DSM design of CFS columns subject to distortional buckling at elevated temperatures
Source abstract
Abstract
Abstract Cold-formed steel (CFS) columns are subject to distortional buckling unlike hot-rolled steel columns. Many experimental and numerical investigations have been conducted on the distortional buckling behaviour and capacity of CFS columns at ambient and elevated temperatures. However, constitutive laws of CFS at ambient and elevated temperatures are different with varying levels of nonlinear stress-strain characteristics. Thus, the ultimate distortional buckling capacities predicted by the elevated temperature design rules can be unconservative when the ambient temperature design equations are used with elevated temperature mechanical properties. However, no study has fully incorporated the effects of nonlinear stress-strain characteristics of CFS at elevated temperatures. Therefore, this research study investigated the effects of nonlinear elevated temperature stress-strain characteristics on the distortional buckling capacities of CFS columns using three parameters, namely, nonlinearity, strain hardening and yield strength to Young's modulus ratio, through a numerical parametric study. A comparison of ultimate capacities from the parametric study with those predicted by the current AS/NZS 4600 direct strength method (DSM) showed that the current design equations cannot accurately capture the effects of nonlinear elevated temperature stress-strain characteristics. Consequently, modified DSM equations were proposed to accurately predict the distortional buckling capacities of CFS columns at elevated temperatures.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Fire effects on concrete materials · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Distortional buckling formulas for channel columns10.1061/(ASCE)0733-9445(1987)113:5(1063) ↗
2. Tests of cold-formed channels with local and distortional buckling10.1061/(ASCE)0733-9445(1992)118:7(1786) ↗
3. Schafer · 2000
4. Distortional buckling of CFS stiffened lipped channel compression members10.1061/(ASCE)ST.1943-541X.0001027 ↗
5. On the strength and DSM design of cold-formed steel web/flange-stiffened lipped channel columns buckling and failing in distortional modes10.1016/j.tws.2016.03.023 ↗
6. Structural behaviour of cold-formed thin-walled short steel channel columns at elevated temperatures. Part 2: design calculations and numerical analysis10.1016/S0263-8231(03)00003-X ↗
7. Cold-formed steel lipped channel columns at elevated temperatures10.1016/j.engstruct.2006.12.004 ↗
8. Distortional buckling tests of cold-formed steel compression members at elevated temperatures10.1016/j.jcsr.2008.09.002 ↗
9. DSM to predict distortional failures in cold-formed steel columns exposed to fire: effect of the constitutive law temperature-dependence10.1016/j.compstruc.2014.09.021 ↗
10. DSM design of cold-formed steel columns failing in distortional modes at elevated temperatures10.1007/s13296-018-0184-x ↗
11. 2005
12. Behaviour and design of cold-formed steel beams subject to lateral-torsional buckling10.1016/j.tws.2011.10.012 ↗
13. Standards Australia · 2018
14. Elevated temperature mechanical properties of cold-rolled steel sheets and cold-formed steel sections10.1016/j.jcsr.2019.105851 ↗
15. Effects of nonlinear elevated temperature stress-strain characteristics on the global buckling capacities of cold-formed steel columns10.1016/j.tws.2020.107352 ↗
16. Design of cold-formed steel columns subject to local buckling at elevated temperatures10.1016/j.jcsr.2021.106539 ↗
17. Dassault Systems Simulia Corporation · 2017
18. Buckling analysis of cold-formed steel members using CUFSM: conventional and constrained finite strip methods
19. On the direct strength design of cold-formed steel columns failing in local-distortional interactive modes10.1016/j.tws.2017.06.027 ↗
20. Local, distortional, and Euler buckling of thin-walled columns10.1061/(ASCE)0733-9445(2002)128:3(289) ↗
21. Numerical analysis of cold-formed steel members
22. Numerical modelling of light gauge cold-formed steel compression members subjected to distortional buckling at elevated temperatures10.1016/j.tws.2009.11.004 ↗
23. Experimental study of the mechanical properties of light gauge cold-formed steels at elevated temperatures10.1016/j.firesaf.2008.06.006 ↗
24. Computational modelling of cold-formed steel: characterizing geometric imperfections and residual stresses10.1016/S0143-974X(98)00007-8 ↗
25. Post-buckling of geometrically imperfect plates10.1061/JSDEAG.0003145 ↗
26. Specification for the cold-formed steel structural members
27. Winter · 1968
28. A simple model for the fire resistance of axially loaded members comparison with experimental results10.1016/0143-974X(96)00008-9 ↗
29. Experimental investigation of cold-formed steel material at elevated temperatures10.1016/j.tws.2006.11.003 ↗
30. Review of the high temperature mechanical and thermal properties of the steels used in cold-formed steel structures – the case of the S280 Gd+Z steel10.1016/j.tws.2015.06.002 ↗
31. Experimental investigation of the mechanical properties of ZAR-345 cold-formed steel at elevated temperatures10.1590/1516-1439.297014 ↗
32. Mechanical properties of cold-formed steels at elevated temperatures10.1016/j.tws.2010.08.004 ↗
33. Ramberg · 1943