The Reduced Cross-Section Method for Evaluation of the Fire Resistance of Timber Members: Discussion and Determination of the Zero-Strength Layer
Source abstract
Abstract
The reduced cross-section method (RCSM) is included in Eurocode 5 (EN-1995-1-2) for the design of timber members in fire conditions. The method considers the strength and stiffness reduction beneath the charred layer by adding an additional depth (known as the ‘zero-strength’ layer) to the charring depth. The zero-strength layer is one of the key parameters for the fire design of timber members. Recently, some concerns have been raised that the zero-strength layer might be non-conservative in some applications. This paper presents the background to the RCSM, followed by a short discussion on the mechanical assumptions, simplifications and possible limitations of the method itself. Further, it discusses determination of the zero-strength layer thickness for members in bending, tension and compression, and provides guidelines on the use of standard experimental tests to determine this quantity. For demonstration of the determination procedure, the results of fire tests in bending, tension and compression were analysed following the described procedure. Results show that the zero-strength layer exceeds the value used in practice, indicate that the method of Eurocode 5 may be non-conservative and should be revised.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Wood Treatment and Properties · Fire dynamics and safety research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Malhotra HL, Rogowski BF (1967) Fire resistance of laminated timber columns. Fire Research Station
2. Lie TT (1977) A method for assessing the fire resistance of laminated timber beams and columns. Can J Civil Eng 4:161–16910.1139/l77-021 ↗
3. Meyer-Ottens C (1976) Feuerwiderstandsdauer unbekleideter Holzbalken mit Rechteckquerschnitt, Institut für Baustoffkunde und Stahlbetonbau der Technischen Universität Braunschweig, Cologne, Germany
4. EN 1995-1-2 (2004) Design of timber structures—Part 1-2: General—Structural fire design. CEN, European Committee for Standardization, Brussels
5. Frangi A, Fontana M (2003) Charring rates and temperature profiles of wood sections. Fire and Mater 27: 91–10210.1002/fam.819 ↗
6. Haksever A (1976) Untersuchungsbericht zum Brandverhalten von brettschichtverleimten Holzstützen mit Rechteckquerschnitt., Technische Universität Braunschweig, Germany
7. Schaffer E (1977) State of structural timber fire endurance. Wood Fiber Sci 9:145–170
8. Schaffer EL (1984) Structural fire design: wood, U.S. Dept. of Agriculture, Madison, WI
9. Collier P, Buchanan A (2002) Fire resistance of lightweight timber framed walls. Fire Technol 38:125–14510.1023/A:1014459216939 ↗
10. König J (2005) Structural fire design according to Eurocode 5—design rules and their background. Fire Mater 29: 147–16310.1002/fam.873 ↗
11. Schmid J, König J, Just A (2012) The Reduced Cross-Section Method for the design of timber structures exposed to fire-background, limitations and New developments. Struct Eng Int 22:514–2210.2749/101686612X13363929517578 ↗
12. Schmid J, Klippel M, Just A, Frangi A (2014) Review and analysis of fire resistance tests of timber members in bending, tension and compression with respect to the Reduced Cross-Section Method Fire Safety Journal10.1016/j.firesaf.2014.05.006 ↗
13. König J, Schmid J (2010) Light timber frame constructions with solid timber members—application of the Reduced Cross-sction Method. Conference proceedings. CIB W18-Meeting 43, Nelson, New Zealand, Lehrstuhl für Ingenieurholzbau, University of Karlsruhe, Karlsruhe, Germany
14. Fragiacomo M, Menis A, Moss PJ, Clemente I, Buchanan AH, Nicolo B (2013) Predicting the fire resistance of timber members loaded in tension. Fire Mater 37:114–12910.1002/fam.2117 ↗
15. Fragiacomo M, Menis A, Moss P, Buchanan A, Clemente I (2010) Numerical and experimental evaluation of the temperature distribution within laminated veneer lumber (LVL) members exposed to fire. J Struct Fire Eng 1: 145–15910.1260/2040-2317.1.3.145 ↗
16. Klippel M, Schmid J, Frangi A (2012) The Reduced Cross-section Method for timber members subjected to compression, tension and bending in fire. International Council for Research and Innovation in Building and Construction, Working Commission W18—Timber Structures, Meeting 45 (CIB-W18 Meeting 2012), Växjö, Sweden. p. CIB-W18/45-16-1
17. Schaffer EL (1967) Charring rate of selected Woods—Transverse to Grain, Forest Products Lab, Madison, Wisconsin
