Design of intumescent fire protection for concrete filled structural hollow sections
Source abstract
Abstract
Design of intumescent protection systems for concrete filled structural steel hollow (CFS) sections in the UK typically requires three input parameters in practice: (1) a required fire resistance rating; (2) and 'effective' section factor; and (3) a limiting steel temperature for the hollow structural section. While the first of these inputs is generally prescribed in building codes, the latter two require greater engineering knowledge and judgement. This paper examines results from standard furnace tests on 26 CFS sections, 14 of which were protected with intumescent coatings by application of current UK design guidance. The protected sections demonstrate highly conservative fire protection under standard fire exposure, a conservatism not typically observed for protected unfilled steel hollow sections. The possible causes of the observed conservatism are discussed, and it is demonstrated that the method currently used to calculate the effective section factor for protected CFS columns is based on a false presumption that both unprotected and protected CFS columns can be treated in the same manner. A conservative method for determination of the steel limiting temperature for CFS columns is proposed; this can be applied by designers to more efficiently specify intumescent fire protection for CFS members. © 2014 Elsevier Ltd.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Guidelines for fire resistant design of concrete filled steel HSS columns: state-of-the-art and research needs
2. Communities and Local Government, Approved Document B – Volume 2 – Buildings other than dwelling houses, London, UK, 2007.
3. Lennon · 2007
4. CEN, BS EN 1994-1-2: Eurocode 4: Design of Composite Steel and Concrete Structures, Part 1–2: Structural Fire Design, Brussels, Belgium, 2005.
5. Fire resistant design of concrete filled tubular steel columns,
6. J.M. Aribert, C. Renaud, B. Zhao, Simplified fire design for composite hollow-section columns, in: Proceedings of the Institution of Civil Engineers—Structures and Buildings, 2008, 161, 6, no. December, 325–336.10.1680/stbu.2008.161.6.325 ↗
7. Daniel Madrzykowski, D.W. Stroup, Basics of fire and fire science: flammability hazard of materials, in: Fire Protection Handbook, 20th ed., NFPA, 2008, pp. 2-31–2-48.
8. Hicks · 2002
9. ISO, ISO 834: Fire Resistance Tests-Elements of Building Construction, Geneva, Switzerland, 1999.
10. Rush · 2013
11. CEN · 2010
12. Edwards · 1998
13. CEN · 2009
14. CEN · 2009
15. Paloposki · 2005
16. Lie · 1992