Fire spread in a large compartment with exposed cross-laminated timber and open ventilation conditions: #FRIC-02 - Exposed wall and ceiling
Source abstract
Abstract
Cross-laminated timber (CLT) is becoming increasingly popular due to its many advantages. However, it has been shown that exposed CLT can have a significant effect on fire dynamics and spread rates. Further studies are therefore needed to better understand the impact of CLT to fire safety. Two large-scale CLT compartment fire experiments (95 m2) representing a modern office building have been performed, #FRIC-01 and #FRIC-02. This paper presents the second experiment, #FRIC-02, with exposed CLT on the back wall and the ceiling. The fire developed fast and spread across the room in less than 3.5 min from ignition of the wood crib on the floor and in 1.5 min after the ignition of the ceiling. Large external flames were observed, despite the compartment being well-ventilated. The 5-layer CLT, which comprised a 40 mm thick exposed outer layer and was face-bonded using a common European polyurethane adhesive, exhibited glue-line integrity failure and led to a second flashover after a significant period of decay. Subsequent layers of 20 mm also delaminated before the fire was manually extinguished after 3 h. Compared to #FRIC-01, the fire spread rate was faster, and temperatures, charring rates, heat release rates and external flames were higher.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Flame retardant materials and properties · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Review of large-scale fire tests on cross-laminated timber10.1177/07349041211034460 ↗
2. Review of large-scale CLT compartment fire tests10.1016/j.conbuildmat.2021.126099 ↗
3. Review of fire experiments in mass timber compartments: current understanding, limitations, and research gaps10.1002/fam.3121 ↗
4. Fire dynamics inside a large and open-plan compartment with exposed timber ceiling and columns: CodeRed #0110.1002/fam.3049 ↗
5. Impact of ventilation on the fire dynamics of an open‐plan compartment with exposed timber ceiling and columns: CodeRed #0210.1002/fam.3082 ↗
6. 2002
7. Fire experiment inside a very large and open-plan compartment: x-ONE10.1007/s10694-021-01162-6 ↗
8. Fire experiments inside a very large and open-plan compartment: x-TWO
9. Fire spread in a large compartment with exposed cross-laminated timber and open ventilation conditions: #FRIC-01 - exposed ceiling
10. Large scale fire test: the development of a travelling fire in open ventilation conditions and its influence on the surrounding steel structure10.1016/j.firesaf.2022.103575 ↗
11. The Malveira fire test: full-scale demonstration of fire modes in open-plan compartments10.1016/j.firesaf.2019.102827 ↗
12. Effects of exposed cross laminated timber on compartment fire dynamics10.1016/j.firesaf.2017.03.074 ↗
13. Experimental study of combustible and non-combustible construction in a natural fire10.1007/s10694-014-0407-4 ↗
14. Su · 2018
15. Brandon · 2021 · 40
16. Medina Hevia · 2014
17. "Improved fire performance of cross-laminated timber," presented at the World Conference on Timber Engineering
18. Large-scale enclosure fire experiments adopting CLT slabs with different types of polyurethane adhesives: genesis and preliminary findings10.3390/fire5020039 ↗
19. Description of small and large-scale cross laminated timber fire tests10.1016/j.firesaf.2017.03.024 ↗
20. Critical heat flux and mass loss rate for extinction of flaming combustion of timber10.1016/j.firesaf.2017.03.008 ↗
21. Self-extinguishment of cross-laminated timber10.1016/j.firesaf.2019.01.008 ↗
22. 2004
23. 2004
24. Wickström · 2016
25. A robust bidirectional low-velocity probe for flame and fire application10.1016/0010-2180(76)90062-6 ↗
26. Comparison of heat of combustion and calorific value of the cones and wood of selected forest trees species
27. 2000
28. Visual fire power: an algorithm for measuring heat release rate of visible flames in camera footage, with applications in facade fire experiments10.1007/s10694-022-01341-z ↗
29. Reconstruction of the fires and thermal environment in World Trade Center buildings 1, 2, and 710.1007/s10694-012-0288-3 ↗
30. Nelson · 1989
31. Natural fires in large scale compartments
32. Fire performance of wood (Pinus radiata) treated with fire retardants and a wood preservative10.1002/fam.973 ↗
33. Effect of oxygen on the burning rate of wood10.1016/j.combustflame.2021.111591 ↗
34. Structural hazards of smouldering fires in timber buildings10.1016/j.firesaf.2023.103861 ↗
35. Flame extinction and burning behaviour of timber under varied oxygen concentrations10.1016/j.firesaf.2020.103087 ↗
36. Influence of excess fuel from timber lined compartments10.1016/j.conbuildmat.2019.117355 ↗
37. External fire plumes from mass timber compartment fires—comparison to test methods for regulatory compliance of façades10.1002/fam.3129 ↗
38. A Review of factors affecting the burning behaviour of wood for application to tall timber construction10.1007/s10694-018-0787-y ↗
39. Burning dynamics and in-depth flame spread of wood cribs in large compartment fires10.1016/j.combustflame.2021.01.031 ↗