A simplified approach for predicting temperatures in insulated RC members exposed to standard fire
Source abstract
Abstract
Fire resistance of concrete structural members can be enhanced through the application of external fire insulation on the surfaces of concrete member. For evaluating fire resistance of such insulated RC members, temperatures in concrete and steel reinforcement are to be known. This paper develops a simplified approach for predicting cross-sectional temperatures in an insulated RC structural member exposed to standard fire. The approach is derived by replacing the insulation layer into an equivalent concrete thickness layer and then undertaking statistical regression analysis on temperature data of modified concrete section. The effect of critical parameters, including geometry of concrete member and insulation, thermal properties of concrete and fire insulation, and duration of fire exposure is accounted for in temperature equations. The validity of the approach is established by comparing predictions from the proposed equation with data generated from fire tests and finite element analysis. These comparisons show the proposed equation gives reasonable prediction of temperatures, within a range of ±10%, in insulated concrete members. The applicability of the proposed approach in design situations is illustrated though a numerical example. The simplicity of the proposed method makes it attractive for use in design situations and for incorporation in design manuals.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Concrete Properties and Behavior
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Fire tests on concrete beams strengthened with fibre composite laminates
2. Fire endurance of fiber-reinforced polymer strengthened concrete T-Beams
3. The experimental behavior of FRP-strengthened RC beams subjected to design fire exposure10.1016/j.engstruct.2011.03.010 ↗
4. ACI216 · 2007
5. Eurocode2 · 2004
6. A simplified approach for predicting temperature in reinforced concrete members exposed to standard fire10.1016/j.firesaf.2012.12.004 ↗
7. Wickstrom · 1986 · 186
8. Hertz · 1981
9. FRP retrofitted concrete under fire conditions
10. Experimental investigation on fire endurance of insulated concrete beams strengthened with near surface mounted FRP bar reinforcement10.1016/j.compositesb.2011.11.061 ↗
11. Equivalent concrete layer thickness of a fire protection insulation layer10.1016/S0379-7112(96)00023-9 ↗
12. A simplified approach for predicting temperatures in fire exposed steel members10.1016/j.firesaf.2012.10.018 ↗
13. Rational approach for evaluating fire resistance of FRP-strengthened concrete beams10.1061/(ASCE)CC.1943-5614.0000697 ↗
14. Purkiss · 2007
15. Dwaikat · 2009
16. Bisby · 2003
17. Fire insulation schemes for FRP-strengthened concrete slabs10.1016/j.compositesa.2005.05.028 ↗
18. Williams · 2004
19. Fire behavior of concrete T-beams strengthened with near-surface mounted FRP reinforcement10.1016/j.engstruct.2014.09.003 ↗
20. Performance in fire of FRP-strengthened and insulated reinforced concrete columns10.1016/j.firesaf.2012.08.006 ↗
21. Experimental evaluation of the fire behaviour of insulated fibre-reinforced-polymer-strengthened reinforced concrete columns10.1016/j.firesaf.2006.05.004 ↗
22. Numerical model for tracing the response of FRP-strengthened RC beams exposed to fire10.1061/(ASCE)CC.1943-5614.0000129 ↗
23. Modeling of insulated CFRP-strengthened reinforced concrete T-beam exposed to fire10.1016/j.engstruct.2009.08.008 ↗
24. Lie · 1992
25. Thermal response of graphite epoxy composite subjected to rapid heating10.1177/002199838101500503 ↗