Experimental investigation into fire behaviour of glazed façades with pendant type sprinklers
Source abstract
Abstract
Abstract Facade systems play an important role in fire compartmentation of a building and reducing the likelihood of fire spreading through and outside of the building walls. The use of sprinklers in building regulations often allows for smaller building separation. However, no additional benefits are usually given to additional internal sprinkler protection of the external glass facade using standard pendant sprinklers. Four compartment fire experiments were performed with non-fire-rated aluminium facades with two- and three-layered Insulating Glass Units (IGU), protected by pendant-type sprinklers (DN15, K-factor = 80, T = 68 °C). Sprinklers were in row 14–55 cm from the glazing, with 1.514–1.83 m separation distance. In all experiments, facades achieved satisfactory performance in terms of glazing integrity, insulation and reducing the thermal radiation. Under a non-uniform water distribution, parts of the glass were dry (1.7%–15.7% of IGU area), where we have observed soot deposition and local damage to fire exposed glass layer, but no loss of the structural integrity. The temperatures on the unexposed side did not exceed 86 °C, the peak measured temperature of the internal glass surface was 173 °C. The performed experiments confirmed the capability of standard pendant-type sprinklers to enhance the fire protection features of a building facade.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Structural Analysis of Composite Materials · Flame retardant materials and properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. Zemella · 2004
2. Flammability and multi-objective performance of building façades: towards optimum design
3. The philosophy of fire safety engineering in the shaping of civil engineering development
4. Qualitative analysis of promising materials and technologies for the design and evaluation of Climate Adaptive Opaque Façades10.1016/j.buildenv.2018.08.028 ↗
5. Solar façades: a review10.1016/j.buildenv.2015.01.007 ↗
6. The adaptive solar facade: from concept to prototypes10.1016/j.foar.2016.03.002 ↗
7. Façade-integrated photovoltaics: a life cycle and performance assessment case study10.1002/pip.1167 ↗
8. Falling parts of external walls claddings in case of fire – ITB test method – results comparison10.1051/matecconf/20164602005 ↗
9. Fire resistance glazed construction classifications. Changes in the field of application
10. Fire resistance of aluminium glazed curtain walls: test results comparison depending on the side of fire exposure
11. KRESNIK: a top-down, statistical approach to understand the fire performance of building facades using standard test data10.1016/j.buildenv.2019.106540 ↗
12. ?? F. Turan, Comprehensive study of externally venting flames - Part I: experimental plume characteristics for through-draft and no-through-draft ventilation conditions and repeatability10.1016/S0379-7112(00)00040-0 ↗
13. Model of fire spread out on outer building surface
14. Infrastruktury · 2011 · vol. 859
15. Babrauskas · 2003
16. NFPA · 2018
17. MoBIaE · 2014
18. Malcomson · 1969
19. Fire tests on window assemblies protected by automatic sprinklers10.1007/BF01040427 ↗
20. Moulen · 1975
21. Moulen · 1983
22. Glazing in fire-resistant wall assemblies10.1016/S0950-0618(89)80042-X ↗
23. The protection of glazing systems with dedicated sprinklers10.1177/104239159000200202 ↗
24. ISO 834-1:1999 · 1999
25. Experimental investigation on drag effect of sprinkler spray to adjacent horizontal natural smoke venting
26. Air curtain as a barrier for smoke in case of fire: numerical modelling
27. Sprinkler protection of external glazing10.1023/A:1015325418666 ↗
28. Protection of glazing in fire separations by sprinklers
29. Fire protection of windows using sprinklers
30. Full-scale evaluations on heat resistance of glass panes incorporated with water film or sprinkler in a room fire10.1016/j.buildenv.2006.08.017 ↗
31. Fire test on a non-heat-resistant fireproof glass with down-flowing water film10.3801/IAFSS.FSS.8-327 ↗
32. Maximum temperature to withstand water film for tempered glass exposed to fire10.1016/j.conbuildmat.2014.01.094 ↗
33. Thermal breakage of tempered glass façade with down-flowing water film under different heating rates10.1007/s10694-015-0499-5 ↗
34. Preliminary study on fire protection of window glass by water mist curtain10.1016/j.ijthermalsci.2017.11.013 ↗
35. A study on the development of fire-resistance wall using a cooling system in the tunnel safe station10.9798/KOSHAM.2015.15.3.187 ↗
36. Heat Resistance and Water Protection Effectiveness for Large Single-Pane Fireproof Glass10.1007/s11771-011-0961-6 ↗
37. Modeling glass cooling mechanism with down-flowing water film via the smoothed particle hydrodynamics10.1016/j.cma.2020.112839 ↗
38. Performance-based approach to determining fire safety provisions for buildings in the Asia-Oceania regions10.1016/j.buildenv.2015.04.007 ↗
39. Drysdale · 2011
40. CEN · 2012
41. The adiabatic surface temperature and the plate thermometer10.3801/IAFFS.FSS.10-1001 ↗
42. Kawagoe · 1963
43. Real fire and fire modeling