journal article·2021-03

PV modules on buildings – Outlines of PV roof samples fire rating assessment

Piergiacomo Cancelliere, Giovanni Manzini, Giombattista Traina, Marco Gabriele Cavriani

Fire Safety Journal· Volume 120
Publisher page

Abstract

Abstract The photovoltaic (PV) systems fire risk has grown up reaching a size that is no more negligible. PV fire events have happened mostly on systems installed on residential and industrial buildings and they have set in motion a process mainly aimed at developing product and installation regulations focused on the minimization of that risk. Such a process is growing up with the participation of different actors (authorities having jurisdiction, standardization bodies, PV modules manufacturers, installers, etc.). In this regard, in Italy a first result has been achieved by some new regulations issued by the Italian National Fire Rescue and Service – CNVVF – of the Ministry of Interior focusing on PV modules and roofs coupling, which contain procedures to categorize when a PV installation could be considered safe. To this end, such measures contain reminders to some national reaction to fire technical standards which, however, were developed in the past for products other than PV modules (e.g. wall panels, etc.). The research activity summarized in this paper was carried out in the last years and it was focused essentially on: analysis of Italian and European legal regulations and technical standards about the PV fire risk and identification of their shortcomings; development of new test protocols focused on PV roofs fire rating (based on some of the existing construction products harmonized standards). In particular, the test protocols are using PV roof samples with both PV modules and roof specimens.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Wind and Air Flow Studies · Infrastructure Resilience and Vulnerability Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (11)

Show source-provided references
1. AA.VV. · 2015
2. AA.VV. · 2016
3. Ministero dell'Interno, Dipartimento dei vigili del fuoco, del Soccorso pubblico e della Difesa civile – Direzione centrale per la prevenzione e la sicurezza tecnica, Contenuti della “Guida per installazione impianti FV – Ed.
4. Kreutzmann · 2013
5. Fire behaviour and performance of photovoltaic module backsheets10.1007/s10694-014-0449-7 ↗
6. Rosenthal · 2010
7. Backstrom · 2012
8. Backstrom · 2012
9. Manzini · 2015
10. The fire risk in photovoltaic installations - test protocols for fire behavior of PV modules
11. Regulation (EU) No 305/2011 of the European parliament and of the council. Laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC