Plume flow in high rack storages
Source abstract
Abstract
A theoretical and experimental study of rack storage fires is presented. Free-burn tests with multiple-wall corrugated paper cartons were carried out in reduced scale and in large scale. The in-rack flame height, excess centreline gas temperature and gas velocity were plotted using axi-symmetric quasi-steady state power law correlations. The correlations include overall convective heat release rate, vertical flue width, height above the floor and height of virtual origin. The correlations obtained can be used to predict activation times of in-rack sprinklers and they can be incorporated into engineering models designed to predict flame spread and fire growth in storage geometries. The study shows that it is possible to reproduce flow conditions and flame heights in different scales which is of practical importance since all large scale testing with high rack storages is very expensive.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire Detection and Safety Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Engineering relations for fire plumes10.1016/0379-7112(84)90005-5 ↗
2. Alpert R. Turbulent ceiling—jet induced by large scale fires, C3. Combustion Science and Technology II, 1975, p. 197–213.10.1080/00102207508946699 ↗
3. Fire plumes and ceiling jets10.1016/0379-7112(86)90052-4 ↗
4. Morton BR, Taylor G, Turner JS. Turbulent gravitational convection from maintained and instantaneous sources. Proc R Soc (London) A234, 1956, p. 1–23.10.1098/rspa.1956.0011 ↗
5. Heskestad G, Delichatsios MA. The initial convective flow in fire. 17th International Symposium on Combustion, Combustion Institute, Pittsburgh, 1978, p. 1113–23.10.1016/S0082-0784(79)80106-X ↗
6. Thomas PH. Some comments on fire spread in high racked storage of goods. Department of Fire Safety Engineering, Lund University, 1993.
7. Yu H-Z, Kung H-C. Strong buoyant plumes of growing rack storage fires. The Twentieth Symposium (International) on Combustion, The Combustion Institute, Pittsburgh, 1984, p. 1567.
8. Kung H-C, Yu H-Z, Spaulding RD. Ceiling flows of growing rack storage fires. Twenty-First Symposium (International) on Combustion, The Combustion Institute, 1986, p. 121–8.10.1016/S0082-0784(88)80238-8 ↗
9. Yu H-Z, Stavrianidis P. The transient ceiling flows of growing rack storage fires. Fire Safety Science—Proceedings of the Third International Symposium, p. 281–90.10.3801/IAFSS.FSS.3-281 ↗
10. Field P. Effective sprinkler protection for high racked storage. Fire Surveyor, October 1985, p. 9–24.
11. Fire Tests on High-Piled Storage Protected by Automatic Sprinklers, Comite Europeen des Assurances, TE 30153, April 1990.
12. Person H. Evaluation of the RDD-measuring Technique. RDD-tests of the CEA and FMRC standard plastic commodities. Swedish National Testing and Research Institute, SP-Report 1991:04.
13. Saito K, Quintiere JG, Williams FA. Upward turbulent flame spread. Proceedings of the First International Symposium on Fire Safety Science, Gaithersburg, MD, 1985, p. 75–86.10.3801/IAFSS.FSS.1-75 ↗
14. Hasemi Y, Yoshida M, Nohara A, Nakabayashi T, Unsteady-state upward flame spreading velocity along vertical combustible solid and influence of external radiation on the flame spread. Fire Safety Science—Proceedings of the Third International Symposium, p. 197–206.10.3801/IAFSS.FSS.3-197 ↗
15. Delichatsios MM, Mathews MK, Delichatsios MA. An upward fire spread and growth simulation. Fire Safety Science—Proceedings of the Third International Symposium, p. 207–16.10.3801/IAFSS.FSS.3-207 ↗
16. NFPA 231C, vol. 6. National Fire Protection Association, Batterymarch Park, Quincy.
17. The development of the ESFR sprinkler system10.1016/0379-7112(88)90045-8 ↗
18. Heskestad G. Flame heights of fuel arrays with combustion in depth. The Fifth International Symposium on Fire Safety Science, Melbourne, Australia, 1997, p. 427–38.10.3801/IAFSS.FSS.5-427 ↗
19. Numerical modelling of early flame spread in warehouse fires10.1016/0379-7112(95)00022-L ↗
20. Heat transfer from flames between vertical parallel walls10.1016/0379-7112(94)00033-C ↗
21. A mathematical model for calculating heat release rate in the room corner test10.1016/0379-7112(93)90032-L ↗
22. Wall flame heights with external radiation10.1007/BF01038446 ↗
23. ISO 5660, Fire Tests-Reaction to Fire-Rate of Heat Release from Building Products. International Standards Organisation, Geneva, Switzerland, 1991.
