Theoretical and Experimental Study of Critical Velocity for Smoke Control in a Tunnel Cross-Passage
Source abstract
Abstract
Theoretical analyses and model-scale experiments have been conducted to investigate the critical velocity in a tunnel cross-passage which is defined as the minimum ventilation velocity through the fireproof door to prevent smoke from flowing into a cross-passage. The effect of the fireproof door geometry, heat release rate, ventilation velocity and fire source location were taken into account. The critical velocity in a tunnel cross-passage varies approximately as three-second power of the fireproof door height, as one-third power of the heat release rate and as exponential law of the ventilation velocity, almost independent of the fireproof door width. The critical Froude Number range varies mainly between 5 to 10 and consequently as it is not a constant value it is not very suitable to predict the critical velocity in a tunnel cross-passage. A dimensionless correlation that can correlate well with the experimental data was proposed
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire effects on ecosystems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. R. O. Carvel, G. Marlair. A history of fire incidents in tunnels. In: AN Beard and RO Carvel, Editors, The handbook of Tunnel Fire Safety. (A. N. Beard and R. O. Carvel, Eds.), London, Thomas Telford Publishing, 2005, pp. 3-41.
2. Kennedy WD, Parsons B (1996) Critical velocity: past, present and future. Seminar of smoke and critical velocity in tunnels. London, UK, pp 305–322
3. Y. Wu, M.Z.A. Bakar. Control of smoke flow in tunnel fires using longitudinal ventilation systems - a study of the critical velocity. Fire Safety Journal. 2000; 35:363-390.10.1016/S0379-7112(00)00031-X ↗
4. Hall RC (2006) Ventilation during road tunnel emergencies. Published project report, PPR140. TRL Limited, Berkshire
5. D. H. Kim, W.H. Park. Experiment by using reduced scale models for the fire safety of a rescue station in very long rail tunnel in Korea. Tunnelling and Underground Space Technology. 2006; 21:303.10.1016/j.tust.2005.12.159 ↗
6. Tarada F, Bopp R, Nyfeler S (2000) Ventilation and risk control of the Young Dong Rail Tunnel in Korea. 1st international conference on major tunnel and infrastructure projects, Taiwan
7. Tarada F (2000) Critical velocities for smoke control in tunnel cross-passages. 1st international conference on major tunnel and infrastructure projects, Taiwan
8. Y. Z. Li, B. Lei. Model of critical velocity in a tunnel cross-passage. Journal of the China Railway Society. Beijing: 2008, 30(3):87-90.
9. J. G. Quintiere, Scaling application in fire research. Fire Safety Journal.1989; 15:3-29.10.1016/0379-7112(89)90045-3 ↗
10. G. Heskestad. Modeling of enclosure fires. 14th symposium on combustion. The Combustion Institute, University Park, PA, 1972. pp 1021-1030.
11. Saito N, Yamada T, Sekizawa A, Yanai E, Watanabe Y, Miyazaki S (1995) Experimental study on fire behavior in a wind tunnel with a reduced scale model. In: Second international conference on safety in road and rail tunnels, Granada, Spain, April 1995, pp 303–310
12. G. Heskestad. Physical modeling of fire. Journal of Fire and Flammability. 1975; 6:253-273.
13. H. Ingason. Model scale railcar fire tests. Fire Safety Journal. 2007; 42:271-282.10.1016/j.firesaf.2006.11.004 ↗
14. H. Ingason. Model scale tunnel tests with water spray system. Fire Safety Jounal. 2008; 43: 512-528.10.1016/j.firesaf.2007.12.002 ↗