Numerical Investigation on the Influence of Length–Width Ratio of Fire Source on the Smoke Movement and Temperature Distribution in Tunnel Fires
Source abstract
Abstract
The behaviors hot and toxic smoke in tunnel fires is important to the engineering applications of fire protection systems. The shapes of fire source may affect the characteristics of smoke movement in tunnels. In the current study, a numerical investigation is conducted to explore the effect of fire source shape on the smoke movement and temperature distribution in a full scale road tunnel. The area of fire was fixed with the length–width ratio (n) varying from 1 to 11 and the heat release rate (HRR) of the fire source varying from 5 MW to 15 MW. Results show that with increasing HRR and decreasing n, the impinging flow on the tunnel ceiling transits from buoyancy plume to continuous flame and the smoke becomes more difficultly to be uniform along the longitudinal direction, resulting in further starting position of one-dimensional spread stage (L). Due to the change of entrainment behavior, for a certain HRR, the smoke mass flow rate decreases with decreasing n, which is proportional to the perimeter of the fire source. As n decreases from 11 to 1, the smoke mass flow rate decreases for 23%. Moreover, a correlation of the longitudinal smoke temperature distribution under the tunnel ceiling is developed, with the temperature at the initial position of the one-dimension spread stage as the reference value. This study obtains the variation laws of smoke mass flow and temperature distribution under the effects of fire source shape. It can provide a reference for the smoke control and safe evacuation in straight tunnel without forced flow.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Evacuation and Crowd Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Wang YF, Sun XF, Liu S, Yan PN, Qin T, Zhang B (2016) Simulation of back-layering length in tunnel fire with vertical shafts. Appl Therm Eng 109:344–350. https://doi.org/10.1016/j.applthermaleng.2016.08.08110.1016/j.applthermaleng.2016.08.081 ↗
2. Ji J, Fan CG, Zhong W, Shen XB, Sun JH (2012) Experimental investigation on influence of different transverse fire locations on maximum smoke temperature under the tunnel ceiling. Int J Heat Mass Transf 55(17-18):4817–4826. https://doi.org/10.1016/j.ijheatmasstransfer.2012.04.05210.1016/j.ijheatmasstransfer.2012.04.052 ↗
3. Alarie Y (2002) Toxicity of fire smoke. Crit Rev Toxicol 32(4):259–289. https://doi.org/10.1080/2002409106424610.1080/20024091064246 ↗
4. Gao ZH, Ji J, Fan CG, Sun JH (2015) Experimental analysis of the influence of accumulated upper hot layer on the maximum ceiling gas temperature by a modified virtual source origin concept. Int J Heat Mass Transf 84:262–270. https://doi.org/10.1016/j.ijheatmasstransfer.2015.01.00610.1016/j.ijheatmasstransfer.2015.01.006 ↗
5. Baek D, Sung, KH, Ryou HS (2017) Experimental study on the effect of heat release rate and aspect ratio of tunnel on the plug-holing phenomena in shallow underground tunnels. Int J Heat Mass Transf 113:1135–1141. https://doi.org/10.1016/j.ijheatmasstransfer.2017.06.04410.1016/j.ijheatmasstransfer.2017.06.044 ↗
6. Vauquelin O (2008) Experimental simulations of fire-induced smoke control in tunnels using an “air–helium reduced scale model”: principle, limitations, results and future. Tunn Undergr Space Technol 23(2):171–178. https://doi.org/10.1016/j.tust.2007.04.00310.1016/j.tust.2007.04.003 ↗
7. Ji J, Wan H, Li K, Han J, Sun J (2015) A numerical study on upstream maximum temperature in inclined urban road tunnel fires. Int J Heat Mass Transf 88:516–526. https://doi.org/10.1016/j.ijheatmasstransfer.2015.05.00210.1016/j.ijheatmasstransfer.2015.05.002 ↗
8. Li YZ, Ingason H (2012) The maximum ceiling gas temperature in a large tunnel fire. Fire Saf J 48:38–48. https://doi.org/10.1016/j.firesaf.2011.12.01110.1016/j.firesaf.2011.12.011 ↗
9. Delichatsios MA (1981) The flow of fire gases under a beamed ceiling. Combust Flame 43:1–10. https://doi.org/10.1016/0010-2180(81)90002-X10.1016/0010-2180(81)90002-X ↗
10. Hurley MJ, Gottuk DT, Hall Jr JR, Harada K, Kuligowski ED, Puchovsky M, Torero JL, Watts Jr JM, Wieczorek CJ (Eds) (2015) SFPE handbook of fire protection engineering. Springer, Berlin
11. Yang D, Huo R, Zhang XL, Zhao XY (2011). On the front velocity of buoyancy-driven transient ceiling jet in a horizontal corridor: comparison of correlations with measurements. Appl Therm Eng 31(14–15):2992–2999. https://doi.org/10.1016/j.applthermaleng.2011.05.03110.1016/j.applthermaleng.2011.05.031 ↗
12. Ji J, Guo F, Gao Z, Zhu J (2018) Effects of ambient pressure on transport characteristics of thermal-driven smoke flow in a tunnel. Int J Therm Sci 125:210–217. https://doi.org/10.1016/j.ijthermalsci.2017.11.02710.1016/j.ijthermalsci.2017.11.027 ↗
