journal article·2014-07

Position of Maximum Ceiling Temperature in a Tunnel Fire

Ying Zhen Li, Haukur Ingason

Fire Technology· Volume 50· Issue 4
Publisher page

Abstract

The position of the maximum ceiling gas temperature indicates how far the fire plum could be blown away by a ventilation flow. It could be applied to estimate the activation of a detection system or a sprinkler system, or to estimate the range of damage to the tunnel structure. An equation for predicting the position of the maximum ceiling gas temperature in a tunnel fire is proposed based on a theoretical analysis and validated using both laboratory test data and full scale test data. A flame angle has been defined based on the position of the maximum ceiling temperature in a tunnel fire. The flame angle is directly related to the dimensionless ventilation velocity, and it becomes insensitive to the heat release rate for a large tunnel fire. Further, it is found that a constant critical flame angle exists, defined as the flame angle under the critical condition when the backlayering just disappears. For a given tunnel and fire source, the flame angle under critical conditions is the same value, independent of heat release rate, and the maximum ceiling temperature under critical conditions always corresponds to the same position. Generally the horizontal distance between the position of the maximum ceiling temperature and the fire source centre is around 1.5 times the effective tunnel height under the critical condition.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire effects on ecosystems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. ISO (1999) Fire-resistance tests: elements of building construction—part 1: general requirements. International Organization for Standardization, Geneva
2. European Committee for Standardization (1999) Fire resistance tests: part 2: alternative and additional procedures. European Committee for Standardization, Brussels
3. Instituut TNO voor Bouwmaterialen en Bouwconstructies (1979) Beproeving van het gedrag bij verhitting van twee isolatiematerialen ter bescherming van tunnels bij brand, Instituut TNO voor Bouwmaterialen en Bouwconstructies, B-79-391, Delft
4. Li YZ, Lei B, Ingason H (2011) The maximum temperature of buoyancy-driven smoke flow beneath the ceiling in tunnel fires. Fire Saf J 46:204–21010.1016/j.firesaf.2011.02.002 ↗
5. Li YZ, Ingason H (2012) The maximum ceiling gas temperature in a large tunnel fire. Fire Saf J 48:38–4810.1016/j.firesaf.2011.12.011 ↗
6. American Gas Association (1974) LNG safety research program, report IS 3-1. American Gas Association, Washington, DC
7. Kurioka H, Oka Y, Satoh H, Sugawa O (2003) Fire properties in near field of square fire source with longitudinal ventilation in tunnels. Fire Saf J 38:319–34010.1016/S0379-7112(02)00089-9 ↗
8. Quintiere JG, Rinkinen WJ, Jones WW (1981) The effect of room openings on fire plume entrainment. Combust Sci Technol 26:193–20110.1080/00102208108946960 ↗
9. Karlsson B, Quintiere JG (2000) Enclosure fire dynamics. CRC Press, Washington DC, pp 53–64
10. Li YZ, Lei B, Ingason H (2010) Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires. Fire Saf J 45(6–8):361–370
11. Ingason H, Li YZ (2010) Model scale tunnel fire tests with longitudinal ventilation. Fire Saf J 45(6–8):371–38410.1016/j.firesaf.2010.07.004 ↗
12. Quintiere JG (1989) Scaling applications in fire research. Fire Saf J 15:3–2910.1016/0379-7112(89)90045-3 ↗
13. Heskestad G (1975) Physical modeling of fire. J Fire Flammabil 6:253–273
14. Li YZ, Ingason H (2010) Maximum ceiling temperature in a tunnel fire. SP report 2010:51. SP Technical and Research Institute of Sweden, Boras
15. Ingason H, Lönnermark A(2005) Heat release rates from heavy goods vehicle trailers in tunnels. Fire Saf J 40:646–66810.1016/j.firesaf.2005.06.002 ↗
16. Lönnermark A, Ingason H (2005) Gas temperatures in heavy goods vehicle fires in tunnels. Fire Saf J 40:506–52710.1016/j.firesaf.2005.05.003 ↗
17. Lönnermark A, Ingason H (2006) Fire spread and flame length in large-scale tunnel fires. Fire Technol 42:283–30210.1007/s10694-006-7508-7 ↗
18. FHWA (1995) Memorial tunnel fire ventilation test program—test report. Massachusetts Highway Department and Federal Highway Administration, Massachusetts
19. Lemaire T, van de Leur PHE, Kenyon YM (2002) Safety proef: TNO metingen beneluxtunnel—meetrapport. TNO, TNO-rapport 2002-CVB-R05572. TNO, Amsterdam
20. Lemaire T, Kenyon Y (2006) Large scale fire tests in the Second Benelux tunnel. Fire Technol 42:329–35010.1007/s10694-006-8434-4 ↗