journal article·2015-01

Effect of transverse reinforcement spacing on fire resistance of high strength concrete columns

Szymon Seręga

Publisher page

Abstract

Abstract The confinement effect due to the congested transverse reinforcement is a very important feature for reinforced concrete columns subjected to accidental load conditions. The influence of transverse reinforcement spacings on load bearing capacity of high strength concrete (HSC) columns at ambient temperature has been the subject of many research projects, both experimental and theoretical. However, at high temperature the results of research into this subject are scarce and do not provide unambiguous evidence as to the effect of spacing of transverse reinforcement on fire load capacity and fire resistance. The first part of this paper presents an experimental study of the influence of transverse reinforcement spacing on fire resistance of axially loaded, HSC columns with circular cross-section. The results of full-scale tests indicate that columns with spacing of ties recommended by the code provisions for design of concrete structures could suffer a premature failure as a consequence of inelastic buckling of main reinforcing bars between adjacent ties. The next part of the paper concerns the supplementary numerical analysis of tested columns. The columns were modelled in axisymmetry with embedded reinforcement. The applied material model took into account the influence of transient temperature on mechanical properties of concrete and steel. The effect of cracking, development of transient creep strains and plastic strains for concrete were also included in the analysis. The inelastic buckling of main reinforcement was modelled using average stress–strain relationships for steel in compression. The comparison of numerical simulations and experiments shows reasonable agreement. The assessment of failure modes using the numerical simulation is also presented in the paper. The results of calculations indicate that during the whole heating period high thermal gradients generated tensile stresses in the plane of cross-section of the columns. Due to this fact the confinement effect was not observed for the columns with congested spacing of transverse reinforcement.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. 2004
2. 2002
3. High-Strength Concrete Columns: State of the Art
4. 2011
5. 2004
6. Strength and ductility of tied concrete columns10.1061/JSDEAG.0005416 ↗
7. , Stress–strain behavior of concrete confined by overlapping hoops at low and high strain rates
8. Confinement effectiveness of crossties in RC10.1061/(ASCE)0733-9445(1985)111:10(2105) ↗
9. Observed stress–strain behavior of confined concrete10.1061/(ASCE)0733-9445(1988)114:8(1827) ↗
10. M. Nishiyama, I. Fukushima, F. Watanabe, and H. Muguruma, Axial loading tests on high-strength concrete prisms confined by ordinary and high-strength steel, in: Third International Symposium on the Utilization of High-Strength Concrete, vol. V, Lillehammer, June 1993, pp. 322–329.
11. High-strength concrete columns confined by rectangular ties10.1061/(ASCE)0733-9445(1994)120:3(783) ↗
12. High-strength concrete columns with square sections under concentric compression10.1061/(ASCE)0733-9445(1998)124:12(1438) ↗
13. New approach for modeling confined concrete. I: circular columns10.1061/(ASCE)0733-9445(2001)127:7(743) ↗
14. Cracks in concrete core due to fire or thermal heating shock,
15. 2004
16. 2002
17. Studies on high-strength concrete columns under eccentric compression,
19. J.-C. Dotreppe, R. Ludwig, V.K.R. Kodur, and J.-M. Fransen, High strength concrete columns under fire conditions: experimental tests, numerical simulations and provisions of pren1992-1-2, in: FIB Symposium “Keep concrete Attractive”, Budapest, 2005.
20. Critical factors governing the fire performance of high strength concrete systems,10.1016/j.firesaf.2006.10.006 ↗
21. Kodur · 2000
22. Kodur · 2005
23. Fire tests and calculation methods for circular concrete columns10.1023/A:1021783311892 ↗
24. Effect of silica fume and lateral confinement on fire endurance of high strength concrete columns10.1139/l05-089 ↗
25. Seręga · 2009
26. S. Seręga, A new simplified method for determining fire resistance of reinforced concrete sections, in: Proceedings of 6th International Conference Analytical Models and New Concepts in Concrete and Masonry Structures, 2008, pp. 383–384 and CD.
27. DIANA-Finite Element Analysis. User's Manual.
28. Behaviour of concrete at high temperatures
29. Predicting the fire resistance behaviour of high strength concrete columns10.1016/S0958-9465(03)00089-1 ↗
30. S. Seręga, Numerical assessment of the failure mode of RC columns subjected to fire, in: N. Bićanić, R. Borst, H. Mang, and G. Meschke, (Eds.), Proceedings of EURO-C 2010 International Conference Computational Modelling of Concrete Structures, CRC Press/Balkema, 2010, (10.1201/b10546-97).10.1201/b10546-97 ↗
31. Uniaxial model for concrete under variable temperature and stress10.1061/(ASCE)0733-9399(1993)119:8(1507) ↗
32. Smeared cracking, plasticity, creep and thermal loading-a unified approach10.1016/0045-7825(87)90091-0 ↗
33. Hordijk · 1991
34. Fracture energy of high-performance concrete at high temperatures up to 450°C: the effects of heating temperatures and testing conditions (hot and cold)10.1680/macr.2006.58.5.277 ↗
35. Analysis of concrete structures under thermal loading10.1016/0045-7825(89)90079-0 ↗
36. Gradient enhanced thermo-mechanical damage model for concrete at high temperatures including transient thermal creep10.1002/nag.376 ↗