18. White RH, Schaffer EL (1981) Transient moisture gradient in fire-exposed wood slab. Wood Fiber Sci 13:17–38
19. Lingens A (2003) Untersuchung des Abbrandes und der Brandgase ausgewählter Holzarten in Abhängigkeit vom chemischen und strukturellen Holzaufbau. Technische Universität München, Universitätsbibliothek
20. König J, Walleij L (1999) One-dimensional charring of timber exposed to standard and parametric fires in initially unprotected and postprotection situations, SP Technical Research Institute of Sweden, Wood Technology, Stockholm, Sweden
21. Cachim P, Franssen J-M (2010) Assessment of Eurocode 5 Charring Rate Calculation Methods. Fire Technol 46: 169–18110.1007/s10694-009-0092-x ↗
22. Collier PCR (1992) Charring rates of timber, Branz, Study report 42, Judgeford, New Zealand
23. White R, Nordheim E (1992) Charring rate of wood for ASTM E 119 exposure. Fire Technol 28:5–3010.1007/BF01858049 ↗
24. König J (2006) Effective thermal actions and thermal properties of timber members in natural fires. Fire Mater 30: 51–6310.1002/fam.898 ↗
25. König J, Walleij L (2000) Timber Frame Assemblies Exposed to Standard and Parametric Fires—Part 2: a design model for standard fire exposure, Swedish Institute for Wood Technology Research, Stockholm, Sweden
26. Ödeen K (1970) Fire Resistance of Glued, Laminated Timber Structures. Symposium No. 3 Fire and Structural Use of Timber in Buildings, Fire Research Station, Borehamwoods, Herts, on 25th October, 1967, 1970
27. Thomas G (1997) Fire Resistance of Light Timber Framed Walls and Floors, University of Canterbury, Fire Research Report 97/7, Christchurch
28. EN 1995-1-1 (2004) Design of timber structures—Part 1-1: General-Common rules and rules for buildings. CEN, European Committee for Standardization, Brussels
29. EN 1363-1 (1999) Fire resistance tests—Part 1: General requirements. CEN, European Committee for Standardization, Brussels
30. EN 1365-1:2012/AC:2013 Fire resistance tests for loadbearing elements—Part 1: Walls CEN, European Committee for Standardization, Brussels
31. EN 1365-2 (2000) Fire resistance tests for loadbearing elements—Part 2: Floors and roofs CEN, European Committee for Standardization, Brussels
32. EN 1365-3 (2000) Fire resistance tests for loadbearing elements—Part 3: Beams. CEN, European Committee for Standardization, Brussels
33. EN 1365-4 (1999) Fire resistance tests for loadbearing elements—Part 4: Columns CEN, European Committee for Standardization, Brussels
34. Lange D, Boström L, Schmid J, Albrektsson J (2014) Assessment of the influence of parametric fire scenarios on structural timber performance and reliability, SP Swedish Technical Research Institute, SP Report 2014:35, ISBN 978-91-87461-78-1, Borås, Sweden
35. König J (1995) Fire Resistance of Timber Joists and Load Bearing Wall Frames, Trätek, Institutet för träteknisk forskning, I9412071, Stockholm
36. Klippel M, Frangi A, Hugi E (2013) Experimental Analysis on the Fire Behavior of Finger-Jointed Timber Members. ASCE J Struct Eng 140(3): 0401306310.1061/(ASCE)ST.1943-541X.0000851 ↗
37. EN 13381-4 (2013) Test methods for determining the contribution to the fire resistance of structural members—Part 4: applied passive protection to steel members CEN, European Committee for Standardization, Brussels
38. ISO 834 (1999) Fire-resistance tests—elements of building construction—Part 1: general requirements In. International Organisation for Standardisation
39. EN 408 (2010) Timber structures—Structural timber and glued laminated timber—Determination of some physical and mechanical properties. CEN, European Committee for Standardization, Brussels
40. Klippel M, Frangi A (2014) Fire tests on finger-jointed timber boards—Test report, vdf Hochschul-Verlag an der ETH Zürich, Zürich
41. EN 384 (2010) Structural timber—Determination of characteristic values of mechanical properties and density. CEN, European Committee for Standardization, Brussels
42. BFS 1993:58 - BKR 1; Boverkets konstruktionsregler (föreskrifter och allmänna råd), including changes. BOV BAoS, Stockholm, 2011
43. Peter M, Göckerl T, Bemessung von Voll- und Brettschichtholzbauteilen aus maschinell sortiertem Schnittholz für den Brandfall—Teil 2: Brandversuche zur Bestätigung der theoretischen Ergebnisse. (in German) Institut des Zimmerer- und Holzbaugewerbes e.V., Berlin, 2006
44. EN 338 (2009) Structural timber—Strength classes. CEN, European Committee for Standardization, Brussels
45. EN 1194 (1999) Timber structures—Glued laminated timber—Strength classes and determination of characteristic values. CEN, European Committee for Standardization, Brussels