journal article·2017-01Open access

The influence of vehicular obstacles on longitudinal ventilation control in tunnel fires

W. Ulises Rojas Alva, Grunde Jomaas, Anne S. Dederichs

Abstract

Abstract The effect of the vehicular blockage in a tunnel under longitudinal ventilation smoke control was systematically studied using a small-scale tunnel (1:30 of a standard tunnel section) with a helium-air mixture as the buoyant plume. The experimental results showed excellent agreement with full-scale data and reference correlations from former studies. When there are vehicular obstacles in the tunnel, the critical velocity decreased as a function of the blockage ratio. Notwithstanding, it was found that the relative size of the vehicular obstacle and the relative location of the fire source can have a reversed effect, inasmuch as the presence vehicular obstacle exerted an influence on the critical and confinement velocities. Moreover, the backlayering distance was evidently affected by the vehicular blockage. A parallel analysis was carried out for the backlayering distance for lower and upper regimes of the dimensionless heat release rate, where the current data was compared against data from other studies. The method and experimental set-up proved their ability to reproduce several phenomena and thus also their capability to supply relevant and valuable information on the effect of the vehicular blockage on tunnel fire dynamics.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Evacuation and Crowd Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Flashback: Kaprun ski train fire. 〈http://news.bbc.co.uk/1/hi/world/europe/3502265.stm〉 (accessed 06.08.14), 2004.
2. Land transport accident investigation bureau (BEA-TT). 〈http://www.bea-tt.equipement.gouv.fr/_affiche_article.php3?Id_article=33〉, (n.d.) (accessed 06.08.14).
3. Lönnermark · 2005
4. Ingason · 2015
5. PIARC Committee on Road Tunnels, Maitrise des incendies et des fumees dans les tunnels routiers - Fire and Smoke control in road tunnels, PIARC Committee on Road Tunnels, 1999
6. Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires10.1016/j.firesaf.2010.07.003 ↗
7. Definition and experimental evaluation of the smoke “confinement velocity” in tunnel fires10.1016/j.firesaf.2005.02.004 ↗
8. Beard · 2012
9. The movement of smoke in horizontal passages against an air flow
10. A.J.M.Heselden, Studies of fire and smoke behaviour relevant to tunnels, in: Proceedings of the Second Int. Symp. Aerodyn. Vent. Veh. Tunnels, Cambridge, 1976.
11. A preliminary note on the movement of smoke in an enclosed shopping mall
12. N.H.Danzinger, W.D.Kennedy, Longitudinal ventilation analysis for the Glenwood Canyon tunnels, in: Proceedings of the Fourrth Int. Symp. Aerodyn. Vent. Veh. Tunnels, BHRA Fluid Engineering, York, U.K, 1982.
13. Y. Oka, G. T, Atkinson, Control of Smoke flow in Tunnel Fires, 25, 1996, pp. 305–32210.1016/0379-7112(96)00007-0 ↗
14. Control of smoke flow in tunnel fires using longitudinal ventilation systems - a study of the critical velocity10.1016/S0379-7112(00)00031-X ↗
15. Simple model for control of fire gases in a ventilated tunnel10.1016/S0379-7112(01)00020-0 ↗
16. Parametrical study of the back flow occurrence in case of a buoyant release into a rectangular channel10.1016/j.expthermflusci.2005.01.002 ↗
17. Experimental simulations of fire-induced smoke control in tunnels using an “air–helium reduced scale model”: principle, limitations, results and future10.1016/j.tust.2007.04.003 ↗
18. Influence of tunnel width on longitudinal smoke control10.1016/j.firesaf.2006.02.007 ↗
19. Theoretical and experimental study of critical velocity for smoke control in a tunnel cross-passage10.1007/s10694-010-0170-0 ↗
20. Ingason · 2011
21. H.Ingason, M.Kumm, D.Nilsson, A.Lönnermark, A.Claesson, Y.Z.Li, et al., The Metro Project, Final Report, Västerås, 2012.
22. Model scale tunnel fire tests with point extraction ventilation10.1177/1042391510394242 ↗
23. Ingason · 2010
24. Model of ventilation flows during large tunnel fires10.1016/j.tust.2012.02.007 ↗
25. J.P. Vantelon, A. Guelzim, D. Quach, D. Kim Son, D. Gabay, D. Dallest, Investigation of Fire-Induced Smoke Movement in Tunnels and Stations: An Application to the Paris Metro, 1991, pp. 907–918.10.3801/IAFSS.FSS.3-907 ↗
26. P.Deberteix, D.Gabay, D.Blay, Experimental study of fire-induced smoke propagation in a tunnel in the presence of longitudinal ventilation, in: Proceeedings of Int. Conference Tunn. Fires Escape from Tunnels, Washington, 2001, pp. 257–265.
27. Effect of blockage ratio on critical velocity in tunnel fires10.1177/0734904112443508 ↗
28. Effect of vehicular blockage on critical ventilation velocity and tunnel fire behavior in longitudinally ventilated tunnels10.1016/j.firesaf.2012.06.013 ↗
29. H.Ingason, A.Lönnermark, Effects of longitudinal ventilation on fire growth and maximum heat release rate, in: S.T.R.I. of Sweden (Ed.), Fourth International Symp. Tunn. Saf. Securpp. 395–406, 2010.
30. F. Tarada, New Perspectives on the Critical Velocity for Smoke Control, in: A. Lönnermark, H. Ingason (Eds.), Fourth Int. Symp. Tunn. Saf. Secur., SP Technical Research Institute of Sweden, Frankfurt am Main, Germany, 2010: pp. 419–426.
31. A. Milford, K. Calder, P. Senez, A. Coles, Computational study of tunnel ventilation effects on fire development in rapid transit vehicles, in: A. Lönnermark, H. Ingason (Eds.), Proceedings of the Sixth Int. Symp. Tunn. Saf. Secur., SP Technical Research Institute of Sweden, Marseille, France, 2014, pp. 381–390.
32. Megret · 1999
33. A model to evaluate tunnel fire characteristics10.1016/S0379-7112(00)00010-2 ↗
34. O.Megret, O.Vauquelin, P.Chasse, A reduced scale tunnel for the study of fire-induced smoke control, in: Proceedings of the 3rd International Conference Saf. Road Rail Tunnels., Nice, France, n.d.: pp. 713–723
35. H.Ingason, Model Scale Tunnel Fire Tests Longitudinal ventilation, SP REPORT 2005:49, BORÅS, Sweden, 2005.
36. Lönnermark, Runehamar tunnel fire tests10.1016/j.firesaf.2014.11.015 ↗
37. Scaling laws for a buoyant release used to simulate fire-induced smoke in laboratory experiments10.1016/j.firesaf.2008.11.001 ↗
38. Methodology for simulating tunnel ventilation flows during fires10.1007/s10694-010-0144-2 ↗
39. Reducing the computational requirements for simulating tunnel fires by combining multiscale modelling and multiple processor calculation
40. Massachwsetts Highwav Department, Bechtel, P. Brinckerhoff, Memorial Tunnel Fire Ventilation Test Program, Test Report, Massachusetts, 1995.
41. Studies on buoyancy-driven back-layering flow in tunnel fires10.1016/j.expthermflusci.2008.03.005 ↗