journal article·2016-08

Thermal performance of LSF floors made of hollow flange channel section joists under fire conditions

Varathananthan Jatheeshan, Mahen Mahendran

Publisher page

Abstract

Light gauge steel frame (LSF) floor systems used in the building industry are made of cold-formed lipped channel section (LCS) joists and lined using gypsum plasterboards. The recently developed LSF floor systems made of welded hollow flange channel (HFC) section joists exhibited superior fire performance in the full scale fire tests. Since full scale fire tests are expensive and time consuming, finite element (FE) models were used in this research on LSF floor systems. In this paper 2-dimensional FE models were developed using a finite element analysis software SAFIR to predict the thermal performance of LSF floors made of HFC joists, and validated using the fire test results. The developed FE models predicted the thermal performance of LSF floor systems exposed to standard fires reasonably well. The validated model was then modified to include plywood subfloor and was used to investigate the effects of important parameters such as joist size, shape and subfloor thickness on the time–temperature profiles of the outer hot and cold flanges of HFC joists. These time–temperature profiles can be directly used to estimate the fire resistance ratings (FRR) of LSF floors made of HFC joists without performing expensive full scale fire tests. This paper presents the details of this thermal analysis study and the results.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Load-Bearing Analysis · Fire effects on concrete materials · Structural Analysis and Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Experimental study of LSF floors made of hollow flange channel section joists under fire conditions
2. A thermal/structural program modelling structures under fire10.62913/engj.v42i3.856 ↗
3. Modelling thermal performance of gypsum plasterboard lined light timber frame walls using SAFIR and TASEF10.1002/fam.1026 ↗
4. Thermal performance of load-bearing cold-formed steel walls under fire conditions using numerical studies10.1260/2040-2317.5.3.261 ↗
5. Keerthan · 2013 · 1993
6. Experimental study of load bearing cold-formed steel wall systems under fire conditions10.1016/j.tws.2013.01.005 ↗
7. Experimental study of load-bearing cold-formed steel walls exposed to realistic design fires10.1260/2040-2317.5.4.291 ↗
8. Standards Australia (SA), Methods for fire tests on building materials, components and structures, Fire-Resistance Tests of Elements of Building Construction, Sydney, AS 1530.4, Australia, 2005.
9. Effect of moisture transfer on specific heat of gypsum plasterboard at high temperatures10.1016/j.conbuildmat.2008.02.016 ↗
10. Thomas · 1997
11. B. Baleshan, M. Mahendran, Full scale fire tests of a new light gauge steel floor-ceiling system, in: Proceedings of the 4th International Conference on Steel and Composite Structures, Sydney, Australia, 2010, pp. 395–401.10.3850/978-981-08-6218-3_SS-Fr021 ↗
12. Sultan · 1996
13. Alfawakhiri · 2001
14. A model for predicting heat transfer through gypsum-board/wood-stud walls exposed to fire10.1002/fam.810180505 ↗
15. Thermal performance of cold-formed thin-walled steel panel systems in fire10.1016/S0379-7112(02)00090-5 ↗
16. Gypsum board in fire-modelling and experimental validation10.1177/0734904107072883 ↗
17. EN 1991-1-2 · 2002
18. EN 1993-1-2 · 2005
19. L. Haughton, C. Murphy, Moisture exchange performance of OSB and plywood structural panels, Research Article, 2003.
20. Jones · 2001
21. Hadvig · 1981 · 9
22. Temperature distribution in a nailed gypsum-stud joint exposed to fire10.1002/fam.810160206 ↗
23. Gammon · 1987
24. M.L. Janssens, Physical properties for wood pyrolysis models, in: Proceedings of Pacific Timber Engineering Conference, Gold Coast, Australia, 1994, pp. 607–618.
25. Performance of structural wood members exposed to fire
26. B. Fredlund, A model for heat and mass transfer in timber structures during fire, A Theoretical, Numerical and Experimental Study, Lund University, Sweden, Institute of Science and Technology, Department of Fire Engineering, Report LUTVDG/(TVBB-1003), 1998, pp. 178.
27. Konig · 2000
28. Numerical study of LSF floors made of hollow flange channels in fire