Heat Release Rate of Heavy Goods Vehicle Fire in Tunnels with Fixed Water Based Fire-Fighting System
Source abstract
Abstract
A series of large-scale fire tests for road tunnel application was conducted in a test tunnel facility in Spain. The aim of this fire tests program was to investigate the magnitude of the heat release rate generated by a fire in heavy goods vehicles (HGV’s) with and without a fire suppression system in tunnels in Singapore; the possibility of interchanging a fire suppression system with other measures such as lowering the longitudinal flow velocity; and to acquire information on the appropriate design parameters (e.g., nozzle type, discharge density and activation time) to adopt based on the most probable fuel load used in these road tunnels. In order to ensure repeatability, simulated HGV’s consisting of 228 pallets with 48 plastic pallets (20%) and 180 wooden pallets (80%) were used in all fire tests. An air velocity of approximately 3 m/s was applied. As the scope of work covered in this fire test program is very large, only the setup of the fire test and the findings on the effects of heat release rate with (Test 4) and without (Test 7) a fixed water based fire-fighting system are covered. The test results indicate that a substantial reduction of fire heat release rate can be obtained using a low-pressure deluge fire suppression system, as long as timely activation of the water is provided. However, the influence of the suppression system on CO production is significant. Such experimental data address the current dearth of knowledge on the actual effect of low-pressure deluge systems on the heat release rate from HGVs in tunnel fires.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Fire Detection and Safety Systems · Fire effects on ecosystems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Ingason H, Lönnermark A (2005) Heat release rates from heavy goods vehicle trailer fires in tunnels. Fire Saf J 40:646–66810.1016/j.firesaf.2005.06.002 ↗
2. Studiengesellschaft Stahlanwendung e.V Dusseldorf (1995) Fire in transport tunnels—report on full-scale tests, EUREKA-Project EU 499: FIRETUN
3. Tunnel safety testing (TST) Web-site http://www.tunneltest.com/ingles/tunelensayo.php . Accessed 13 July 2012
4. Implementation of vehicle immobiliser system in Phase 2 of the Hazmat Transport Vehicle Tracking System, Singapore Civil Defence Force, Jan 2007
5. Singapore Gazette, Road Traffic Act 2006, Chapter 276, Sections 114 and 140, Road Traffic Expressway Traffic Rules, June 2006
6. Dlugogorski BZ, Mawhinney JR, Huu Duc V (1994) The measurement of heat release rates by oxygen consumption calorimetry in fires under suppression. Fire Saf Sci 4:877–888. doi: 10.3801/IAFSS.FSS.4-87710.3801/IAFSS.FSS.4-877 ↗
7. Parker WJ (1982) Calculation of the heat release rate by oxygen consumption for various applications, U.S. Department of Commerce, National Bureau of Standards, NBSIR 81-2427, 1–38, Feb 198210.6028/NBS.IR.81-2427-1 ↗
8. Meeussen VJA et al (2008) The effect of a water mist system on large-scale tunnel fires. Proceedings of the ITA COSUF workshop on safety and security of railway and metro tunnels, Graz, Austria, 23 Apr 2008