Abstract External building facade fires from window of under-ventilated enclosure fire poses a serious fire hazard to upper floors. This paper investigates specially the constraint effects of a sloping facing wall (similar to hillside building with a hillside slope nearby) on the external facade flame behavior, which is quite different from that with no such constraint boundaries. Experiments are carried out in a 0.4 m cubic scale enclosure fire model with various window geometries and a sloping facing wall at different sloping angles from horizontal level. It is found that, the gas temperature inside the enclosure is nearly uniform both with and without sloping facing wall. The facade flame height increases with the increase in sloping wall angle, especially as it is over 60°. Non-dimensional models are proposed to correlate the flame heights with the sloping facing wall angles. The change of heat flux upon the facade with sloping facing wall angle shows similar behavior as flame height. The variation of heat flux is then found to be well accounted for by change of flame height accordingly for different sloping facing wall angles with a proposed correlation.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Wind and Air Flow Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Assessment of the fire toxicity of building insulation materials10.1016/j.enbuild.2010.10.015 ↗
2. S. Yokoi, Study on the Prevention of Fire Spread Caused by Hot Upward Current, Report 34, Report of the Building Research Institute, Japan, 1960.
3. The projection of flames from burning buildings10.1007/BF02591612 ↗
4. The projection of flames from buildings on fire
5. I. Oleszkiewicz, Heat transfer from a window fire plume to a building facade, HTD-Collected Papers in Heat Transfer, vol. 123, Book no. H00526, 1989.
6. A new correlation for gas temperature inside a burning enclosure10.1016/j.firesaf.2009.06.009 ↗
7. K. Kawagoe, Fire Behaviour in Rooms, Report no. 27, Building Research Institute, Tokyo, 1958.
8. Modeling the trajectory of window flames with regard to flow attachment to the adjacent wall10.1016/j.firesaf.2008.06.007 ↗
9. The role of thermal radiation on the initiation of flashover in a compartment fire10.1016/j.ijheatmasstransfer.2004.05.017 ↗
10. A room fire model for predicting fire spread by external flames10.3210/fst.18.11 ↗
11. Heat flux from flames to vertical surfaces10.1007/BF01040003 ↗
12. Heat fluxes and flame heights in facades from fires in enclosures of varying geometry10.1016/j.proci.2006.08.033 ↗
13. Lee · 2006
14. Heat fluxes on opposite building wall by flames emerging from an enclosure10.1016/j.proci.2008.06.130 ↗
15. Heat flux profile upon building facade with side wall constraint due to window ejected fire plume: an experimental investigation and global correlation10.1016/j.firesaf.2014.08.001 ↗
16. An experimental investigation and statistical characterization of intermittent flame ejecting behavior of enclosure fires with an opening10.1016/j.combustflame.2011.09.018 ↗
17. Goble · 2007
18. Experimental study on flame height and temperature profile of buoyant window spill plume from an under-ventilated compartment fire10.1016/j.ijheatmasstransfer.2011.08.045 ↗
19. K.H. Lu, L.H. Hu, M.A. Delichatsios, F. Tang, Z.W. Qiu, L.H. He, Merging behavior of facade flames ejected from two windows of an under-ventilated compartment fire, Proc. Combust. Inst., http://dx.doi.org/10.1016/j.proci.2014.05.08310.1016/j.proci.2014.05.083 ↗
20. The physics of the outflow from the opening of an enclosure fire and re-examination of Yokoi's correlation10.1016/j.firesaf.2012.01.001 ↗
21. A mathematical model on lateral temperature profile of buoyant window spill plume from a compartment fire10.1016/j.ijheatmasstransfer.2012.08.040 ↗
22. Temperature profiles of window jet plume10.3210/fst.24.17 ↗
23. An experimental investigation on temperature profile of buoyant spill plume from under-ventilated compartment fires in a reduced pressure atmosphere at high altitude10.1016/j.ijheatmasstransfer.2012.05.058 ↗
24. Global behaviors of enclosure fire and facade flame heights in normal and reduced atmospheric pressures at two altitudes10.1016/j.ijheatmasstransfer.2012.09.050 ↗
25. A. Yanagisawa, D. Goto, Y. Ohmiya, M.A. Delichatsios, Y.P. Lee, K. Wakatsuki, Effect of a facing wall on facade flames, in: Proceedings of the 9th International Symposium on Fire Safety Science, Germany, 2008.10.3801/IAFSS.FSS.9-801 ↗
26. Experimental investigation on window ejected facade flame height with different constraint side wall length in building fire and global correlation10.1016/j.ijheatmasstransfer.2014.06.060 ↗
27. A global non-dimensional factor characterizing side wall constraint effect on facade flame entrainment and flame height from opening of compartment fires10.1016/j.ijheatmasstransfer.2014.03.059 ↗
28. Numerical studies on smoke spread in the cavity of a double-skin facade10.3846/13923730.2011.595075 ↗
29. Experimental study of fire growth in a reduced-scale compartment under different approaching external wind conditions10.1016/j.firesaf.2008.07.005 ↗
30. A comprehensive study of externally venting flames – Part I: experimental plume characteristics for through-draft and no-through-draft ventilation conditions and repeatability10.1016/S0379-7112(00)00040-0 ↗
31. Wind effects on smoke motion and temperature of ventilation-controlled fire in a two-vent compartment10.1016/j.buildenv.2009.04.008 ↗
32. Flame height characteristics based on image luminance
33. A threshold selection method from gray-level histogram10.1109/TSMC.1979.4310076 ↗