TRIS) test method10.1016/j.firesaf.2016.05.001 ↗
20. Novel testing to study the performance of intumescent coatings under non-standard heating regimes
21. Novel test methods for studying the fire performance of thin intumescent coatings
22. Assessing the onset of swelling for thin intumescent coatings under a range of heating conditions10.1016/j.firesaf.2019.03.014 ↗
23. Description of small and large-scale CLT fire tests10.1016/j.firesaf.2017.03.024 ↗
24. Drysdale · 2011
25. Experimental study of the performance of intumescent coatings exposed to standard and non-standard fire conditions10.1016/j.firesaf.2017.10.004 ↗
26. Structural capacity in fire of laminated timber elements in compartments with exposed timber surfaces10.1016/j.engstruct.2018.10.084 ↗
27. Investigation of different temperature measurement design and installations in timber members as low conductive material