Validation of CFD fire model pressure predictions for modern residential style structures
Source abstract
Abstract
Controlled gas burner experiments were conducted in single- and two-story residential style structures instrumented with pressure transducers, thermocouples, and bi-directional probes throughout the structures. Exterior doors and window openings were vented in a controlled sequence to investigate the effect of the resulting flow paths on fire-induced flow dynamics and thermal conditions in the structures. The data collected in these experiments provides validation cases for the fire modeling community which currently lacks full-scale data from experiments in realistic residential style structures. The Fire Dynamics Simulator was used to model each scenario in a validation exercise that also investigated the sensitivity of the pressure predictions to the model parameters. The model was capable of predicting the qualitative changes in pressure measurements due to ventilation events as well as the apparent elevation of the neutral plane. Peak pressures were predicted to within 6% on average and quasi-steady static pressures were predicted to within 24% on average. The mean instantaneous error between the experimental pressures and those predicted with the “Localized Leakage” method was approximately 53% compared to 67% with the “Pressure Zone Leakage” method prior to the first ventilation event.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. 2018
2. McGrattan · 2019
3. Fire Dynamics Simulator
4. Salley · 2016 · Supplement 1 · 3
5. Comparison of FDS prediction of smoke movement in a 10-storey building with experimental data10.1007/s10694-008-0075-3 ↗
6. An experimental study of smoke movement in multi-storey buildings10.1007/s10694-009-0132-6 ↗
7. OECD PRISME project: fires in confined and ventilated nuclear-type multi-compartments - overview and main experimental results10.1016/j.firesaf.2013.07.008 ↗
8. Validation of FDS for large-scale well-confined mechanically ventilated fire scenarios with emphasis on predicting ventilation system behavior10.1016/j.firesaf.2013.07.007 ↗
9. 2007
10. Bukowski · 2008
11. Numerical simulation of pressure changes in closed chamber fires10.1016/j.buildenv.2008.09.016 ↗
12. Li · 2015
13. Chow · 2011
14. Experiments and numerical simulations of pressure effects in apartment fires10.1007/s10694-016-0641-z ↗
15. McKinnon · 2020
16. Madrzykowski · 2019
17. Kerber · 2012
18. Kerber · 2013
19. Mattern · 2019
20. 2017
21. Willi · 2021
22. 2018
23. A. Persilly, K. Saito, Airtightness of commercial and institutional buildings: blowing holes in the myth of tight buildings, in: Thermal Envelopes VII Conference.
24. McGrattan · 2019
25. K. McGrattan, S. Miles, SFPE Handbook of Fire Protection Engineering, Springer, fifth ed..
26. Quantifying fire model evaluation using functional analysis10.1016/S0379-7112(99)00029-6 ↗
27. 2008