Experimental investigation of cellular steel beams at ambient and elevated temperatures

Luana V. da Silva, Nickolas Giacomitti, Débora Ferreira, Nuno Lopes, Luís M.R. Mesquita

Fire Safety Journal· Volume 159

Abstract

Cellular steel beams, commonly used in modern construction, exhibit complex failure mechanisms that have not been thoroughly explored, especially under fire conditions. This research investigates the structural behaviour of cellular beams under both ambient and elevated temperatures, with a focus on load-bearing capacity and failure modes. Experimental tests were conducted on a solid beam and six cellular beams with varying hole spacings and diameters at different temperatures. All beams were tested under three-point bending, subjecting the openings and the web posts to different combinations of bending moments and shear forces. Experimental maximum loads and failure modes are compared with the design method of EN1993-1-13 and EN1993-1-2. At ambient temperature, failure modes varied with beam design: specimens with smaller opening spacings failed by web-post buckling, while larger openings resulted in a Vierendeel mechanism. While the Eurocode predictions for load capacity were conservative under ambient conditions, the design model did not accurately predict the correct failure mode. Elevated temperatures significantly reduced the load capacity and, in some cases, changed the collapse mechanism. These results highlight that current design rules are unreliable in predicting the failure mode and may not ensure safety at higher temperatures, stressing the need for specific design rules for cellular beams in fire conditions.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Fares · 2016
2. Design of composite beams with large web openings
3. Elastic lateral-torsional buckling of cellular beams10.1016/j.istruc.2024.106392 ↗
4. Two-stage framework for lateral-torsional buckling resistance prediction of cellular steel beams under fire conditions10.1016/j.istruc.2024.107157 ↗
5. Design procedure for the web-post buckling of steel cellular beams10.1016/j.jcsr.2018.06.020 ↗
6. Application of artificial neural networks for web-post shear resistance of cellular steel beams10.1016/j.tws.2020.107414 ↗
7. Web-post buckling prediction resistance of steel beams with elliptically-based web openings using Artificial Neural Networks (ANN)10.1016/j.tws.2022.109959 ↗
8. Enhancing web-post buckling resistance in perforated steel beams: an in-depth investigation of elliptical openings, geometric parameters, and ai-driven predictions10.1016/j.istruc.2024.107907 ↗
9. Shear behavior of I-section steel with circular web opening and novel reinforcement10.1016/j.jcsr.2022.107637 ↗
10. Novel simplified equations for Vierendeel design of beams with (elongated) circular openings10.1016/j.jcsr.2015.04.007 ↗
11. A practical design formulation for perforated beams with openings strengthened with ring type stiffeners subject to Vierendeel actions
12. Comparative analysis of fire-adapted models for the shear buckling strength of web-posts in castellated steel beams10.1016/j.firesaf.2023.103796 ↗
13. 2024
14. 2024
15. A new proposal for the design of laterally unrestrained cellular steel beams under moment gradient at elevated temperatures10.1016/j.firesaf.2023.103812 ↗
16. Behaviour of cellular steel beams at ambient and high-temperature conditions10.1016/j.jcsr.2023.107969 ↗
17. Shear behaviour and strength design of cellular beams with circular or elongated openings10.1016/j.tws.2020.107353 ↗
18. Experimental and numerical investigations towards the lateral torsional buckling of cellular steel beams10.1016/j.tws.2023.111388 ↗
19. Experimental study and structural analysis of tapered steel beams with cellular openings10.1016/j.engstruct.2023.116212 ↗
20. Lateral–torsional buckling resistance of cellular beams10.1016/j.jcsr.2014.11.003 ↗
21. Ultimate load carrying capacity of optimally designed steel cellular beams10.1016/j.jcsr.2012.10.007 ↗
22. Web buckling study of the behaviour and strength of perforated steel beams with different novel web opening shapes10.1016/j.jcsr.2011.04.004 ↗
23. An experimental and parametric study on steel beams with web openings10.1007/s40091-015-0095-4 ↗
24. Behavior of cellular beams protected with intumescent coatings
25. Indicative fire tests to investigate the behaviour of cellular beams protected with intumescent coatings10.1016/j.firesaf.2004.06.007 ↗
26. Large-scale fire test of unprotected cellular beam acting in membrane action
27. Experimental and numerical analysis of stainless steel cellular beams in fire10.1016/j.firesaf.2021.103277 ↗
28. Experimental and numerical modelling of cellular beams with circular and elongated web openings at elevated temperatures10.1260/2040-2317.2.4.289 ↗
29. Experimental study on fire behavior of steel–concrete composite cellular beams with large opening ratio10.1007/s13296-019-00281-9 ↗
30. Structural behaviour of a novel modular cellular steel beam system at elevated temperatures based on large-scale experimental testing and numerical modelling10.1016/j.jcsr.2022.107512 ↗
31. 2005
32. Design of hybrid steel girders10.1016/S0143-974X(03)00128-7 ↗
33. 2018
34. 1997
35. 2001
36. An experimental and parametric study on steel beams with web openings10.1007/s40091-015-0095-4 ↗
37. 2020
38. Fire behaviour of cellular composite floor steel beams with different web opening shapes10.3801/IAFSS.FSS.10-1537 ↗
39. Design of cellular members under axial-shear-flexure interaction