journal article·2017-07

Energy distribution analysis in full-scale open floor plan enclosure fires

Cristian Maluk, Benjamin Linnan, Andy Wong, Juan P. Hidalgo, Jose L. Torero, Cecilia Abecassis-Empis, Adam Cowlard

Publisher page

Abstract

Within a fast evolving built environment, understanding fire behaviour and the thermal exposure upon structural elements and systems is key for the continued provision of fire safe designs and solutions. Concepts of fire behaviour derived from research in enclosure fires has traditionally had a significant impact in general building design. At present, open floor plan enclosures are increasingly common – building design has drastically drifted away from traditional compartmentalisation. Nevertheless, the understanding of fire behaviour in open floor plan enclosures has not developed concurrently. The compartment fire framework, first conceived for under-ventilated fires in cubic compartments, has remained as standard practice. Although energy conservation within the enclosure was the basis for the current compartment fire framework that defines under-ventilated enclosure fires, little effort has been carried towards understanding the distribution of energy in design frameworks conceived for open floor plan enclosure fires. The work presented herein describes an analysis of the energy distribution established within an experimental full-scale open floor plan enclosure subjected to different fire modes and ventilation conditions. The results aim to enable the designer to estimate the fraction of the total energy released during a fire noteworthy to structural performance.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on concrete materials · Combustion and Detonation Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Revisiting the compartment fire10.3801/IAFSS.FSS.11-28 ↗
2. A contemporary review of large-scale non-standard structural fire testing10.1186/2193-0414-2-1 ↗
3. Tests of the severity of building fires
4. K. Fujita, Characteristics of fire inside a non-combustible room and prevention of fire damage, Report 2(2), Japanese Ministry of Construction, BuildingResearch Institute, 1958, Tokyo, Japan.
5. K. Kawagoe. Fire Behaviour in Rooms, Report 27, Japanese Ministry of Construction, BuildingResearch Institute, 1958, Tokyo, Japan.
6. K. Kawagoeand T. Sekine. Estimation of Fire Temperature-time Curve in Rooms, Report 11, Japanese Ministry of Construction, BuildingResearch Institute, 1963, Tokyo, Japan.
7. P.H. Thomas, A.J. Heselden, and M. Law. Fully Developed Compartment Fires – Two Kinds of Behaviour, Fire Research, Technical Paper No. 18, H.M. Stationery Office, 1967, London, UK.
8. A new look at compartment fires10.1007/BF02590544 ↗
9. Drysdale · 2011
10. Majdalani · 2014
11. An experimental study of full-scale open floor plan enclosure fires10.1016/j.firesaf.2017.02.002 ↗
12. A thin skin calorimeter (TSC) for quantifying irradiation during large-scale fire testing10.1016/j.ijthermalsci.2016.10.013 ↗
13. Directive 2010/31/EU of the european parliament and the council of19 may 2010 on the energy performance of buildings
14. B. Anderson, Conventions for U–value calculations, BRE Scotland, 2006.
15. BS EN ISO, 6946. Building components and building elements – Thermal resistance and thermal transmittance – Calculation method, British Standards Institution, 2007.
16. A robust bidirectional low-velocity probe for flame and fire applications10.1016/0010-2180(76)90062-6 ↗
17. K.D. Steckler, J.G. Quintiere JG, W.J. Rinkinen, Flow Induced by Fire in a Compartment, National Bureau of Standards, NBSIR82-2520, Washington DC, USA, 1984.
18. Effects of thermal radiation on the Fluid dynamics of compartment fires10.3801/IAFSS.FSS.3-345 ↗
19. Linnan · 2016
20. Incropera · 2002