13. Hasemi Y, Nishihata M (1989) Fuel shape effect on the deterministic properties of turbulent diffusion flames. Bull Jpn Assoc Fire Sci Eng 38(2):29–34. https://doi.org/10.11196/kasai.38.2_2910.11196/kasai.38.2_29 ↗
14. Fan CG, Ji J, Li YZ, Ingason H, Sun JH (2017) Experimental study of sidewall effect on flame characteristics of heptane pool fires with different aspect ratios and orientations in a channel. Proc Combust Inst 36(2):3121–3129. https://doi.org/10.1016/j.proci.2016.06.19610.1016/j.proci.2016.06.196 ↗
15. Tang F, Zhu K, Dong M, Shi Q (2015) Mean flame height and radiative heat flux characteristic of medium scale rectangular thermal buoyancy source with different aspect ratios in a sub-atmospheric pressure. Int J Heat Mass Transf 84:427–432. https://doi.org/10.1016/j.ijheatmasstransfer.2015.01.03710.1016/j.ijheatmasstransfer.2015.01.037 ↗
16. Miltner M, Jordan C, Harasek M (2015) CFD simulation of straight and slightly swirling turbulent free jets using different RANS-turbulence models. Appl Therm Eng 89:1117–1126. https://doi.org/10.1016/j.applthermaleng.2015.05.04810.1016/j.applthermaleng.2015.05.048 ↗
17. Zhong W, Fan CG, Ji J, Yang JP (2013) Influence of longitudinal wind on natural ventilation with vertical shaft in a road tunnel fire. Int J Heat Mass Transf 57(2):671–678. https://doi.org/10.1016/j.ijheatmasstransfer.2012.10.06310.1016/j.ijheatmasstransfer.2012.10.063 ↗
18. Ji J, Guo F, Gao Z, Zhu J, Sun J (2017) Numerical investigation on the effect of ambient pressure on smoke movement and temperature distribution in tunnel fires. Appl Therm Eng 118:663–669. https://doi.org/10.1016/j.applthermaleng.2017.03.02610.1016/j.applthermaleng.2017.03.026 ↗
19. Ang CDE, Rein G, Peiro J, Harrison R (2016) Simulating longitudinal ventilation flows in long tunnels: comparison of full CFD and multi-scale modelling approaches in FDS6. Tunn Undergr Space Technol 52:119–126. https://doi.org/10.1016/j.tust.2015.11.00310.1016/j.tust.2015.11.003 ↗
20. McGrattan K, Hostikka S, McDermott R, Floyd J, Weinschenk C, Overholt K (2013) Fire dynamics simulator, user’s guide. NIST Spec Publ 1019:20
21. Ji J, Gao ZH, Fan CG, Sun JH (2013) Large Eddy Simulation of stack effect on natural smoke exhausting effect in urban road tunnel fires. Int J Heat Mass Transf 66:531–542. https://doi.org/10.1016/j.ijheatmasstransfer.2013.07.05710.1016/j.ijheatmasstransfer.2013.07.057 ↗
22. Kunsch JP (1998) Critical velocity and range of a fire-gas plume in a ventilated tunnel. Atmos Environ 33(1):13–24. https://doi.org/10.1016/S1352-2310(98)00118-610.1016/S1352-2310(98)00118-6 ↗
23. Kunsch JP (2002) Simple model for control of fire gases in a ventilated tunnel. Fire Saf J 37(1):67–81. https://doi.org/10.1016/S0379-7112(01)00020-010.1016/S0379-7112(01)00020-0 ↗
24. Thomas PH (1963) Investigations into the flow of hot gases in roof venting. Fire research technical paper, p 7
25. Hinkley PL (1986) Rates of ‘production’ of hot gases in roof venting experiments. Fire Saf J 10(1):57–65. https://doi.org/10.1016/0379-7112(86)90032-910.1016/0379-7112(86)90032-9 ↗
26. Wan H, Gao Z, Ji J, Sun J, Zhang Y, Li K (2018) Predicting heat fluxes received by horizontal targets from two buoyant turbulent diffusion flames of propane burning in still air. Combust Flame 190:260–269. https://doi.org/10.1016/j.combustflame.2017.12.00310.1016/j.combustflame.2017.12.003 ↗
27. Wan H, Ji J, Li K, Huang X, Sun J, Zhang Y (2017) Effect of air entrainment on the height of buoyant turbulent diffusion flames for two fires in open space. Proc Combust Inst 36(2):3003–3010. https://doi.org/10.1016/j.proci.2016.07.07810.1016/j.proci.2016.07.078 ↗
28. Gao ZH, Liu ZX, Wan HX, Zhu JP (2016) Experimental study on longitudinal and transverse temperature distribution of sidewall confined ceiling jet plume. Appl Therm Eng 107:583–590. https://doi.org/10.1016/j.applthermaleng.2016.07.00710.1016/j.applthermaleng.2016.07.007 ↗
29. Ji J, Bi Y, Venkatasubbaiah K, Li K (2016) Influence of aspect ratio of tunnel on smoke temperature distribution under ceiling in near field of fire source. Appl Therm Eng 106:1094–1102. https://doi.org/10.1016/j.applthermaleng.2016.06.08610.1016/j.applthermaleng.2016.06.086 ↗
30. Zhong M, Shi C, He L, Shi J, Liu C, Tian X (2016) Smoke development in full-scale sloped long and large curved tunnel fires under natural ventilation. Appl Therm Eng 108:857–865. https://doi.org/10.1016/j.applthermaleng.2016.07.14110.1016/j.applthermaleng.2016.07.141 ↗
31. Hu LH (2006) Studies on thermal physics of movement in tunnel fires. Ph.D. thesis, University of Science and Technology of China, Hefei