Suppression effectiveness of water-mist sprays on accelerated wood-crib fires
Source abstract
Abstract
Abstract An experimental analysis was conducted to quantify the water-mist discharge characteristics required to suppress wood-crib fires. The overall aim of this research was to investigate the effectiveness of these innovative systems in a canonical fire scenario. To this end, an experimental suppression facility was constructed including commercially available water mist nozzles, thermocouples for measuring the thermal transient in and around the wood cribs and a load cell for measuring the mass loss rate and the final wood crib damage. 510×510×380 mm wood cribs were used as the fuel source in all the experiments. The injection pressure and orifice diameter of the water-mist nozzles were varied in the experiments to modify the applied water flux and the initial spray momentum. These quantities were identified to be the governing parameters for suppression performance. They were characterized for all experiments along with the drop-size and velocity distributions. Critical values were determined for these quantities from first order kinematic and thermal analysis based on spray and fire source characteristics. The experimental results demonstrated critical suppression behavior consistent with this first order analysis.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Combustion and Detonation Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. J.A. Block, A theoretical and experimental study of nonpropagating free-burning fires, in: Proceedings of the 13th International Symposium on Combustion, 1971, pp. 971–978.10.1016/S0082-0784(71)80097-8 ↗
2. A study of the extinguishment of vertical wood slabs in self-sustained burning by water spray application10.1080/00102207608946741 ↗
3. The application of water sprays to the extinguishment of crib fires10.1080/00102207608946742 ↗
4. Full-scale experiments of fire suppression in high-hazard storages: a temperature-based analysis of water–mist systems10.1016/j.applthermaleng.2012.04.011 ↗
5. Fire control and suppression by water–mist systems10.2174/1874396X01004010167 ↗
6. Minimum water requirements for suppression of room fires10.1007/BF02588856 ↗
7. Investigation to improve the effectiveness of water in the suppression of compartment fires
8. Understanding sprinkler performance: modeling of combustion and extinction10.1007/BF02590320 ↗
9. Fire extinguishment time by sprinkler10.3801/IAFSS.FSS.1-1187 ↗
10. Hirst · 1989
11. Scaling the interaction of water sprays and flames10.1016/S0379-7112(02)00012-7 ↗
12. Extinction of gas and liquid pool fires with water sprays10.1016/S0379-7112(02)00085-1 ↗
13. Extinguishment of cooking oil fires by water mist fire suppression systems10.1023/B:FIRE.0000039161.18616.86 ↗
14. Physical scaling of water mist suppression of wood crib fires in enclosures
15. Optimal droplet diameter and relative sprinkler location in fire-sprinkler interaction10.3801/IAFSS.FSS.6-421 ↗
16. Analysis of fire suppression effectiveness using a physically based computer simulation10.3801/IAFSS.FSS.1-1207 ↗
17. Cooling of room fires by sprinkler sprays
18. Characterization of high-pressure water-mist sprays: experimental analysis of droplet size and dispersion10.1016/j.expthermflusci.2010.06.008 ↗
19. P.E. Santangelo, P. Tartarini, B. Pulvirenti, P. Valdiserri, A.W. Marshall, Fire suppression by water-mist sprays: experimental and numerical analysis, in: Proceedings of the 14th International Heat Transfer Conference (IHTC-14), 2010, paper IHTC14-22634, vol. 5, pp. 571–580.10.1115/IHTC14-22634 ↗
20. P.E. Santangelo, P. Tartarini, P. Valdiserri, Experimental parametric analysis of water-mist sprays: an investigation on coalescence and initial dispersion, in: Proceedings of the ASME 2011 International Mechanical Engineering Congress & Exposition (IMECE 2011), 2011, paper IMECE2011-63846, vol. 6, pp. 1167–1174.10.1115/IMECE2011-63846 ↗
21. Experiments and modeling of discharge characteristics in water–mist sprays generated by pressure-swirl atomizers10.1007/s11630-012-0579-5 ↗
22. UL 2167 Water Mist Nozzles for Fire Protection Service, UL, Camas, WA, USA, 2004.
23. A robust bidirectional low-velocity probe for flame and fire application10.1016/0010-2180(76)90062-6 ↗
24. The application of stereoscopic PIV to measure the flow of air into an enclosure containing a fire10.1007/s00348-009-0656-z ↗
25. A comparison of gas velocity measurements in a full-scale enclosure fire10.1016/j.firesaf.2009.03.010 ↗
26. Open Performance Data Table, BETE Fog Nozzle, Inc., 〈http://www.bete.com/products/p.html〉.
27. Burning rate of a pool fire with downward-directed sprays10.1016/S0379-7112(96)00024-0 ↗
28. Experiments and theory in the extinction of a wood crib10.3801/IAFSS.FSS.1-1197 ↗
29. Overview of sprinkler technology research10.3801/IAFSS.FSS.5-93 ↗
30. Fire plume
31. Generation of heat and gaseous, liquid, and solid products in fires
32. Quintiere · 1980 · vol. I
33. Madrzykowski · 1998
34. Cote · 1988
35. The extinction of fire with plain water: a review10.3801/IAFSS.FSS.1-1145 ↗
36. Extinguishment of enclosed gas fires with water spray10.3801/IAFSS.FSS.3-997 ↗
37. Solid fire extinguishment by a water spray10.1016/S0379-7112(98)00036-8 ↗
38. Extinction of fires of small wooden cribs with sprays of water and some solutions
39. The role of water in suppression of fires
40. Fire suppression by water sprays10.1016/S0360-1285(99)00012-X ↗
41. Quintiere · 2008
42. Active fire protection – extinguishment of enclosed gas fires with water sprays
43. M. Stolp, The extinction of small wood crib fires by water, in: Proceedings of the 5th International Fire Protection Seminar, 1976, pp. 127–141.
44. Incropera · 2007
45. Babrauskas · 2003
46. Predicting the burning of wood using an integral model10.1016/S0010-2180(00)00162-0 ↗