Characterization of an electro-thermal micro gripper and tip sharpening using FIB technique
Source abstract
Abstract
A micromachined electro-thermal gripper, first introduced by Ivanova et al. (Microelectron Eng 83:1393–1395, 2006), represents a promising candidate for the manipulation and handling of micro or even nano-scaled objects. To further optimize the performance of the device, a detailed electrical and mechanical characterization is needed. Due to the so-called duo-action gripper approach (i.e., a separate actuator for closing and opening action) these investigations focused on the maximum (minimum) opening width being 11.5 μm (3.3 μm), while in rest position a value of 4 μm is feasible. The maximum, electrical input power is limited to 80 mW/actuator element, resulting in a current density of up to 1.27 MA cm−2 in the corresponding metal layers. When applying, however, larger current densities the probability of device failure increases substantially as in combination with an enhanced temperature of about 200°C electromigration effects occur in the metallization. Furthermore, the cut-off frequency and parasitic effects during actuation such as the z-deflection and the increase in length of each arm both showing values of up to 3 μm have been investigated as a function of operation parameters. Finally, the tips of the gripper were sharpened using Focused Ion Beam technique to a radius of less than 1 μm for gripping operations in space-restricted environments or for the manipulation or handling of sub-μm scaled objects.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Force Microscopy Techniques and Applications · Advanced MEMS and NEMS Technologies · Advanced Surface Polishing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Arai F, Andou D, Fukuda T (1996) Adhesion forces reduction for micro manipulation based on micro physics. IEEE 0-7803-2985-6/96:354–35910.1109/MEMSYS.1996.494007 ↗
2. Beyeler F, Neild A, Oberti S, Bell DJ (2007) Monolithically fabricated microgipper with integrated force sensor for manipulating microobjects and biological cells aligned in an ultrasonic field. J Microelectromech Syst 16(1):7–1510.1109/JMEMS.2006.885853 ↗
3. Black JR (1969) Electromigration—a brief survey and some recent results. IEEE Trans Electron Devices ED-16/4:338–34710.1109/T-ED.1969.16754 ↗
4. Colinjivadi KS, Lee J-B, Draper R (2008) Viable cell handling with high aspect ratio polymer chopstick gripper mounted on a nano precision manipulator. Microsyst Technol. doi: 10.1007/s00542-008-0580-910.1007/s00542-008-0580-9 ↗
5. Cvetanovic Al, Cvetanovic An, Deutschinger A, Giouroudi I, Brenner W (2010) Design of a novel visual and control system for the prevention of the collision during the micro handling in a SEM chamber. Microelectron Eng 87/2:139–143. doi: 10.1016/j.mee.2009.06.03110.1016/j.mee.2009.06.031 ↗
6. Ivanova K, Ivanov T, Badar A, Volland B, Rangelow IW, Andrijasevic D, Sümecz F, Fischer S, Spitzbart M, Brenner W, Kostic I (2006) Thermally driven micro gripper as a tool for micro assembly. Microelectron Eng 83:1393–139510.1016/j.mee.2006.01.072 ↗
7. Kim D-H, Lee MG, Kim B, Sun Y (2005) A superelastic alloy microgripper with embedded electromagnetic actuators and piezoelectric force sensors: a numerical and experimental study. Smart Mater Struct 14:1265–127210.1088/0964-1726/14/6/019 ↗
8. Kim Y-R, Chen P, Aziz MJ, Branton D (2006) Focused ion beam induced deflections of freestanding thin films. J Appl Phys 100(10):104322 (1–9). doi: 10.1063/1.236390010.1063/1.2363900 ↗
9. Lee C-Y, Wu G-W, Hsieh W-J (2008) Fabrication of micro sensors on a flexible substrate. Sens Actuators A 147:173–176. doi: 10.1016/j.sna.2008.05.00410.1016/j.sna.2008.05.004 ↗
10. Lienig J, Jerke G (2002) Elektromigration—Teil 1: Ursachen und Beeinflussungsmöglichkeiten. F&M Elektronik 110:36–39
11. Miyazaki HT, Tomizawa Y, Koyano K, Sato T (2000) Adhesion force measurement system for micro-objects in a scanning electron microscope. Rev Sci Instrum 71(8):3123–313110.1063/1.1305812 ↗
12. Nah SK, Zhong ZW (2007) A microgripper using piezoelectric actuation for micro-object manipulation. Sens Actuators A 133:218–224. doi: 10.1016/j.sna.2006.03.01410.1016/j.sna.2006.03.014 ↗
13. Perez R, Chaillet N, Domanski K, Janus P (2006) Fabrication, modeling and integration of a silicon technology force sensor in a piezoelectric micro-manipulator. Sens Actuators A 128:367–375. doi: 10.1016/j.sna.2006.01.04210.1016/j.sna.2006.01.042 ↗
14. Solano B, Wood D (2007) Design and testing of a polymeric microgripper for cell manipulation. Microelectron Eng 84:1219–1222. doi: 10.1016/j.mee.2007.01.15310.1016/j.mee.2007.01.153 ↗
15. Stahlmecke B, Dumpich G (2007) Resistance behaviour and morphological changes during electromigration in gold wires. J Phys Condens Matter 19:1–11. doi: 10.1088/0953-8984/19/4/04621010.1088/0953-8984/19/4/046210 ↗
16. Stavrov V (2010) Low voltage thermo-mechanically driven monolithic microgripper with piezoresistive feedback. IFIP AICT 315:207–214
17. Van Dillen T, De Dood MJA, Roorda S, Vredenberg AM (2004) Ion beam-induced anisotropic plastic deformation of silicon microstructures. Appl Phys Lett 84/18:3591–3593. doi: 10.1063/1.173748010.1063/1.1737480 ↗
18. Voicu R, Esinenco D, Müller R, Eftime L, Tibeica C (2007) Method for overcoming the unwanted displacements of an electro-thermally actuated microgripper. 4M network of excellence. http://www.4m-net.org/KnowledgeBase/papers/199 . Accessed 30 June 2008
19. Volland BE, Ivanova K, Ivanov T, Guliyev E et al (2007) Duo-action electro thermal micro gripper. Microelectron Eng 84:1329–133210.1016/j.mee.2007.01.177 ↗
20. Wierzbicki R, Houston K, Heerlein H, Barth W et al (2006) Design and fabrication of an electrostatically driven microgripper for blood vessel manipulation. Microelectron Eng 83:1651–1654. doi: 10.1016/j.mee.2006.01.11010.1016/j.mee.2006.01.110 ↗
21. Zeman MJF, Bordatchev EV, Knopf GK (2006) Design, kinematic modeling and performance testing of an electro-thermally driven microgripper for micromanipulation applications. J Micromech Microeng 16:1540–1549. doi: 10.1088/0960-1317/168/01410.1088/0960-1317/16/8/014 ↗
22. Zhong ZW, Chan SY (2007) Investigation of a gripping device actuated by SMA wire. Sens Actuators A 136:335–340. doi: 10.1016/j.sna.2006.11.00710.1016/j.sna.2006.11.007 ↗