Fire induced pressure in airthigh houses: Experiments and FDS validation
Source abstract
Abstract
Abstract The need for sustainability and smaller ecological footprint lead to the construction of more airtight building envelopes with better thermal insulation in order to increase the energy efficiency of houses, according to the Energy Performance of Buildings Directive. The specific fire hazards possibly associated with such structures raised questions amongst fire community in Belgium. A full-scale experimental facility was built in the region of Mons to study the effects of both the airtightness of the building envelope and the mechanical ventilation on fire hazards and especially on fire induced pressure. Two different ventilation duct configurations were tested: one with mechanical ventilation on, the other one with the ducts closed with an airtight metal cap, the mechanical ventilation being off. Measurements were made for gas pressure, mass loss rate, gas temperature, volumetric flow rate in the ducts and for some tests O2, CO2, CO and THC concentrations were also quantified. Pressure peaks from 870 to 2035 Pa were measured without mechanical ventilation (ducts closed), while values from 420 to 750 Pa were observed with the mechanical ventilation on. The mechanical ventilation network is not sufficient to prevent pressure inside the rooms. The occupants may not succeed in escaping during a period of several minutes due to the impossibility to open inward opening doors linked to this fire induced pressure. This experimental campaign was also used for validating the field model FDS version 6.5.0 predictive capability. The effective loss coefficients of the HVAC system were calculated from all the components of the ventilation network without the need of estimation from initial pressure data. Moreover, the variation of the effective leakages area of the setup as function of fire induced pressure has to be taken into account in the pressure zone modelling in order to obtain satisfactory simulation results compared to the experimental measurements. Consequently, in addition to classical blower door tests, pressurization tests up to 600 Pa were also carried out in order to measure the effective leakages area as function of pressure according to ASTM E779. This new capability was implemeted by the developers of FDS since the 6.5.0 version. The use of validated software could be helpful to take into account the fire-induced pressure in confined dwellings in fire safety design.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Wind and Air Flow Studies · Combustion and Detonation Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Directive of the European Parliament and of the Council of 19 May 2010 on the Energy Performance of Buildings. (Directive 2010/31/EU).
2. Hume · 2004
3. Modelling a backdraft: the fire at 62 watts street
4. Comparison of fire hazards in passive and conventional houses
5. Numerical simulation of pressure changes in closed chamber fires10.1016/j.buildenv.2008.09.016 ↗
6. Pressure variations induced by a pool fire in a well-confined and force-ventilated compartment10.1016/j.firesaf.2012.04.005 ↗
7. Validation of FDS for large-scale well-confined mechanically ventilated fires scenarios with emphasis on predicting ventilation system behavior10.1016/j.firesaf.2013.07.007 ↗
8. Computer simulations to study interaction between burning rates and pressure variations in confined enclosure fires10.1016/j.firesaf.2013.01.030 ↗
9. Coupling a neywork HVAC model to a computational fluid dynamics odel using large eddy simulation10.3801/IAFSS.FSS.10-459 ↗
10. Van den Brink · 2015
11. Experiments and numerical simulations of pressure effects in apartment fires10.1007/s10694-016-0641-z ↗
12. Fire-induced pressure and smoke spreading in mechanilly ventilated buildings with air-tight envelopes10.1016/j.firesaf.2017.04.006 ↗
13. Inwards doors blocked by fire induced overpressure in airtight apartment: a real case in Germany
14. Vanhaverbeke · 2015
15. Fire-induced pressure in passive houses: experiments and FDS validation
16. Peacock · 2008 · vol. 1041
17. 1991
18. Comments on the role of leakages in field modelling of under-ventilated compartment fires10.1016/S0379-7112(99)00005-3 ↗
19. ASTM E779-19 · 2019
20. McGrattan · 2017 · vol. 1019
21. Genereation of heat and chemical compounds in fires, chapter 3-4
22. Measuring rate of heat release by oxygen consumption10.1007/BF01038449 ↗
23. Fire calorimetry relying on the use of the fire propagation apparatus. Part I: early learning from use in europe10.1002/fam.896 ↗
24. Computational fluid dynamics modelling of fire10.1080/10618562.2012.659663 ↗
25. McGrattan · 2017 · vols. 1018–1
26. Chapter 4-2
27. Pressure loss of orifice plates according to ISO 5167-110.1016/S0955-5986(97)00014-9 ↗
28. The orifice plate discharge coefficient equation - further work10.1016/0955-5986(94)00001-O ↗
29. The effect of oxygen concentration on CO and smoke produced by flames
30. Ventilation effects on compartment fire characterization, fire safety science
31. The effect of oxygen concentration on CO and soot yields in fires10.1002/fam.960 ↗
32. Peacock · 2011 · vol. 1026
33. Overpressure induced by fires in airtight buildings10.1088/1742-6596/1107/4/042031 ↗
34. Influence of thermocouple thermal inertia in impingement heat transfer experiments using transient techniques
35. Drysdale D · 2011