The use of light scattering and ion chamber responses for the detection of fires in diesel contaminated atmospheres
Source abstract
Abstract
Abstract Experiments were conducted to determine the optical scattering properties of diesel particulate matter (DPM) and various combustion aerosols from both flaming and smoldering combustion sources at discrete angles of 15° and 30° in the forward direction and at a light source wavelength of 635 nm using a simple light scattering module. In addition to the scattering data, simultaneous measurements were made of the total aerosol mass concentration; light extinction at an average wavelength of 546 nm; and the response of a common bipolar ion chamber typical of residential smoke detectors modified to allow the aerosols to flow through the chamber. The results of these experiments indicate, for DPM and combustion aerosols, the intensities per unit mass concentration depend not only upon whether the aerosol is DPM or combustion aerosol but also upon the type of combustion aerosol. The results also indicate that the ion chamber responses are greatest for DPM, followed by the response to flaming combustion aerosols (FCA) and lowest for smoldering combustion aerosols (SCA). For light scattering, the greatest intensities are found for SCA, followed by the intensities from FCA, and lowest for DPM. This report describes the experiments, their results, and the use of these results to develop design criteria for early warning fire sensors capable of the rapid and reliable detection of fires in atmospheres that may or may not be contaminated by the products produced from diesel engines.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire Detection and Safety Systems · Fire dynamics and safety research · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Smith CL. Smoke detector operability survey. Report on Findings. US Consumer Product Safety Commission, October 1994. 98pp.
2. Smith LE. Fire incident study. National Smoke Detector Project. US Consumer Product Safety Commission, January 1995. 61pp.
3. Grosshandler WL editor. Nuisance alarms in aircarft cargo areas and critical telecommunications systems. Proceedings of the Third NIST Fire Detector Workshop, NISTIR 6146, BFRL, NIST, March 1998. 34pp.10.6028/NIST.IR.6146 ↗
4. Specific extinction coefficient of flame generated smoke10.1002/1099-1018(200009/10)24:5<227::AID-FAM742>3.0.CO;2-9 ↗
5. Choi MY, Mulholland GW, Hamins A, Kashiwagi T. Experimental study of the optical properties of soot and smoke. NISTIT 5499, NIST, Annual Conference on Fire Research: Book of Abstracts, October 1994. p. 123–4.
6. Sorensen CM, Feke GD. Post-flame soot. Proceedings of the International Conference on Fire Research and Engineering (ICFRE), September 1995. p. 281–5.
7. Mulholland GW, Johnsson EL, Shear DA, Fernandez MG. Design and testing of a new smoke concentration meter. Proceedings of the Fall Conference. Fire Retardant Chemicals Association (FRCA), October 1998. p. 41–9.
8. Gottuk DT, Peatross MJ, Roby RJ, Beyler CL. Advanced fire detection using multi-signature alarm algorithms. Proceedings of the International Conference on Automatic Fire Detection AUBE 99, March 1999. p. 237–46.
9. Milke JA. Application of neural networks for discriminating fire detectors. Proceedings of the International Conference on Automatic Fire Detection AUBE 95, April 1995. p. 213–22.
10. Grosshandler WL. Review of measurements. Candidate Signatures for Early Fire Detection. NISTIR 5555, BFRL, NIST, January 1995. 36pp.
11. Brinn M, Bott B. A fresh approach to mine fire detection. Trans Inst Min Eng 1994; 71–4.
12. Litton CD, Conti RS, Tabacchi JG, Grace R. Evaluation of a nitric oxide-compensated carbon monoxide fire sensor. BuMines IC 9339, 1993. 10pp.
13. Fractal properties of smoke produced from smoldering and flaming fires
14. Edwards JC, Morrow GS. Development of coal combustion sensitivity tests for smoke detectors. US Bureau of Mines Report of Investigations 9551, 1995. 12pp.
15. Microweighing goes on-line in real time
16. Title 30, US Code of Federal Regulations, Part 75.351, July 1, 1995. p. 479.