journal article·2007-09

Behaviour and design of beam-to-column connections under fire conditions

N.H. Ramli-Sulong, A.Y. Elghazouli, B.A. Izzuddin

Fire Safety Journal· Volume 42· Issue 6-7
Publisher page

Abstract

In this paper, the main approaches used for developing a component-based connection model are presented and discussed. The model is capable of simulating the behaviour of typical connection configurations in both steel and composite framed structures under monotonic and cyclic loading conditions at ambient as well as elevated temperatures. Validation of the proposed connection model is carried out by comparison against a range of available experimental results, and implementation is undertaken within an advanced finite element program that accounts for material and geometric non-linearities. A series of sensitivity studies are then presented in order to demonstrate the scope of application of the proposed model, and to examine the influence of connection behaviour on the overall structural performance in fire. A number of structural configurations are investigated starting from isolated members and reaching more detailed representations. Several factors are assessed including connection type, boundary conditions and temperature effects. Finally, key parameters and considerations related to connection design are examined.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. O’Connor MA, Martin DM. Behaviour of a multi-storey steel framed building subjected to fire attack. J Constr Steel Res 46(1–3): Paper no. 169.10.1016/S0143-974X(98)00122-9 ↗
2. Analytical assessment of the structural fire response of composite floors10.1016/S0379-7112(01)00039-X ↗
3. A structural analysis of the first Cardington test10.1016/S0143-974X(01)00004-9 ↗
4. Izzuddin BA. Nonlinear dynamic analysis of framed structures. PhD Thesis, Imperial College, University of London; 1991.
5. Ramli Sulong NH. Behaviour of steel connections under fire conditions. PhD Thesis, Imperial College London, University of London; 2005.
6. European Committee for Standardisation, Eurocode 3: Design of steel structures Part 1.8: design of joints. Brussels; 2003.
7. Weynand K, Jaspart JP, Steenhuis M. The stiffness model of revised Annex J of Eurocode 3. Connections in steel structures: behaviour, strength and design, Trento, Italy, 1995. p. 441–52.10.1016/B978-008042821-5/50100-0 ↗
8. Experimental analysis of bolted connections: snug versus preloaded bolts10.1061/(ASCE)0733-9445(1998)124:7(765) ↗
9. The behaviour of high-strength grade 8.8 bolts in fire10.1016/0143-974X(94)00013-8 ↗
10. Spyrou · 2002
11. Al-Jabri · 1999
12. Analyses of the effects of cooling and fire spread on steel-framed buildings10.1016/S0379-7112(96)00027-6 ↗
13. Response of idealised composite beam-slab systems under fire conditions10.1016/S0143-974X(00)00006-7 ↗
14. Jaspart JP, Braham M, Cerfontaine F. Strength of joints subjected to combined action of bending moments and axial forces. EuroSteel ‘99, Prague, 1999. p. 465–468.
15. Behaviour of flush endplate beam-to-column joints under bending and axial force10.12989/scs.2004.4.2.077 ↗
16. Cerfontaine F, Jaspart JP. Analytical study of the interaction between bending and axial force in bolted joints. Eurosteel 2002, Coimbra, 2002. p. 997–1006.
17. A ductility model for steel connections10.1016/S0143-974X(00)00009-2 ↗
18. Kuhlmann U, Davison JB, Kattner M. Structural systems and rotation capacity. In: Proceedings of COST conference on control of the semi-rigid behaviour of civil engineering structural connections, Liege, Belgium, 1998. p. 167–76.