A transient one-zone computer model for total flooding water mist fire suppression in ventilated enclosures
Source abstract
Abstract
As water mist fire fighting systems become increasingly common, there is a need to transform the accumulated practical experience to quantitative models. As a contribution to this process, this paper proposes a transient one-zone computer model for total flooding water mist fire suppression in ventilated enclosures. The one-zone approach is based on the experimentally observed ability of the water sprays to mix the gas volume of the protected space. From this assumption, the model solves the time evolution of temperature, gas density, gas composition and water mist concentration inside the protected space. The model incorporates a detailed description of the liquid phase (mist droplets) and the evaporation process. The extinguishment of a hydrocarbon flame is predicted based on the adiabatic flame temperature concept. The possibilities and limitations of the model are demonstrated by validation against experimental data from large-scale machinery space fire suppression tests.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Combustion and Detonation Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Mawhinney JR, Richardson JK. Status report on water mist fire suppression systems—1996. NISTIR 6030, National Institute of Standards and Technology, Gaithersburg, MD, 1997. p. 137–44.
2. Liu · Fire Technology · 1999 · 35 · 33610.1023/A:1015453014065 ↗
3. Pepi JS. Advances in the technology of intermediate pressure water mist systems for the protection of flammable liquid hazards. Proceedings of the Halon Options Technical Working Conference, Albuquerque, NM, 1998. p. 417.
4. Back G, Lattimer B, Beyler C, Di Nenno P, Hansen R. Full-scale testing of water mist fire suppression systems for small machinery spaces and spaces with combustible boundaries—vol. 1. USCG Report No CG-D-21-99, US Coast Guard R&D Center, 1082 Shennecossett Road, Groton, CT, 1999.
5. Back G, Beyler C, DiNenno P, Hansen R. Water mist fire protection for very large machinery spaces. USCG Report No CG-D-15-00, US Coast Guard R&D Center, 1082 Shennecossett Road, Groton, CT, 2000.
6. Mawhinney J. Fire Protection Engineering 1999;28.
7. Mawhinney RN, Galea ER, Patel MK. Fire-sprinkler spray interaction modelling using an Euler–Lagrange approach. Proceedings of Interflam ’96, the Seventh International Fire Science and Engineering Conference, 1996. p. 841–45.
8. Wighus R. An empirical model for extinguishment of enclosed fires with water mist. Proceedings of the Halon Options Technical Working Conference, Albuquerque, NM, 1998.
9. Alpert RL, Delichatsios MM. Calculated interaction of water droplet sprays with fire plumes in compartments. NBS-CGR-86-520, National Bureau of Standards, 1986.
10. Jackman LA, Nolan PF, Gardiner AJ, Morgan HP. Proceedings of the First International Conference on Fire Suppression Research. The Swedish Fire Research Board and US Department of Commerce, National Institute of Standards and Technology, 1992. p. 209–27.
11. Pietrzak · 1983
12. Nyankina K, Turan ÖF, He Y, Britton M. One-layer zone modelling of fire suppression: gas cooling and blockage of flame spread by water sprinklers. Proceedings of the Eighth International Interflam Conference, London: Interscience Communications Ltd., 1999. p. 1081–92.
13. Wighus R. Active fire protection—extinguishment of enclosed gas fires with water sprays. SINTEF Report No. STF25 A91028, 1991.10.3801/IAFSS.FSS.3-997 ↗
14. Back G, Beyler CL, DiNenno PJ, Hansen R, Zalosh R. Full scale testing of water mist fire suppression systems in machinery spaces. USCG Report No CG-D-26-98, US Coast Guard R&D Center, 1082 Shennecossett Road, Groton, CT, 1998.
15. Back · Fire Safety Journal · 2000 · 35 · 32710.1016/S0379-7112(00)00038-2 ↗
16. Grant · Progress in Energy Combustion Science · 2000 · 26 · 7910.1016/S0360-1285(99)00012-X ↗
17. Liu · Journal of Fire Protection Engineering · 2000 · 10 · 32
18. Dubay · NFPA Journal · 1999 · 93 · 58
19. Vaari J. Large-scale fire extinguishing tests with water mists at VTT. Proceedings of the Third Fire Suppression and Detection Research Application Symposium, Orlando, FL, 1999.
20. Lefebvre AH. Atomization and Sprays Washington, DC: Hemisphere Publishing Corporation 1989.10.1201/9781482227857 ↗
21. Chow · 1979
22. Hinds · 1982
23. Spalding DB. Fourth International Symposium on Combustion. Baltimore: The Williams & Wilkins Company, 1953. p. 847.10.1016/S0082-0784(53)80110-4 ↗
24. Sparrow · Transactions of the ASME · 1958 · 80 · 879
25. Godsave GAE. Fourth International Symposium on Combustion. Baltimore: The Williams & Wilkins Company, 1953. p. 818.10.1016/S0082-0784(53)80107-4 ↗
26. Law · Progress in Energy Combustion Science · 1984 · 10 · 29510.1016/0360-1285(84)90113-8 ↗
27. Ewing · Fire and Materials · 1984 · 8 · 14810.1002/fam.810080305 ↗
28. Drysdale · 1999
29. Andersson · Journal of Fire Protection Engineering · 1999 · 9 · 3110.1177/104239159800900404 ↗
30. Dlugogorski BZ, Hichens RK, Kennedy EM, Bozzelli JW. Water vapour as an inerting agent. Proceedings of the Halon Options Technical Working Conference, Albuquerque, NM, 1997.
31. Thomas · 1995 · 303
32. Ferziger · 1997 · 127
33. MSC/Circ.668, ANNEX, APPENDIX B Interim test method for fire testing equivalent water-based fire-extinguishing systems for machinery spaces of Category A, International Maritime Organization, London, 30 December 1994; MSC/Circ.728, ANNEX Amendments to the test method for equivalent water-based fire-extinguishing systems for machinery spaces of Category A contained in MSC/Circ.668, ANNEX, APPENDIX B, International Maritime Organization, London, 4 June 1996.
34. Beyler C. In: DiNenno PJ, et al., editors. The SFPE handbook of fire protection. 2nd ed. Massachusetts: NFPA, Quincy, 1995. p. 2–157.