Fire resistance of a fully concealed, moment-resisting new timber connection utilizing mechanically-fastened steel rods
Source abstract
Abstract
One major hindrance to more utilization of timber in the construction of tall buildings is the limited fire resistance of the connections between its structural elements. In an experimental study that aimed to investigate the structural behaviour of a new connection configuration that utilizes fully concealed, mechanically fastened steel rods, eight (8) full-size glued-laminated timber beam-end connections were tested under the CAN/ULC-S101 standard time-temperature curve. Test variables investigated in this study included rod anchorage length (200 and 250 mm) and washer size (38.1 × 38.1 and 50.8 × 50.8 mm). Results show that using the smaller washer provided more wood side cover to protect the steel components from the effects of elevated temperatures. Also, utilizing longer rod anchorage length provided larger internal surface area of the wood prism to better resist shear stresses as well as longer length for the rods to bear against the wood at high rotation values of the connection. By combining the said two aspects (longer anchorage length and smaller washer) a fully concealed glulam beam-end connection that utilizes only two mechanically-fastened steel rods can be successfully designed to achieve a 1-h fire resistance without the application of additional fire protection.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Wood Treatment and Properties · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. A contemporary review of large-scale non-standard structural fire testing10.1186/2193-0414-2-1 ↗
2. Thermo-mechanical analysis of the fire performance of dowelled timber connection10.1016/j.engstruct.2009.12.041 ↗
3. Fire resistance performance of unprotected wood–wood–wood and wood–steel–wood connections: a literature review and new data correlations10.1016/j.firesaf.2010.08.003 ↗
4. Behavior of dowelled and bolted steel-to-timber connections exposed to fire10.1016/j.engstruct.2012.02.010 ↗
5. Fire resistance tests on timber beam-to-column shear connections10.1108/JSFE-03-2016-004 ↗
6. Structural fire performance of wood-steel-wood bolted connections with and without perpendicular-to-wood grain reinforcement
7. Determination of fire resistance ratings for glulam connectors within US high rise timber buildings10.1016/j.firesaf.2017.04.028 ↗
8. Palma · 2013
9. Timber frame moment joints with glued-in steel rods. I: design10.1061/(ASCE)ST.1943-541X.0000419 ↗
10. Timber frame moment joints with glued-in steel rods. II: experimental investigation of long-term performance10.1061/(ASCE)ST.1943-541X.0000517 ↗
11. Batchelar · 1998 · vol. 1 · 289
12. Influence of elevated temperature on glued-in steel rods for timber elements10.1016/j.conbuildmat.2017.04.038 ↗
13. Experimental determination of the pull-out strength of mechanically fastened steel rods into glulam beam sections having different rod lengths and washer sizes10.1016/j.engstruct.2021.112270 ↗
14. C. Hubbard, Fire Performance of a Novel Concealed Mass Timber Moment-Resisting Connection Utilizing Mechanically-Fastened Steel Rods. Master’s disseratation. Dept. of Civil engineering, Lakehead University, Ontario, Canada.
15. 2014
16. 2018
17. 2019
18. 2013
19. 2018
20. Thermo-hydric transfer within timber connections under fire exposure: experimental and numerical investigations10.1016/j.applthermaleng.2013.10.049 ↗