24. Hamer A, Beyler C. Modeling the activation of dry pipe sprinklers in high rack storage. Proceedings International Conference on Fire Research and Engineering, 10–15 September, Orlando, Florida, 1995, p. 65–70.
25. Yan Z, Holmstedt G. CFD simulation of upward spread over fuel surface. The Fifth International Symposium on Fire Safety Science, Melbourne, Australia, 1997.10.3801/IAFSS.FSS.5-345 ↗
26. Ingason H. In-rack fire plumes. The Fifth International Symposium on Fire Safety Science, Melbourne, Australia, 1997.10.3801/IAFSS.FSS.5-333 ↗
27. A study of natural convection above a line fire10.1017/S0022112061000573 ↗
28. Morton BR. Modeling fire plumes. Tenth Symposium (Int) on Combustion, The Combustion Institute, 1965, p. 973–982.10.1016/S0082-0784(65)80240-5 ↗
29. Gravitational convection from a Boundary Source10.1111/j.2153-3490.1952.tb01005.x ↗
30. Forced plumes10.1017/S002211205900012X ↗
31. Babrauskas · 1992
32. Dahlberg M. The SP industry calorimeter, for rate of heat release rate measurements up to 10MW. SP Report 1992:43, The Swedish National Testing and Research Institute (SP), Borås, Sweden.
33. Dahlberg M. Error analysis for heat release rate measurement with the SP industry calorimeter. SP Report 1994:29, The Swedish National Testing and Research Institute (SP), Borås, Sweden.
34. Heskestad G. A fire products collector for calorimetry into the MW Range. Report FMRC J.I. OC2E1.RA, Factory Mutual Research Corporation, Norwood.
35. A robust bi-directional low-velocity probe for flame and fire application10.1016/0010-2180(76)90062-6 ↗
36. Physical modeling of fire
37. Heskestad G. Modeling of enclosure fires. 14th International Symposium on Combustion, The Combustion Institute, Pittsburgh, PA, USA, 1973, p. 1021–30.10.1016/S0082-0784(73)80092-X ↗
38. Orloff L, de Ris, J. Froude modeling of pool fires. 19th International Symposium on Combustion, The Combustion Institute, Pittsburgh, PA, USA, 1982, p. 885–95.10.1016/S0082-0784(82)80264-6 ↗
39. Heskestad G. Peak gas velocities and flame heights of buoyancy-controlled turbulent diffusion flames. Eighteenth Symposium (International) on Combustion, The Combustion Institute, 1981, p. 951–60.10.1016/S0082-0784(81)80099-9 ↗
40. Kung H-C, Stavrianidis P. Buoyant plumes of large-scale pool fires. Nineteenth Symposium (International) on Combustion, The Combustion Institute, Pittsburgh, PA, USA, 1982, p. 905–12.10.1016/S0082-0784(82)80266-X ↗
41. Virtual origins of fire plumes10.1016/0379-7112(83)90003-6 ↗
42. Luminous heights of turbulent diffusion flames10.1016/0379-7112(83)90002-4 ↗
43. Heskestad G. Fire plume air entrainment according to two competing assumptions. 21st Symposium (Int) on Combustion/The combustion Institute, 1986, p. 111–20.10.1016/S0082-0784(88)80237-6 ↗
44. Modelling of a two-dimensional rack storage fire10.1016/S0379-7112(97)00024-6 ↗
45. Flame heat transfer in storage geometries10.1016/S0379-7112(97)00062-3 ↗