Fire behaviour of continuous reinforced concrete slabs in a full-scale multi-storey steel-framed building

B. Li, Y.-L. Dong, D.-S. Zhang

Publisher page

Abstract

Abstract To further understand the fire behaviour of reinforced concrete floor slabs, a fire test was performed on six continuous panels (two by three) in a full-scale three-storey steel-framed building. In this paper, the test building, specially designed furnace and relevant experimental phenomena are briefly introduced. The furnace temperatures, temperature distributions, failure patterns as well as horizontal and vertical displacements of some structural components during the heat-up and cool-down phases were recorded and discussed in detail. The test data indicate that deformations of the heated panels have an important relationship with the boundary constraints around the heat panels. The plateau phenomenon of deflections at various measuring points mainly depends on the heated beams around the heated panels. The steel beams do not show partial buckling or failures due to constraints provided by other structural elements. Thus, taking advantage of the intrinsic design strength of the steel beams without applying fire retardant coatings can provide sufficient safety margins in similar engineering design scenarios. Moreover, the cracking characteristics at the upper surface of the heated panels have a direct relationship with the number and location of the heated panels in the floor. Several rational suggestions for the renovation of buildings subjected to fire can be quickly provided by utilising the cracking information.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Engineering and Material Science Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Small-scale concrete slab tests at ambient and elevated temperatures10.1016/j.engstruct.2007.01.023 ↗
2. Membrane action of unrestrained lightly reinforced concrete slabs at large displacements10.1016/S0141-0296(00)00064-X ↗
3. Experimental behaviour of concrete floor slabs at large displacement10.1016/j.engstruct.2004.04.002 ↗
4. Stability of steel columns in case of fire: experimental evaluation10.1061/(ASCE)0733-9445(1998)124:2(158) ↗
5. Experimental investigation of behaviour axially restrained steel beams in fire10.1016/S0143-974X(01)00062-1 ↗
6. Lim · 2002
7. British Steel plc. · 1999
8. Modeling membrane action of concrete slabs in composite buildings in fire. II: validations10.1061/(ASCE)0733-9445(2003)129:8(1103) ↗
9. Modelling of six full-scale fire tests on a composite building
10. Composite steel-framed structures in fire with protected and unprotected edge beams10.1016/j.jcsr.2006.10.001 ↗
11. Composite beams in large buildings under fire-numerical modeling and structural behaviour10.1016/S0379-7112(00)00034-5 ↗
12. C.I. Smith, The broadgate phase eight fire on twenty-third June, 1990, in: Proceeding of the Institution of Mechanical Engineers, Material and Design Against Fire, 1992.
13. Steel frames in fire: analysis10.1016/0141-0296(95)00047-B ↗
14. Experimental study on the behavior of full-scale composite steel frames under furnace loading10.1061/(ASCE)0733-9445(2009)135:10(1278) ↗
15. Thermal and structural response of two-storey two-bay composite steel frames under furnace loading10.1016/j.firesaf.2008.09.005 ↗
16. Fire tests on two-way concrete slabs in a full-scale multi-storey steel-framed building10.1016/j.firesaf.2013.01.023 ↗
17. A fire test on continuous reinforced concrete slabs in a full-scale multi-story steel-framed building10.1016/j.firesaf.2013.08.005 ↗
18. Determination of tensile membrane effects by segment equilibrium,10.1680/macr.2008.62.1.17 ↗
19. Tensile membrane effects of concrete slabs in fire10.1680/macr.2010.62.7.497 ↗
20. Wang · 2000
21. Explosive spalling of high-strength concrete columns in fire,10.1680/macr.2001.53.3.197 ↗
22. Effect of exposure time and rates of heating and cooling on the residual strength of heated concrete,10.1680/macr.1986.38.136.151 ↗
23. Concrete strength for fire safety design10.1680/macr.2005.57.8.445 ↗
24. Thermal and structural behaviour of a full-scale composite building subject to a severe compartment fire10.1016/j.firesaf.2006.07.002 ↗
25. Dong · 2001
26. Eurocode 3: Design of Steel Structures. Part 1.2: General rules-structural Fire Design, Commission of the European Communities, Brussels, 2003.
27. ASTM, Standard Methods of Fire Test of Building Construction Materials, Test Method, ASTM, West Conshohocken, PA, 2001.
28. A numerical model for predicting the fire resistance of reinforced concrete beams10.1016/j.cemconcomp.2007.08.012 ↗
29. Ultimate capacity of composite floor slabs at the fire limit state10.1016/S0958-9465(03)00090-8 ↗
30. A numerical study of large deflection behaviour of restrained steel beams at elevated temperatures10.1016/j.jcsr.2003.09.005 ↗
31. Experimental investigation of behaviour of axially restrained steel beams in fire10.1016/S0143-974X(01)00062-1 ↗
32. BS, Fire Tests on Building Materials and Structures – Part 20: Method from Determination of Fire Resistance of Elements of Construction of Fire Resistance of Element of Construction, BS 476-3:1987, BSi, UK, 1987.