journal article·2009-11

Fire-resistance study of restrained steel columns with partial damage to fire protection

Wei-Yong Wang, Guo-Qiang Li

Fire Safety Journal· Volume 44· Issue 8
Publisher page

Abstract

In order to analyze the behavior of steel columns in fire with partial damage of fire protection, an analytical model is presented based on the differential equation of equilibrium, which may be used to predict the ultimate load bearing capacity of steel columns fixed at two ends and to predict the critical temperature of axially restrained steel columns. The imperfection of initial flexure of steel columns is taken into account in the model. The yielding of the edge fiber at the mid-span of a column subjected to elevated temperature is taken as the failure criteria for the fire resistance of the column. A numerical application is carried out to demonstrate the effect of the damage of fire protection on the ultimate load bearing capacity and axial force increase of axially restrained steel column in fire. Comparing with FEM, the model proposed in the paper has been validated and good agreement has been found.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Response to Dynamic Loads · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (13)

Show source-provided references
1. An investigation of the reduction in fire resistance of steel columns caused by loss of spray—applied fire protection10.1177/1042391502012001865 ↗
2. K. Yu, G.V. Hadjisophocleous, H.A. Khoo, The effect of partial fire protection loss on the fire resistance reduction of steel beams, in: Fourth International Workshop Structures in Fire, Aveiro. Portugal. May 2006, pp. 63–74.
3. J.A. Milke, N. Ryder, S. Wolin, Analyses of the impact of loss of spray-applied fire protection on the fire resistance of steel columns, in: Proceedings of the Seventh International Symposium on Fire Safety Science, International Association for Fire Safety Science, 2003, pp. 1025–1036.10.3801/IAFSS.FSS.7-1025 ↗
4. M. Fontana, M. Knobloch, Fire resistance of steel columns with partial loss of fire protection, in: Proceedings of the IABSE Symposium Shanghai 2004, Metropolitan Habitats and Infrastructure, IABSE Report vol. 88, Shanghai, China, ISBN 3-85748-110-2, 2004, pp. 352f.10.2749/222137804796302202 ↗
5. M. Knobloch, E. Raveglia, M. Fontana, Partial loss of fire protection and structural collapse of high-rise buildings, in: International Congress Fire Safety in Tall Buildings, University of Cantabria, Santander, Spain, October 2006, pp. 41–57.
6. S. Pessiki, K. Kwon, B.J. Lee, Fire load behavior of steel building columns with damaged spray—applied fire resistive material, in: Fourth International Workshop Structures in Fire, Aveiro, Portugal, May 2006, pp. 235–245.
7. A simple approach for modelling fire-resistance of steel columns with locally damaged fire retardant coating10.1016/j.engstruct.2008.11.004 ↗
8. Effect of axial restraint on fire resistance performance of steel column
9. Experimental research on the critical temperature of compressed steel elements with restrained thermal elongation10.1016/S0379-7112(00)00018-7 ↗
10. Fire resistance of steel columns with elastically restrained axial elongation and bending10.1016/S0143-974X(99)00033-4 ↗
11. Analytical fire resistance of axially restrained steel columns10.1061/(ASCE)0733-9445(2003)129:11(1531) ↗
12. Fire tests of non-sway loaded and rotationally restrained steel column assemblies10.1016/S0143-974X(02)00035-4 ↗
13. Chinese Technical Code on Fire Safety of Steel Building Structures, (CECS200-2006), Beijing, 2006 (in Chinese).