Smoldering ignition and transition to flaming in wooden mulch beds exposed to firebrands under wind

Shaorun Lin, Chengze Li, Mackenzie Conkling, Xinyan Huang, Stephen L. Quarles, Michael J. Gollner

Fire Safety Journal· Volume 148

Abstract

Spotting ignition by firebrands is a significant fire spread pathway at the wildland-urban interface (WUI), where mulch products are commonly used as landscaping materials. Mulch is typically organic in nature, thus it may be easily ignited into a smoldering mode by firebrands and subsequently transition to flaming, leading to direct flame contact and radiant heat exposure to siding materials of adjacent structures. This work quantified the thresholds of smoldering ignition of four common types of commercially available mulch (black mulch (BM), forest floor (FF), redwood (RW), and fir bark (FB)) exposed to heating by smoldering firebrand piles, and their propensity for smoldering-to-flaming transition under external winds (up to 1.4 m/s). We found that there was a minimum mass of firebrand pile to achieve smoldering ignition of mulch (e.g., ∼0.1 g for FF). Beyond this minimum mass, the required wind speed to trigger smoldering ignition generally decreased as the mass of the firebrand pile increased, agreeing well with theoretical analysis. After smoldering ignition, smoldering-to-flaming transition could be observed when the wind speed exceeded a critical value (e.g., ∼1 m/s for FF), which was not affected by the initial spotting process. To achieve smoldering-to-flaming transition, the glowing mulch had to reach a critical temperature of around 850 °C. Mulch samples with larger particle sizes were more likely to smolder and transition to flaming, due to increased oxygen supply through larger inter-particle pores and channels and better firebrand accumulation due to a more crevice-like geometry on the fuel surface. This work advances the fundamental understanding of the ignition and burning behavior of landscaping mulches, and thus contributes to the prevention of extreme WUI fire events.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fire effects on ecosystems · Fire dynamics and safety research · Plant responses to water stress

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Role of firebrand combustion in large outdoor fire spread10.1016/j.pecs.2019.100801 ↗
2. A review of firebrand studies on generation and transport10.1016/j.firesaf.2022.103674 ↗
3. Wildland fire spot ignition by sparks and firebrands10.1016/j.firesaf.2017.04.040 ↗
4. Role of firebrand combustion in large outdoor fire spread10.1016/j.pecs.2019.100801 ↗
5. The initiation of smoldering Peat fire by a glowing firebrand10.1071/WF23116 ↗
6. A review of pathways for building fire spread in the wildland urban interface Part II: Response of components and systems and mitigation strategies in the United States10.1007/s10694-016-0601-7 ↗
7. Review of pathways for building fire spread in the wildland urban interface Part I: exposure conditions10.1007/s10694-016-0589-z ↗
8. 2020
9. Maranghides · 2021
10. Orgstad · 2011 · 1
11. The ease ofignition of 13 landscape mulches
12. Full-scale experimental investigation to quantify building component ignition vulnerability from mulch beds attacked by firebrand showers10.1007/s10694-015-0537-3 ↗
13. Review of pathways for building fire spread in the wildland urban interface Part I: exposure conditions10.1007/s10694-016-0589-z ↗
14. Effects of wind speed and angle on fire spread along privacy fences
15. Thermal characterization of firebrand piles10.1016/j.firesaf.2018.10.002 ↗
16. Zipperer · 2007 · 192
17. Ignition of mulch and grasses by firebrands in wildland–urban interface fires10.1071/WF06031 ↗
18. On the ignition of fuel beds by firebrands10.1002/fam.901 ↗
19. Quantifying the vulnerabilities of ceramic tile roofing assemblies to ignition during a firebrand attack10.1016/j.firesaf.2009.09.002 ↗
20. Effect of firebrand size and geometry on heating from a smoldering pile under wind10.1016/j.firesaf.2020.103031 ↗
21. Analysis of the thermal exposure and ignition propensity of a lignocellulosic building material subjected to a controlled deposition of glowing firebrands10.1016/j.firesaf.2022.103720 ↗
22. Smoldering ignition using a concentrated solar irradiation spot10.1016/j.firesaf.2022.103549 ↗
23. Ignition of a spot smolder in a moist fuel bed by a firebrand10.1016/j.firesaf.2019.102833 ↗
24. A computational study on the quenching and near-limit propagation of smoldering combustion10.1016/j.combustflame.2021.111937 ↗
25. Review of the transition from smouldering to flaming combustion in wildfires10.3389/fmech.2019.00049 ↗
26. Limiting conditions of smoldering-to-flaming transition of cellulose powder10.1016/j.firesaf.2023.103936 ↗
27. Resurfacing of underground peat fire: smoldering transition to flaming Wildfire on litter surface
28. Smoldering propagation and blow-off on consolidated fuel under external airflow10.1016/j.combustflame.2021.111685 ↗
29. Smouldering-to-flaming transition on wood induced by glowing char cracks and cross wind10.1016/j.fuel.2023.129091 ↗
30. Limiting conditions of smoldering-to-flaming transition of cellulose powder10.1016/j.firesaf.2023.103936 ↗
31. The initiation of smoldering peat fire by a glowing firebrand
32. Absorptivity and its dependence on heat source temperature and degree of thermal breakdown10.1002/fam.1053 ↗
33. Ratio pyrometry of emulated firebrand streaks10.1016/j.firesaf.2023.103746 ↗
34. The propensity of wooden crevices to smoldering ignition by firebrands10.1007/s10694-022-01247-w ↗
35. Critical ignition conditions of wood by cylindrical firebrands10.3389/fmech.2021.630324 ↗
36. Thermal characterization of firebrand piles10.1016/j.firesaf.2018.10.002 ↗
37. Effect of firebrand size and geometry on heating from a smoldering pile under wind10.1016/j.firesaf.2020.103031 ↗
38. Firebrand generation from thermally-degraded cylindrical wooden dowels10.3389/fmech.2019.00032 ↗
39. Exposing decking assemblies to continuous wind-driven firebrand showers
40. An empirical firebrand pile heat flux model10.1016/j.firesaf.2023.104004 ↗
41. Smoldering propagation and blow-off on consolidated fuel under external airflow10.1016/j.combustflame.2021.111685 ↗
42. Analysis of the thermal exposure and ignition propensity of a lignocellulosic building material subjected to a controlled deposition of glowing firebrands10.1016/j.firesaf.2022.103720 ↗
43. Limit conditions of smoldering spread in counterflow configuration: extinction and smoldering-to-flaming transition
44. Smoldering and spontaneous transition to flaming over horizontal cellulosic insulation10.1016/j.proci.2018.05.054 ↗
45. Experimental and theoretical study of the effect of particle size on the forward propagation of smoldering coal10.1016/j.fuel.2021.122903 ↗
46. Propagation of the ignition front in beds of wood particles10.1016/S0010-2180(00)00144-9 ↗
47. Effects of particle size on the self-ignition behaviour of a coal dust layer on a hot plate10.1016/j.fuel.2019.116269 ↗
48. Experimental investigation on the smouldering of pine bark
49. Influence of particle size and density on the hot surface ignition of solid fuel layers10.1007/s10694-018-0782-3 ↗
50. Minimum oxygen supply rate for smouldering propagation : effect of fuel bulk density and particle size10.1016/j.combustflame.2024.113292 ↗